My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2007 - 2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DUCK CREEK
>
3633
>
2300 - Underground Storage Tank Program
>
PR0232461
>
COMPLIANCE INFO 2007 - 2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:11 PM
Creation date
11/4/2018 3:46:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007 - 2010
RECORD_ID
PR0232461
PE
2361
FACILITY_ID
FA0003758
FACILITY_NAME
RYDER TRUCK RENTAL #1071
STREET_NUMBER
3633
STREET_NAME
DUCK CREEK
STREET_TYPE
DR
City
STOCKTON
Zip
95215
APN
17331001
CURRENT_STATUS
01
SITE_LOCATION
3633 DUCK CREEK DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DUCK CREEK\3633\PR0232461\COMPLIANCE INFO 2007 - 2010.PDF
QuestysFileName
COMPLIANCE INFO 2007 - 2010
QuestysRecordDate
4/25/2018 11:45:33 PM
QuestysRecordID
3869854
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
277
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
M©NITING SYSTEM CERTIFICATION <br />se By All Jurisdictions Within the State of Califo.mi <br />Authority Cited: Chapter 6.7, Heath and Safety Code; Chapter 16, Division 3 Title 23, aria Code of Regulations <br />This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility, a separate <br />certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br />system owner/operator. The ownerloperator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility Name: RYDER 1071A <br />Site Address: 3633 DUCK CREEK DRIVE <br />City: STOCKTON CA Zip: 95215 <br />Contact Phone No: 943-3213 <br />Date of Testing/Service: 02/21/2007 <br />Facility Contact Person: MARK ARMSTRONG <br />Make/Model of Monitoring System: SIMPLICITY Work Order Number: 2247471 <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicate specific equipment inspected/serviced <br />Tank ID: DSL -1 <br />4�"�f <br />Tank ID: DSL -2 <br />X In -Tank Gauging Probe. <br />Model: MAG -1 <br />ZI In -Tank Gauging Probe. <br />Model: MAGA <br />X Annular Space or Vault Sensor. <br />Model: 420 <br />21 Annular Space or Vault Sensor. <br />Model: 420 <br />X Piping Sump/Trench Sensor(s). <br />Model: 208 <br />Piping Sump/Trench Sensor(s). <br />Model: 208 <br />X Fill Sump Sensor(s). <br />Model 208 <br />Fill Sump Sensor(s). <br />Model: 208 <br />X Mechanical Line Leak Detector. <br />Model: LD2000 <br />)( Mechanical Line Leak Detector. <br />LD2000 <br />Model: _ <br />Electronic Line Leak Detector. <br />Model: <br />Electronic Line Leak Detector. <br />Model: <br />X Tank Overfill/High-Level Sensor. <br />Model: ANNUNCIATOR <br />Tank OvefIlfHigh-Level Sensor. <br />Model: ANNUNCIATOR <br />Other (specify equipment type and <br />model in Section E on page 2). <br />Other (specify equipment type and model in Section E on page 2). <br />Tank ID: <br />Tank ID: <br />In -Tank Gauging Probe. <br />Model: MAGA <br />In -Tank Gauging Probe, <br />Model: MAG -1 <br />X Annular Space or Vault Sensor. <br />Model: 420 <br />71 Annular Space or Vault Sensor. <br />Model: 420 <br />X Piping Sump/Trench Sensor(s), <br />Model: 208 <br />X Piping Sump/Trench Sensor(s). <br />Model: 208 <br />X Fill Sump Sensor(s). <br />Model: 208 <br />X Fill Sump Sensor(s). <br />Model: 208 <br />Mechanical Line Leak Detector. <br />Model: <br />Mechanical Line Leak Detector. <br />Model: <br />Electronic Line Leak Detector. <br />Model: <br />Electronic Line Leak Detector. <br />Model: <br />Tank OverfilllHigh-Level Sensor. <br />Model: ANNUNCIATOR <br />Tank Overfill/High-Level Sensor. <br />Model: <br />Other (specify equipment type and <br />model in Section E on page 2). <br />Other (specify equipment type and model in Section E on page 2). <br />Dispenser : 112 <br />Dispenser ID: 314 <br />X❑ Dispenser Containment Sensor(s) <br />Model: 208 <br />X Dispenser Containment Sensor(s) <br />Model: 208 <br />X� Shear Valve(s). <br />X Shear Valve(s) <br />ElDispenser Containment Float(s) and Chain(s). <br />Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 1 -SLAVE <br />Dispenser ID: 2 -SLAVE <br />0 Dispenser Containment Sensor(s) <br />Model: 208 <br />Q Dispenser Containment Sensor(s). <br />Model: 208 <br />ElShear Valve(s). <br />Shear Valve(s). <br />Dispenser Containment Float(s) and Chain(s). <br />Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 4 -SLAVE <br />Dispenser ID: <br />X❑ Dispenser Containment Sensor(s) <br />Model: 208 <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />® Shear Valve(s). <br />Shear Valve(s). <br />Dispenser Containment Float(s) and Chain(s). <br />Dispenser Containment Float(s) and Chain(s). <br />If the facility contains more tanks or dispensers, copy this form. include Intormatlon Tor every tanK ano olspenser at the racmty. <br />C. Certification <br />I certify that the equipment identified in this document was inspectedlserviced in accordance with the manufacturers' guidelines. <br />Attached to this certification is information (e.g manufacturers' checklists) necessary to verify that this information is correct. <br />and a Site Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached <br />a copy of the (Check all that apply): FX system set-up XD Alarm history report <br />Technician Name (print): HEATH MCEVER <br />Certification No.: A27562 <br />Signature: <br />4�"�f <br />License. No.: <br />Testing Company Name:Tanknology Phone No.: (800) 8004633 <br />Site Address: 8501 N. MoPac Expressway, suite 400, Austin, TX 78759 Date of Testing/Servicing: 02/21/2007 <br />Page 1 of 3 Based on CA form dated 03101 <br />Monitoring System Certification <br />
The URL can be used to link to this page
Your browser does not support the video tag.