Laserfiche WebLink
CALIFORNIA MONTHLY <br />STATISTICAL INVENTORY RECONCILATION (SIR) REPORT <br />SIR Provider ETL Southwest I Phone (602) 837-8738 <br />IR VersionSIRAS — version 2.6.3 IDate of SIR report 11/16/95 <br />_�emS,;r:Period Covered - 10/95 _ What is the required number of usable inventory days per tank? 30 <br />Unocal No. 4409 <br />v 1502 N. EI Dorado <br />32 Stockton, CA 95204 <br />ACILITYNAME <br />Unocal No. 4409 <br />TANK <br />tt LOCATION <br />Address 1502 N. EI Dorado <br />City Stockton <br />Phone (714) 572-7653 <br />Zip 95204 <br />NK OWNER <br />F <br />Name Unocal <br />Address 2929 E. Imperial Highway <br />City Brea =Phone (714) 572-7653 <br />K,OPERATOR <br />Name Unocal Phone (714) 572-7653 <br />umber <br />RL <br />Tank <br />Contents <br />- <br />_ <br />Tank <br />Capacity <br />(gallons) <br />- <br />This Month <br />Last <br />Month (7) <br />Two <br />Months <br />Ago (7) <br />Leak Minimum <br />Threshold Detectable <br />Leak Rate (6c) <br />Calculated Pass, Fall, <br />Leak Rate (6b) Inconclusive <br />Pass, Fall, <br />Inconclusive <br />Pass, Fall, <br />Inconclusive <br />gph gph <br />gph P F I <br />P F I <br />P F <br />Tank No. 67-1 <br />Regular Unleaded <br />12000 <br />0.10 0.20 <br />-0.01 ' <br />Tank No. 92-1 <br />Premium Unleaded <br />12000 <br />0.10 0.20 <br />-0.04 <br />Tank No. DSL -1 <br />Diesel <br />12000 <br />0.10 0.20 <br />-0.02 ' <br />NOTE: WA indicates No Analysis Performed Negative Calculated Leak Rates indicate a Gain <br />1. The tank owner is required to have an SIR report for each month [Section 2643 (b)(3) CCR']. <br />2. Monthly reports must be submhted to the local agency upon request [Section 2712 (b) CCR]. <br />3. The tank owner is required to have the report by the 20th day of the following month [Section 2646.1 (c) CCR]. <br />4. If for any reason, the lest is neither "pass" nor "fail, the "inconclusive column must be marked. <br />5. The k cal agency must be notified of a tank that does not pass the SIR test within 24 hours of receipt of the report and the SIR report must be <br />submitted to the local agency within 10 days of the dale of the report [Section 2646.1 (d) CCR]. <br />6. Quantitative and Qualitative Methods: <br />a. A leak threshold, minimum detectable leak rate, and calculated leak rate must be provided for each tank. If net, then the tank failed the SIR test. <br />b. If the calculated leak rate for a tank is greater than or equal to the leak threshold, the tank failed the SIR test. <br />c. If the minimum detectable leak rate for a tank Is greater than the certified performance standard (i.e., 0.1 or 0.2 gph) and the calculated leak rate <br />is less than the leak threshold, the lest is inconclusive for that month. <br />d. Two consecutive failures and/or inconclusives require a tank and/or piping integrity lest within 15 days from the date of the <br />second report [Section 2646.1 (h) CCR]. <br />7. Optional. <br />conducting evaluation <br />I "Signature (optional) I CERTIFICATE # UT0225 I Date it lltrm- <br />CCR means Title 23, Division 3, Chapter 16 of the California Code of Regulations <br />SWRCB—SiRM10N-01 (12/94) <br />