Laserfiche WebLink
CALIFORNIA MONTHLY <br />STATISTICAL INVENTORY RECONCILATION (SIR) REPORT <br />SIR Provider ETL Southwest Phone (602) 837-8738 <br />SIR Version SIRAS — version 2.8.3 Date of SIR report 10/10/95 <br />. PSP/od.Covered -'.. 9/95 What is the required number of usable inventory days per lank? 15 <br />Unocal No. 4409 <br />0 1502 N. EI Dorado <br />a <br />Stockton, CA 95204 <br />Unocal No. <br />4409 <br />Address <br />1502 N. EI Dorado <br />City <br />Stockton <br />Phone <br />(714) 572-7653 <br />Zip <br />95204 <br />Name <br />Address <br />Unocal <br />2929 E. Imperial Highway <br />City <br />Brea <br />Phone <br />(714) 572-7653 <br />Name <br />Unocal <br />Phone <br />(714) 572-7653 <br />PTank <br />Leak <br />Threshold <br />gph <br />This Month <br />Minimum Calculated Pass, Fail, <br />Detectable Leak Rate (6b) Inconclusive <br />Leak Rate (6c) <br />gph gph P F I <br />Last <br />Month (7) <br />Pass, Fell, <br />Inconclusive <br />P F I <br />Two <br />Months <br />Ago (7) <br />Pass, Fail, <br />Inconclusive <br />P F I <br />87-1 Regular Unleaded <br />12000 0.10 <br />0.32 <br />-0.04 <br />• <br />* <br />` <br />92-1 Premium Unleaded <br />12000 0.10 <br />0.18 <br />0.00 <br />DSL -1 Diesel <br />12000 0.10 <br />0.20 <br />0.05 <br />' <br />NOTE: N/A indicates No Analysis Performed Negative Calculated Leak Rates indicate a Gain <br />1. The tank owner is required to have an SIR report for each month [Section 2643 (b)(3) CCR']. <br />2. Monthly reports must be submitted to the local agency upon request [Section 2712 (b) CCR]. <br />3. The tank owner is required to have the report by the 20th day of the following month [Section 2646.1 (c) CCR]. <br />4. If for any reason, the lest is neither "pass' nor "fail", the "inconclusive column must be marked. <br />5. The local agency must be notified of a tank that does not pass the SIR test within 24 hours of receipt of the report and the SIR report must be <br />submitted to the local agency within 10 days of the date of the report [Section 2646.1 (d) CCR]. <br />6. Quantitative and Qualitative Methods: <br />a. A leak threshold, minimum detectable leak rate, and calculated leak rate must be provided for each tank. If not, then the tank failed the SIR test. <br />b. If the calculated leak rate for a tank is greater than or equal to the leak threshold, the tank failed the SIR test. <br />c. If the minimum detectable leak rate for a tank is greater than the certified performance standard (i.e., 0.1 or 0.2 gph) and the calculated leak rate <br />is less than the leak threshold, the lest is inconclusive for that month. <br />d. Two consecutive failures and/or inwriclusives require a tank and/or piping integrity test within 15 days from the date of the <br />second report [Section 2646.1 (h) CCR]. <br />7. Optional. _ <br />CCR mare Tide 23. DiMeion 3. Chapter 16 of the California Code of Regulations <br />SWRCB—SIRIMON-01 (12/94) <br />