COMPLIANCE INFO 1998-2004
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
153
>
2300 - Underground Storage Tank Program
>
PR0231389
>
COMPLIANCE INFO 1998-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
11/4/2018 4:31:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2004
RECORD_ID
PR0231389
PE
2361
FACILITY_ID
FA0003709
FACILITY_NAME
VALERO #3698
STREET_NUMBER
153
Direction
E
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23336607
CURRENT_STATUS
01
SITE_LOCATION
153 E ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\ELEVENTH\153\PR0231389\COMPLIANCE INFO 1998-2004.PDF
QuestysFileName
COMPLIANCE INFO 1998-2004
QuestysRecordDate
5/19/2017 4:43:15 PM
QuestysRecordID
3389407
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
200
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • Page of <br /> 7. UNDER-DISPENSER CONTAINMENT(UDQ TESTING <br /> Test Method Developed By: ❑UDC Manufacturer X Industry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Uses: ❑Pressure ❑Vacuum X Hydrostatic <br /> ❑Other(Spec6) <br /> Measuring Equipment Used for Testing: UST 2000P <br /> UDC#1/2 UDC#3/4 UDC#5/6 <br /> UDC Manufacturer: BRAVO BRAVO BRAVO <br /> UDC Material: STEEL STEEL STEEL <br /> UDC Depth: 14" 14" 14" <br /> Height from UDC Bottom to Bottom of Box Bottom of Box Bottom of Box <br /> Highest Piping Penetration: <br /> Height from UDC Bottom to Bottom of Box Bottom of Box Bottom of Box <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to FAIR FAIR FAIR <br /> testing: <br /> Portion of UDC Tested ENTIRE BOX ENTIRE BOX ENTIRE BOX <br /> Wait time between applying @10 MIN @10 MIN @10 MIN <br /> pressure/vacuum/water and starting <br /> test: <br /> Test Start Time: 0840 0854 0936 <br /> Initial Reading(Rt): .2858 .8740 .5585 <br /> Test End Time: 0846 0900 0942 <br /> Final Reading(RF): .2860 .8743 .5584 <br /> Test Duration: 6MIN 6MIN 6MIN <br /> Change in Reading F-R, : +.0002 +.0003 -.0001 <br /> Pass/Fail Threshold: +/-.001 +/-.001 +/-.001 <br /> Test Result: PASS PASS PASS <br /> Was sensor removed for YES YES YES <br /> testing? <br /> Was sensor properly replaced YES YES YES <br /> after testing? <br /> Comments—(include information on repairs made prior to testing) <br /> SWRCB December 2001 <br />