2300 - Underground Storage Tank Program
>
PR0231389
>
COMPLIANCE INFO 1998-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
11/4/2018 4:31:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2004
RECORD_ID
PR0231389
PE
2361
FACILITY_ID
FA0003709
FACILITY_NAME
VALERO #3698
STREET_NUMBER
153
Direction
E
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23336607
CURRENT_STATUS
01
SITE_LOCATION
153 E ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\ELEVENTH\153\PR0231389\COMPLIANCE INFO 1998-2004.PDF
QuestysFileName
COMPLIANCE INFO 1998-2004
QuestysRecordDate
5/19/2017 4:43:15 PM
QuestysRecordID
3389407
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
200
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDA TANK INFORMATION AN EST RESULTS <br /> TEST DATE:02/07/02 8900 SHOAL CREEK,BUILDING 200 WORKORDER NUMBER2220769 <br /> AUSTIN,TEXAS 78757(512)451-6334 SITE:ALTAAMAR 698 <br /> CLIENT:ULTRAMAR INC <br /> _, <br /> Tank ID: #3 1 Tank manifolded: No Bottom to top fill in inches: 133.5 <br /> Product: suPREME Vent manifolded: yEs Bottom to grade in inches: 141.0 <br /> Vapor recovery manifolded: yEs Fill pipe length in inches: 37.5 <br /> Capacity in gallons: 196.00 P ry Fill pipe diameter in inches: 4.0 <br /> Diameter in inches: 96.00 Overfill protection: yEs P P <br /> Length in inches: 328 P <br /> Overspill protection: yEs Stage I vapor recovery: DUAL <br /> Stage II vapor recovery: ASSIST <br /> Material: DW STEEL Installed: ATG <br /> CP installed on: <br /> COMMENTS <br /> DETECTOR TEST R <br /> Ia <br /> a m n m Newlpassed Failed/replaced New/passed Failedlreplac6 <br /> Dipped Water Level: L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> Dipped Product Level: Make: RED JACKET <br /> Probe Water Level: Model: FK1V <br /> Ingress Detected: Water Bubble Ullage S/N: 104011906 <br /> Test time: Open time in sec: 1.00 <br /> Inclinometer reading: Holding psi: 17 <br /> Resiliency in ml: 70 NOT <br /> VacuTect Test Type: NOT TESTED <br /> p <br /> VacuTect Probe Entry Point: TESTED est leak rate mlsi: 1s <br /> 1Sa.o <br /> Pressure Set Point: Metering psi <br /> Tank water level in inches: Calib. leak in gph: 3.00 <br /> Water table depth in inches: <br /> Results: PASS <br /> Determined by(method): COMMENTS <br /> Result: <br /> COMMENTS <br /> a ; <br /> Material: DW FIBERG <br /> Impact Valves Operational:yES Diameter(in): 2.0 <br /> Length(ft): 60.0 <br /> COMMENTS Test psi: 60 <br /> Bleedback cc: 0 <br /> Test time (min): 30 <br /> Test 1:Start time: 10:06 <br /> Finish psi: o NOT NOT NOT <br /> Vol change cc: 110 TESTED TESTED TESTED <br /> Test 2:Start time: 10:2, <br /> Finish psi: 0 <br /> Vol change cc: 110 <br /> IL Test 3:Start time: 10:38 <br /> Finish psi: 0 <br /> Vol change cc: 110 <br /> Final gph: 0.174 <br /> Result: FAIL <br /> Pump type: PRESSURE <br /> Pump make: RED JACKET <br /> Printed 02111/2002 1 7:11 SBOWERI <br />