My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1998-2004
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
153
>
2300 - Underground Storage Tank Program
>
PR0231389
>
COMPLIANCE INFO 1998-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
11/4/2018 4:31:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2004
RECORD_ID
PR0231389
PE
2361
FACILITY_ID
FA0003709
FACILITY_NAME
VALERO #3698
STREET_NUMBER
153
Direction
E
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23336607
CURRENT_STATUS
01
SITE_LOCATION
153 E ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\ELEVENTH\153\PR0231389\COMPLIANCE INFO 1998-2004.PDF
QuestysFileName
COMPLIANCE INFO 1998-2004
QuestysRecordDate
5/19/2017 4:43:15 PM
QuestysRecordID
3389407
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
200
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVID TANK INFORMATION AN EST RESULTS <br /> I`.raM "0109Y <br /> TEST DATE:02/07/02 8900 SHOAL CREEK,BUILDING 200 WORK ORDER NUMBER2220769 <br /> AUSTIN,TEXAS 78757(512)451-6334 SITE:ULTRAMAR 698 <br /> CLIENT:VLTRAM11 AR INC jil'jil 115 1 :1,11:1111 icrilliluwwwffi—�� IF, <br /> 4 <br /> Tank ID: #1 - MAI 2 Tank manifolded: YES Bottom to top fill in inches: 137.5 <br /> Product: UNLEADED Vent manifolded: YES Bottom to grade in inches: 146.0 <br /> Vapor recovery manifolded:YES Fill pipe length in inches: 41.5 <br /> Capacity in gallons: 10,152 P <br /> Diameter in inches: 96.00 Overfill protection:YES Fill pipe diameter in inches: 4.o <br /> Overspill protection:YES Stage 1 vapor recovery: DUAL <br /> Length in inches: 328 P p Stage II vapor recovery: Ass1sT <br /> Material: Dw STEEL Installed: ATG <br /> CP installed on: <br /> COMMENTS <br /> m n m New/passed Failedlreplaced Newlpassed Fadedlreplacc <br /> N Dipped Water Level: L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> Dipped Product Level: Make: RED JACKET <br /> Probe Water Level: Model: Fx1v <br /> Ingress Detected: Water Bubble UllageS/N: 212003502 <br /> Test time: Open time in sec: 3.00 <br /> Inclinometer reading: Holding psi: 14 <br /> Resiliency in ml: 65 NOT <br /> VacuTect Test Type: NOT TESTED <br /> est leak rate ml/m: 1e9.0 <br /> VacuTect Probe Entry Point: TESTED Metering psi: 13 <br /> Pressure Set Point: Calib. leak in gph: 3.00 <br /> Tank water level in inches: Results: PASS <br /> Water table depth in inches: <br /> Determined by(method): COMMENTS <br /> Result: <br /> COMMENTS <br /> ,LENS.. <br /> 3' <br /> Material: DW FIBERG <br /> Impact Valves Operational: YES Diameter(in): 2.0 <br /> Length(ft): 60.0 <br /> COMMENTS Test psi: 60 <br /> Bleedback cc: 105 <br /> Test time(min): 30 <br /> Test 1:Start time: 10:03 <br /> Finish psi: so NOT NOT NOT <br /> Vol change cc: 17 TESTED TESTED TESTED <br /> Test 2:Start time: 10;14 <br /> Finish psi: 52 <br /> Vol change cc: 1s <br /> Test 3: Start time: 10:25 <br /> Finish psi: 54 <br /> Vol change cc: 11 <br /> Final gph: 0.023 <br /> Result: PASS <br /> Pump type: PRESSURE <br /> Pump make: RED JACKET <br /> Printed 021111200217:11 SBOWER <br />
The URL can be used to link to this page
Your browser does not support the video tag.