Laserfiche WebLink
Ah <br />Ah <br />INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br />1 - <br />PIP TanlaxWogy <br />8900 SHOAL CREEK, BUILDING 200 <br />TEST DATE: 02/10/04 <br />AUSTIN, TEXAS 78757 (512) 451-6334 WORK ORDER NUMBER: 2229924 <br />CLIENT: VALERO <br />SITE: ULTRAMAR 698 (VALERO) <br />.. <br />TANKINFORMATION'. <br />Tank ID: #3 1 <br />Tank manifolded: NO Bottom to top fill in inches: 133.5 <br />Product: SUPREME <br />Vent manifolded: YES Bottom to grade in inches: 141.0 <br />Capacity in gallons: 10,152 <br />Vapor recovery manifolded: YES Fill pipe length in inches: 37.5 <br />Diameter in inches: 96.00 <br />Overfill protection: YES Fill pipe diameter in inches: 4.0 <br />Length in inches: 328 <br />Overspill protection: YES Stage I vapor recovery: DUAL <br />Material: DW STEEL <br />Installed: ATG Stage II vapor recovery: ASSIST <br />CP installed on: <br />COMMENTS <br />FANt TESTRESULfiSr ' esEMethod_vPIT';ru;*:3_ .._ <br />"LEAKDETECTOR,TESfRESU4TS^;� , „;aTL'St m2fhOS(FTII---=_ <br />PSI at tank bottom: <br />New/passed Failed/replaced New/passed Failed/replaced <br />Fluid level in inches: <br />L.D. #1 L.D. #1 L.D. #2 L.D. #2 <br />UFT/OFT: <br />Make: RED JACKET <br />Fluid volume in gallons: <br />Model: Fx1V <br />Tank water level in inches: <br />S/N: 104011000 <br />Test time: <br />NOT <br />Open time in sec: 3.00 <br />Number of thermisters: <br />TESTED <br />Holding psi: 19 NOT <br />Specific gravity: <br />Resiliency cc: 110 TESTED <br />Water table depth in inches: <br />Test leak rate ml/m: 189.0 <br />Determined by (method): <br />Metering psi: 14 <br />Leak rate in gph: <br />Calib. leak in gph: 3.00 <br />Result: <br />Results: PASS <br />COMMENTS <br />COMMENTS <br />ULLAGE.TEST<RSULTS- t<Me�I75XkUTS"T.; <br />LINE�TEST-.RESULTS,w.`� <br />$St tjtper PT 8e- '2 4= <br />Test time: <br />Material: DW FIBERG <br />Ullage volume: <br />Diameter (in): 2.0 <br />Ullage pressure: <br />Length (ft): 150.0 <br />Results: <br />Test psi: 50 <br />Bleedback cc: 140 <br />Test time (min): 30 <br />DATA FOR LITS -4T ONLY: <br />Test 1: Start time: 11:10 <br />Time of test 1: <br />Finish psi: 50 NOT NOT NOT <br />Temperature: <br />NOT <br />Vol change cc: a TESTED TESTED TESTED <br />Test 2: Start time: 11:20 <br />Flow rate (cfh): TESTED <br />Finish psi: 50 <br />Time of test 2: <br />Vol change cc: o <br />Test 3: Start time: 11:30 <br />Temperature: <br />Finish psi: so <br />Flow rate (cfh): <br />Vol change cc: o <br />Time of test 3: <br />Final gph: 0.000 <br />Temperature: <br />Result: PASS <br />Flow rate (cfh): <br />Pump type: PRESSURE <br />COMMENTS <br />Pump make: RED JACKET <br />COMMENTS Impact Valves Operational: YES <br />11 1 <br />Printed 02/12/2004 08:49 SBOWERS <br />