My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1998-2004
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
153
>
2300 - Underground Storage Tank Program
>
PR0231389
>
COMPLIANCE INFO 1998-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
11/4/2018 4:31:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2004
RECORD_ID
PR0231389
PE
2361
FACILITY_ID
FA0003709
FACILITY_NAME
VALERO #3698
STREET_NUMBER
153
Direction
E
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23336607
CURRENT_STATUS
01
SITE_LOCATION
153 E ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\ELEVENTH\153\PR0231389\COMPLIANCE INFO 1998-2004.PDF
QuestysFileName
COMPLIANCE INFO 1998-2004
QuestysRecordDate
5/19/2017 4:43:15 PM
QuestysRecordID
3389407
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
200
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ah <br />14W MW <br />INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br />go <br />i Tanknology <br />TEST DATE: 02/10/04 <br />8900 SHOAL CREEK, BUILDING 200 WORK ORDER NUMBER: 2229924 <br />AUSTIN, TEXAS 78757 (512) 451-6334 <br />CLIENT: VALERO <br />SITE: ULTRAMAR 696 (VALERO) <br />TANKINFORMATION --•' ' '""- <br />Tank ID: #1 - NAI 2 <br />Tank manifolded: YES Bottom to top fill in inches: 137.5 <br />Product: UNLEADED <br />Vent manifolded: YES Bottom to grade in inches: 146.0 <br />Capacity in gallons: 10,152 <br />Vapor recovery manifolded: YES Fill pipe length in inches: 41.5 <br />Diameter in inches: 96.00 <br />Overfill protection: YES Fill pipe diameter in inches: 4.0 <br />Length in inches: 328 <br />Overspill protection: YES Stage I vapor recovery: DUAL <br />Material: DW STEEL <br />Installed: ATG Stage II vapor recovery: ASSIST <br />CP installed on: <br />COMMENTS <br />FpNKTEST SULTS_.y''nT Mefhed"YBi9T-` 44"„ <br />i_ LE*DETECTO,R'.TES.T <br />PSI at tank bottom: <br />New/passed Failed/replaced New/passed Failed/replaced <br />Fluid level in inches: <br />L.D. #1 L.D. #1 L.D. #2 L.D. #2 <br />UFT/OFT: <br />Make: RED JACKET <br />Fluid volume in gallons: <br />Model: FX1V <br />Tank water level in inches: <br />S/N: 21003502 <br />Test time: <br />NOT <br />Open time in sec: 3.00 <br />Number of thermisters: <br />,TESTED <br />Holding psi: 18 NOT <br />Specific gravity: <br />Resiliency cc: 90 TESTED <br />Water table depth in inches: <br />Test leak rate ml/m: 189.0 <br />Determined by (method): <br />Metering psi: 14 <br />Leak rate in gph: <br />Calib. leak in gph: 3.00 <br />Result: <br />Results: PASS <br />COMMENTS <br />COMMENTS <br />ULLAS;E`.i'E5T RESTS?Test Method i1TS 4T,' <br />UL <br />LIN <br />Test B` EdislExeR= _ - 2 <br />E ST RESULT <br />Test time: <br />Material: DW PIBERG <br />Ullage volume: <br />Diameter (in): 2.0 <br />Length (ft): 150.0 <br />Ullage pressure: <br />Test psi: 50 <br />Results: <br />Bleedback cc: 125 <br />Test time (min): 30 <br />DATA FOR UTS4T ONLY: <br />Test 1: Start time: 11:10 <br />Time of test 1: <br />Finish psi: 50 NOT NOT NOT <br />Temperature: <br />NOT <br />Vol change cc: 0 TESTED TESTED TESTED <br />Test 2: Start time: 11:20 <br />Flow rate (cfh): <br />TESTED <br />Finish psi: 50 <br />Time of test 2: <br />Vol change cc: 0 <br />Test 3: Start time: 11:30 <br />Temperature: <br />Finish psi: 50 <br />Flow rate (cfh): <br />Vol change cc: 0 <br />Time of test 3: <br />Final gph: 0.000 <br />Temperature: <br />Result: PASS <br />Flow rate (cfh): <br />Pump type: PRESSURE <br />Pump make: RED JACKET <br />COMMENTS <br />COMMENTS Impact Valves Operational: YES <br />Printed 02/12/2004 08:49 SBOWERS <br />