My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2005-2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
153
>
2300 - Underground Storage Tank Program
>
PR0231389
>
COMPLIANCE INFO 2005-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
11/4/2018 4:32:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2011
RECORD_ID
PR0231389
PE
2361
FACILITY_ID
FA0003709
FACILITY_NAME
VALERO #3698
STREET_NUMBER
153
Direction
E
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23336607
CURRENT_STATUS
01
SITE_LOCATION
153 E ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\ELEVENTH\153\PR0231389\COMPLIANCE INFO 2005-2011.PDF
QuestysFileName
COMPLIANCE INFO 2005-2011
QuestysRecordDate
5/19/2017 6:00:47 PM
QuestysRecordID
3389699
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
372
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
8. Fill Riser Containment Sump Testing <br /> Test Method Developed By: ❑Tank Manufacturer Industry Standard ❑Professional Engineer <br /> Test Method Used: ❑Pressure <br /> ❑Vacuum ❑JC Hydrostatic <br /> Test Equipment Used: Incon TS STS Leak Detector Equipment Resolution:t0.002 <br /> Fill Sump# 87A Fill Sump# 87B Fill Sump# 91 FIII Sump# <br /> Sump Diameter: 48" 48" 48" <br /> Sump Depth: 27" 27" -- 28" <br /> Height from Tank Top to Top of 12" 11" <br /> Highest Piping Penetration: 14" <br /> Height from Tank Top to <br /> Lowest Electrical Penetration: 19" 23" 14" <br /> Condition of sump prior to <br /> testing: Ok Ok Ok <br /> Portion of Sump Tested: 100% 100%, 100% <br /> Sump Material: Fiberglass Fiberglass Fiberglass <br /> Wait time: 15 min 15 min 15 min <br /> Test StartTime: 11:02 am 11:02 am 11:02 am <br /> Initial Reading: 5.0160 4.4751 5.1295 <br /> Test End Time: 11:17 am 11:17 am 11:17 am <br /> Final Reading: _5.0168 4.4758 5.1309 <br /> Test Duration(hh:mm): 00:15 00:15 00:15 00:00 <br /> Change in Reading: 0.0008 0.0007 0.0014 0.0000 <br /> Pass/Fail Threshold or Criteda: 10.002 10.002 ±0.002 ;1:0.002 <br /> Pass. Fail Pass 0 Fail <br /> Pass Fail 0 Pass 0 Fail <br /> Is there a sensor in the sump? Yes Yes Yes <br /> Does the sensor alarm when <br /> either product or water is N/A WA WA <br /> detected? <br /> Was sensor removed for <br /> testing? ®Yes No NA ®Yes No 0 NA ®Yes 0 No 0 NA 0 Yes 0 No 0 NA <br /> Was sensor properly replaced <br /> and verified functional after *Yes 0 No 0 NA *Yes 0 No 0 NA ®Yes 0 No 0 NA 0 Yes 0 No 0 NA <br /> testing? <br /> Comments: <br /> 6 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.