COMPLIANCE INFO 2005-2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
153
>
2300 - Underground Storage Tank Program
>
PR0231389
>
COMPLIANCE INFO 2005-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
11/4/2018 4:32:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2011
RECORD_ID
PR0231389
PE
2361
FACILITY_ID
FA0003709
FACILITY_NAME
VALERO #3698
STREET_NUMBER
153
Direction
E
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23336607
CURRENT_STATUS
01
SITE_LOCATION
153 E ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\ELEVENTH\153\PR0231389\COMPLIANCE INFO 2005-2011.PDF
QuestysFileName
COMPLIANCE INFO 2005-2011
QuestysRecordDate
5/19/2017 6:00:47 PM
QuestysRecordID
3389699
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
372
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page 2 of 7__ <br /> T. UNDER-DISPENSER CONTAINMENT C TESTING <br /> Test Method Developed By: D UDC Manufacturer Crindustry Standard ❑Professional Engineer <br /> D Other(Specify) <br /> Test Method Used: D Pressure D Vacuum Hydrostatic <br /> D Other(S)7ecj&) <br /> Test Equipment Used: 'JIMCO h Equipment Resolution:10. O 6't_ <br /> UDC# (' Z UDC# UDC# 5- UDC# <br /> UDC Manufacturer: v a <br /> UDC Material: c e <br /> UDC Depth: 4 <br /> Height from UDC Bottom to Top �( <br /> of Highest Piping Penetration: (/7 <br /> Height from UDC Bottom to <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to <br /> testing: ti K <br /> Portion of UDC Tested <br /> Does turbine shut down when Dyes ❑No IRNA <br /> UDC sensor detects liquid(both D Yes DNo E4NA D Yes DNo aNA D Yes DNo DNA <br /> product and water)? <br /> Turbine shutdown response time <br /> Is system programmed for fail- Yes D No D NA QLYes DNo DNA KYes DNo DNA C Yes D No D NA <br /> safe shutdown?. <br /> Was fail-safe verified to be 6-Yes D No D NA &,es DNo [INA gVes C No DNA D Yes DNo DNA <br /> o erational?* <br /> Wait time between applying <br /> pressure/vacuum/water and 'syy,l h <br /> starting test <br /> Test Start Time: O Z <br /> Initial Reading •Q $ . S S I <br /> Test End Time: <br /> Final Reading(R,): OS 73,Ml <br /> 5l <br /> Test Duration: : � WI i.. <br /> Change in Reading F-Ri : - p.Ocw3 <br /> Pass/Fail Threshold or Criteria: _ O•d07— k a•C)o z— to•c�a"t.-- <br /> Was sensor removed for testing? C Yes D No kNA ❑Yes DNo ,&NA D Yes 0 No ANA ❑Yes DNo DNA <br /> Was sensor properly replaced and D Yes DNo MA D Yes DNo 9NA D Yes DNo ;&A D Yes DNo DNA <br /> verified functional after testing? <br /> Comments—(Include in ormation on repairs made prior to testing,and recommended follow-upor ailed tests <br /> Li 171^ 3- `f v {n c-R-nce.E u {�av� <br /> 7H hrPalc J✓od a cF L`nie Loose a7L s hp rtc Ja/v e In X:eo <br /> If the entire depth of the UDC is not tested,specify how much was tested. If the answer to 1y of the questions indicated with an <br /> asterisk(+)is"NO"or"NA",the entire UDC must be tested (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.