My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2005-2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
153
>
2300 - Underground Storage Tank Program
>
PR0231389
>
COMPLIANCE INFO 2005-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
11/4/2018 4:32:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2011
RECORD_ID
PR0231389
PE
2361
FACILITY_ID
FA0003709
FACILITY_NAME
VALERO #3698
STREET_NUMBER
153
Direction
E
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23336607
CURRENT_STATUS
01
SITE_LOCATION
153 E ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\ELEVENTH\153\PR0231389\COMPLIANCE INFO 2005-2011.PDF
QuestysFileName
COMPLIANCE INFO 2005-2011
QuestysRecordDate
5/19/2017 6:00:47 PM
QuestysRecordID
3389699
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
372
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page k of 7- <br /> 8. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed By: ❑Sump Manufacturer 64ndustry Standard ❑Professional Engineer <br /> ❑Other(Specify) <br /> Test Method Used: ❑Pressure ❑Vacuum ZHydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: i pj co 0 Equipment Resolution: o . a o t <br /> Fill Sump# iq Fill Sump# r6 g- Fill Sump# Fill Sump# <br /> Sump Diameter: r, `6" 41? > <br /> Sump Depth: 2 28 <br /> Height from Tank Top to Top of <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest I t 2 3 it <br /> Electrical Penetration: <br /> Condition of sump prior to O k O K O y— <br /> testin : <br /> Portion of Sump Tested o a(( 0,(( <br /> Sump Material: ewr ks 5 csLr <br /> Wait time between applying <br /> pressure/vacuum/waterand S S Y),, t <br /> starting test: <br /> Test Start Time: ! / <br /> Initial Reading(Rj): -lot 6 3O <br /> Test End Time: p o 32 /03 Z <br /> Final Reading RF): 3 S•Slob 3 65 <br /> Test Duration: / -m i <br /> Change in Reading(R,-R,): —B-000 .{'0.Otz {O 066L <br /> Pass/Fail Threshold or Criteria: t 6 •o 6'L _F o . a 2- `t 0,o cL <br /> Test Result: c9-Pass ❑Fail 9 Pass ❑Fail iot Pass 0 Fail ❑,Pass ❑Fail <br /> Is there a sensor in the sump? Yes ❑No A Yes ❑No M Yes ❑No ❑Yes ❑No <br /> Does the sensor alarm when <br /> either product or water is )&Yes ❑No ❑NA AYes ❑No (INA RlYes ❑No [INA ❑Yes ❑No ❑NA <br /> detected? <br /> Was sensor removed for testing? dyes ❑No ❑NA Kyes ❑No ❑NA WYes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Was sensor properly replaced and <br /> verified functional after testis ? es ❑No ❑NA 9,Ycs 11No ElI NA Kes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up forfailed tests) <br />