My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
88 (STATE ROUTE 88)
>
18662
>
2300 - Underground Storage Tank Program
>
PR0505356
>
COMPLIANCE INFO_2010 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 9:21:32 AM
Creation date
11/4/2018 5:30:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2015
RECORD_ID
PR0505356
PE
2361
FACILITY_ID
FA0006733
FACILITY_NAME
GEORGES BP MINI MART
STREET_NUMBER
18662
Direction
N
STREET_NAME
STATE ROUTE 88
City
LOCKEFORD
Zip
95237
CURRENT_STATUS
01
SITE_LOCATION
18662 N HWY 88
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\HWY 88\18662\PR0505356\COMPLIANCE INFO 2010 - 2015.PDF
QuestysFileName
COMPLIANCE INFO 2010 - 2015
QuestysRecordDate
2/1/2018 7:40:19 PM
QuestysRecordID
3779163
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
198
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY 0 <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone: (209) 468-3420 Fax: (209) 468-3433 Web:www.sig©v.orglehd/unitiii.htmi <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Facility <br /> George's Mini Mart Address: 18662 N Hwy 88 Lockeford, CA Inspection May 15, 2012 <br /> VIOLATIONS <br /> # C1 C2 M I Code Section HSC=CA Health and Safety Code;CFR=Code of Federal Re ulations <br /> C1 =Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> Non-Pressurized Piping(continued) <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1, 1984) (M1) <br /> 703 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1, 1984) (Mt) <br /> Other Violations <br /> 999 Other: See attached"Continuation—Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II, or MINOR-Notice to Comply) <br /> On site to conduct a routine inspection and witness the annual monitoring system certification testing. <br /> 104. Financial responsibility documents have not been submitted to the EHD. The most recent copy on <br /> file is dated 5-1-11. Current financial responsibility documents are required to be submitted annually. <br /> During the inspection the employee provided a copy of the current financial responsibility documents <br /> dated 2-10-12. Continue to ensure that financial responsibility documents are required to be submitted <br /> annually. Corrected on site. <br /> 201. A facility alarm log and maintenance record for the 3-17-12 L4 diesel stp fuel alarm were not found <br /> on site. These records shall be kept on site for at least 3 years. Immediately locate and maintain the <br /> facility alarm log and maintenance record for the 3-17-12 L4 diesel stp fuel alarm on site and submit <br /> copies to the EHD by 6-15-12. Continue to ensure that alarms from the monitoring panel are <br /> documented by the facility and that maintenance records for those alarms are kept on site for three <br /> years. <br /> 204. The designated operator failed to document all the alarms from the attached alarm history on the <br /> April 2012 designated operator monthly inspection report and failed to check that they were responded <br /> to appropriately. The missing alarms include: the 3-17-12 L4 diesel stp fuel alarm. During the monthly <br /> inspection, the designated operator shall review the alarm history for the previous month, check that <br /> each alarm was documented and responded to appropriately, and attach a copy of the alarm history with <br /> documentation taken in response to any alarms to the monthly report. Ensure that designated operators <br /> performing monthly inspections at this facility are including all of the required information on the reports. <br /> 303. The diesel annular sensor was found not located at the bottom of the tank to detect a leak at the <br /> earliest opportunity. Technician had to lower the Veeder Root-420 bell sensor about one inch so that it <br /> could reach the bottom of the tank annular. Monitoring equipment shall be maintained to be able to <br /> detect a leak at the earliest possible opportunity. Continue to ensure that sensors are properly located to <br /> detect a leak at the earliest opportunity. Corrected on site. <br /> 303 & 305. The 87 turbine sump sensor is not working properly to ensure continuous monitoring of the <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Inspector: Received By, Title. <br /> EHD 23-02 Rev 49/01111 Page 3 UST INSPLCTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.