COMPLIANCE INFO 2002-2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
COMPLIANCE INFO 2002-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2021 3:50:10 PM
Creation date
11/5/2018 9:14:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2006
RECORD_ID
PR0518288
PE
2361
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\3250\PR0518288\COMPLIANCE INFO 2002-2006.PDF
QuestysFileName
COMPLIANCE INFO 2002-2006
QuestysRecordDate
7/5/2017 7:22:22 PM
QuestysRecordID
3481896
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
238
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page of I <br /> 7. UNDER-DISPENSER CONTAINMENT(UDC) TESTING <br /> Test Method Developed By: ©UDC Manufacturer Industry Standard G Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure E Vacuum Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used: Cts' if J (lGj f5 Equipment Resolution: <br /> UDC# Y UDC# [TDC# t LUC#x tz <br /> UDC Manufacturer: r v t co t�_ <br /> UDC Material: �L Q'3�I_ % <br /> UDC Depth: �t F <br /> Height from UDC Bottom to Top y <br /> of Highest Piping Penetration: d 1 <br /> Height from UDC Bottom to k , <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to <br /> testing: <br /> Portion of UDC Tested' V2 h i h4 11 1 E C l <br /> Does turbine shut down when ❑Yes 11 No ��rrNA <br /> UDC sensor detects liquid(both � D Yes D No �XA D Yes ❑No �NA Q Yes ❑No �NA <br /> product and water)?* <br /> Turbine shutdown response time <br /> Is system programmed for fail- ❑Yes ❑No OLNA D Yes Q No YNA ❑Yes Ll No �NA ❑Yes ❑No �NA <br /> safe shutdown'?' <br /> Was fail-safe verified to be ❑Yes ❑No NA ❑Yes D No )�NA D Yes D No �NA D Yes ❑No Y -- <br /> operational?` <br /> Wait time between applying <br /> pressure/vacuum/water and a ) <br /> starting test <br /> Test Start Time: / ) 2:Z <br /> Initial Reading 12-. 029 - 7 <br /> Test End Time: 2-7 11 s l Z <br /> Final Reading(RF): 11. 0alz q, f Z 7 / Z,7 ck 75- <br /> Test Duration. i Jj I I +f <br /> Chane in Reading &): G C D 1 q , L'D U p .4p-cc)00 0&)?- <br /> Pass/Fail Threshold or Criteria: ,O -00 0,002, 0,Lo <br /> Test Result: X Pass. :0 Fail i1�Pass ''0 Fail ;-.,� Pass , 0 Fail X Pass : ❑Fail <br /> Was sensor removed for testing? ;K'Yes ❑No D NA �1'e8 <br /> ❑No ❑NA 7&es ❑No ❑NA [ Yes ❑No ❑NA <br /> Was sensor properly replaced and .Yes C1 No C NAL1No D NA ` •Yes ❑No ❑NA Yes [I No ❑NA <br /> verified functional after testing? Ireyes <br /> Comments—(include information on repairs made prior to testing and recommended follow-u for failed tests) <br /> Costco #658 <br /> 3250 Grantline & Hwy 205 <br /> Tracy, CA 95377 <br /> If the entire depth of the UDC is not tested,specify how much was tested. If the answer to Agy of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRC13 LG-160) <br />