My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2002-2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
COMPLIANCE INFO 2002-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2021 3:50:10 PM
Creation date
11/5/2018 9:14:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2006
RECORD_ID
PR0518288
PE
2361
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\3250\PR0518288\COMPLIANCE INFO 2002-2006.PDF
QuestysFileName
COMPLIANCE INFO 2002-2006
QuestysRecordDate
7/5/2017 7:22:22 PM
QuestysRecordID
3481896
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
238
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page of <br /> 8. FILE RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed By: C Sump Manufacturer Industry Standard C Professional Engineer <br /> []Other(Specify) <br /> Test Method Used: ❑Pressure D VacuumHydrostatic <br /> ❑Other(SpeG�) / <br /> Test Equipment Used:o a#4iL e% oo(; t,;,`uo • Equipment Resolution: <br /> Fill Sump# l 1 Sump# ill Sum SQA Fill Sump SL.At� <br /> Sump Diameter. q K r+ of rt It <br /> Sump Depth: ,r S 1 <br /> Height from Tank Top to Top of ,� rr r r <br /> Highest Pi in Penetration ZZ tZI <br /> Height from Tank Top to Lowest q a t <br /> Electrical Penetration: Z6 U 2-5 � �S <br /> Condition of sump prior to <br /> testing: t c Y? t t 1 t <br /> Portion of Sump TestedI•-h y__ it <br /> Sump Material: a ra <br /> Wait time between applying <br /> pressure/vacuum/water and Gl Ji G1 <br /> startLng test: <br /> Test Start Time: 11-11 ,45 a <br /> Initial Reading ): 1q. YLO5 I l jv S t l <br /> Test End Time: 1'Z t 4 S B ! L `•5 -'i <br /> Final Reading 1 G �D Zt,Ll r�= 7 S rr <br /> Test Duration: j , ., t-Z <br /> Change in Reading(RF-RI)- 11 0,017, 0 + C?cx�(!Do <br /> Pass/Fail Threshold or Criteria: IOUVI,,1, C Z ,0,02, 010c:3— <br /> Test Result:. Pass C Fail ass`''-C]Fail X Pass ❑.Fail Pass::-- 0 Fail <br /> Is there a sensor in the sump? Yes ❑No Yes ❑No Yes ❑No Yes C No <br /> Does the sensor alarm when 11 Yes ❑Na NA <br /> either product or water is 0 Yes ❑No rNA ❑Yes C No `�NA ❑Yes ❑No ANA <br /> detected? <br /> Was sensor removed for testing? L Yes ❑No B NA FYes ❑No QNA es C No C9 NA Yes ❑No [INA <br /> i t <br /> Was sensor properly replaced and Yes ❑No 17 NA ❑No 11 NA :Yes El No NA es ONO ❑NA <br /> verified functional after testing? PYes <br /> COmments—(include information on repairs made prior to testing, and recomrnendedfollow-up or failed tests) <br /> Costco#658 <br /> 3250 Grantline & Hwy 205 <br /> Tracy, CA 95377 <br />
The URL can be used to link to this page
Your browser does not support the video tag.