My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2002-2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
COMPLIANCE INFO 2002-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2021 3:50:10 PM
Creation date
11/5/2018 9:14:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2006
RECORD_ID
PR0518288
PE
2361
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\3250\PR0518288\COMPLIANCE INFO 2002-2006.PDF
QuestysFileName
COMPLIANCE INFO 2002-2006
QuestysRecordDate
7/5/2017 7:22:22 PM
QuestysRecordID
3481896
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
238
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page!of 7 D <br /> S. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps C1 <br /> Fill Riser Containment Sumps are Present,but were Not Tested 11 <br /> Test Method Developed By: 0 Sump Manufacturer ;KIndustry Standard [I Professional Engineer <br /> [I Other(Specify) <br /> Test Method Used: 0 Pressure El Vacuum Hydrostatic <br /> [I Other(Spe4ify) <br /> ffi ed Equipment Resolution-. <br /> Test Equipment Used: CL <br /> M <br /> M R�717KWN'X <br /> FW Sump <br /> Fill Sump Fill Sump# Fill Sump# <br /> Sura p Diameter: <br /> Sump Depth: <br /> Height from Tank Top to Top of <br /> Highest P�p�Penetration 2 <br /> Height from Tank Top to Lowest Ir <br /> Electrical Penetration: 3Z- 3z <br /> Condition of sump prior to <br /> testing: c)0'P <br /> Portion of Sump Tested It <br /> Sump Material: F-, E*C i-4s <br /> Wait time between applying <br /> pressure/vacuum/water and <br /> -A—ard—ng test: <br /> Test Start Time: <br /> Initial Reading(Rj): <br /> Test End Time: ef 1:2-2 <br /> Final Reading(RF): 1-2— 3)1 T <br /> Test Duration: zIV__ <br /> Change in Reading(RF-RI): 0(21 iz 1:9- rool'�� <br /> Pass/Fail Threshold or Criteria: 100.il- ().OcZ CC 0•c <br /> am <br /> Result: IXPass LI Fail Pass [I Fail 0 Pass C Fail 11 Pass E Fail <br /> Is there a sensor in the sump? )I Yes 11 No -'ff-Yes 11 No $Yes [I No ::AYes :1 No <br /> Does the sensor alarm when <br /> either product or water is 11 Yes 0 No )C NA 11 Yes 0 No INA 71 Yes F1 No �NA E Yes LI No XNA <br /> I detected? <br /> Was sensor removed for testing? —VYes CNo [INA Fes []No _ es [ <br /> LINA -]No C9 NA ryes []No �INA <br /> Was sensor properly replaced and ,Yes CNo EINA es 0 No [I NA <br /> verified functional after testing? I I lyes <br /> L No CI NA )g4"s ENo CNA <br /> -Comments—(include information on repairs made prior to tesy & and recommendedfollow-upforfailed tests) <br /> Costco #E358 <br /> 3250 Grantline & Hwy 205 <br /> Tracy, CA 95377 <br />
The URL can be used to link to this page
Your browser does not support the video tag.