Laserfiche WebLink
Page ? of <br /> ;WRCB.January 2002 <br /> 7. UNDER-DISPENSER CONTAINMENT C TESTING <br /> Test Method Developed By: ❑UDC Manufacturer X Industry Standard ❑Professional Engineer <br /> ❑Other(Specify) <br /> Test Method Used: ❑Pressure <br /> ❑Vacuum X Hydrostatic <br /> ❑Other(Specify) <br /> Equipment Resolution:ui <br /> Test Equipment Used: See attached testing procedures. E q p <br /> Y _ <br /> 101 _. unc# _r�� Iibc# LTDC# UDe# /I -ice_ <br /> UDC Manufacturer: C N ori L'"� � R S"�-7 L <br /> UDC Material: 7 C_ <br /> fr <br /> UDC De the <br /> Height from UDC Bottom to Top <br /> of Hi est Piping Penetration: <br /> Height from UDC Bottom to <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to rf r <br /> testing: Above highest <br /> Above highest Above highest Above highest 9 <br /> Portion of UDC Tested netration nanetration nenetration penetration <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both [3 Yes L3 No X NA ❑Yes a No X NA yes ❑No X NA C1 Yes ❑No X NA <br /> product and water)?* <br /> Turbine shutdown response time <br /> Is system programmed for fail- X yes ❑No CNA X Yes []No SNA X Yes ❑No [INAX Yes ❑No ENA <br /> safe shutdown?* <br /> Was fail-safe verified to be ❑Yes X No LINA ❑Yes X No i-NA ❑Yes X No ❑NA ❑Yes X No ENA <br /> o erationalf <br /> Wait time between applying <br /> 30 minutes 30 minutes <br /> pressure/vacuum/water and 30 minutes 30 urinates <br /> starting test <br /> Test Start Time: -� 15 / <br /> Initial Reading(RO: _ C' <br /> Test End Time: <br /> Final Reading(Rr): - { <br /> Test Duration: J r <br /> Change in Reading(F-F-RO: 0- 00 �) C3. CSG►c> CMZ <br /> Pass/Fail Threshold or Criteria: 0.002 0.002 4.002 <br /> Test Result: Pass t3 Fail J�'Pass ❑Fail ❑ Pass ail ❑ Pass ail <br /> Was sensor removed for testing? X Yes ❑No [)NA X Yes ❑No LINA X Yes ❑No ❑NA X Yes ❑No ❑NA <br /> Was sensor properly replaced and X Yes 11No ❑NA X Yes ❑No DNA X Yes ❑No [INAX Yes 11No DNA <br /> verified functional after testi n ? <br /> Comments-- (include in ormation on repairs made prior to testing, and recomme72ded ollo)r-up or failed tests <br /> �sfL'Vs'tw //– �� /r�Yr E L23L 0 . ` v�C"Lv7v'e <br /> SB 989 3-Year Compliance Testing <br /> WO#060310-045 <br /> CQSTCO#200737 — <br /> 3250 W Grant Lime 1 Hwy 205 — <br /> Tracy,CA 95304 <br /> i If the entire depth of the UDC is not tested,specify how much was tested. If the answer to Any of the questions indicated with an <br /> asterisk(*)is"NO" or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />