COMPLIANCE INFO 2002-2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
COMPLIANCE INFO 2002-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2021 3:50:10 PM
Creation date
11/5/2018 9:14:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2006
RECORD_ID
PR0518288
PE
2361
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\3250\PR0518288\COMPLIANCE INFO 2002-2006.PDF
QuestysFileName
COMPLIANCE INFO 2002-2006
QuestysRecordDate
7/5/2017 7:22:22 PM
QuestysRecordID
3481896
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
238
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCg,_January2002 \ Pzge_Iof <br /> S. FII.L RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sums ❑ <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed By: ❑Sump Manufacturer X Industry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure ❑Vacuum X Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: See attached testing procedures Equipment Resolution: <br /> Fill Sump# V,7r/ Fill Sump# qrl Fill Sump# 7 rz Fill Sump# 7T <br /> Sum Diameter: �e <br /> Sump Depth: " Z <br /> Height from Tank Top to Top of 2- 4 <br /> Highest Piping Penetration: 2,.Z 4; r <br /> Height from Tank Top to Lowest e C r <br /> Electrical Penetration: Z Ae <br /> Condition of sump prior to $ <br /> testing: <br /> Portion of Sump Tested Above highest Above highest Above highest Above highest <br /> enetration penetration penetration penetration <br /> Sump Material&Manufacturer: - ,+r <br /> Wait time between applying <br /> pressure/vacuum/water and 30 minutes 30 minutes 30 minutes 30 minutes <br /> starting test: <br /> Test Start Time: U <br /> Initial Reading(RD: 2 S'0j, 2 5- ! 1'967P J41 <br /> Test End Time: / : O : O / '- S <br /> FinalReadin (RF): /A 2— <br /> Test <br /> Test Duration: <br /> Chane in Reading(Rf- : ea , ae2 a Z <br /> Pass/Fail Threshold or Criteria: 0.002 0.002 0.002 0.002 <br /> Test Result: `Pass OF ill Pass ❑Fail XPass ❑Fail X Pass ❑Fail <br /> Is there a sensor in the sump? X Yes ❑No X Yes ❑No X Yes ❑No X Yes ❑No <br /> Does the sensor alarm when <br /> either product or water is X Yes ❑No @]A X Yes ❑No ENA X Yes ❑No ❑NA X Yes O No ENA <br /> detected? <br /> Was sensor removed for testing? X Yes ❑No DNA X Yes ❑No DNA X Yes ❑No DNA X Yes D No DNA <br /> Was sensor properly replaced and X_Yes ❑No DNA X Yes D No DNA X_Yes 0 No DNA X Yes ❑No DNA <br /> verified functional after testin ? <br /> Comments—(include information on repairs made prior to lesling, and recommended follow-up for jailed tests) <br /> SB 989 3-Year Compliance Testing <br /> WO#060310-045 <br /> COSTCO#200737 <br /> 3250 W Grant Line/Hwy 205 <br /> Tracy,CA 95304 <br />