Laserfiche WebLink
1 Ade-ground Storage Tank Response ' i— Page 2 of 2 <br /> r.i <br /> VI. LEAK INTERCEPTION AND DETECTION SYSTEM <br /> P�,su,for�mwi.n required only for motor vehicle fuel UST systems constructed per the Alternate Construction Requirements of 23 CCR$2633,and only if the Leak <br /> Interception and Detection System (LIDS) does not meet the volumetric requirements of 23 CCR §2631(d)(1) through (5) 0 e., when accounting for rainfall and <br /> backfill material,the secondary containment volume is less than 100%of primary tank volume for a single LIST;or in the case of multiple USTs in shared secondary <br /> containment,150"/0 of the largest primary tank volume or 10%of aggregate primary tank volume,whichever is greater). <br /> ATTACH AN ADDITIONAL PAGE TO THIS PLAN CONTAiNING THE FOLLOWING INFORMATION: <br /> D The volume of the LIDS in relation to the volume of the primary container-, <br /> > The amount of time the LiDS shall provide containment related to the time between detection of an unauthorized release and cleanup of the leaked suhstancc; <br /> > The depth from the bottom of the LiDS to the highest anticipated level of groundwater; <br /> > The nature of the unsaturated soils under the LiDS and their ability to absorb contaminants or In allow movement of contaminants; <br /> > The methods and scheduling fnr removal of all hazardous snhstances which may have been discharged from primary containment and arc localed in the <br /> unsaturated soils between the prima containment and groundwater,including the LIDS sump. <br /> VII. REPORTING AND RECORD KEEPING <br /> We will report/record any overfill,spill,ar unauthorized release from a UST systern as indicated in this plan. <br /> Recordable Releases: Any unauthorized release from primary containment which the UST operator is able to clean up within eight (8)(tours after the release was <br /> detected or should reasonably have been detected,and which does not escape from secondary containment,does not increase the hazard of fire or explosion,and does <br /> not cause any deterioration of secondary containment,most be recorded in the facility's monitoring records. Monitoring records must include: <br /> > The UST operator's name and telephone number; <br /> > A list of the types,quantities,and concentrations of hazardous substances released, <br /> > A description of the actions taken to control and clean up the release; <br /> > The method and location of disposal of the released hazardous substances,and whether a hazardous waste manifest was or will be used, <br /> > A description of actions taken to repair the UST and to prevent future releases; <br /> > A description of the method used to reactivate interstitial monitoring after replacement or repair of primary containment- <br /> Reportable Releases: Any overfill, spill,or unauthorized release which escapes from secondary containment(or primary containment if no secondary containment <br /> exists),increases the hazard of fire or explosion,or causes any deterioration of secondary containment,is a reportable release. Reportable releases are also recordable. <br /> Within 24 hours atter a reportable release has been detected,or should have been detected, the will notify the local agency administering the LIST program of the <br /> release,investigate the release,and take immediate measures to stop the release. if necessary,or if required by the local agency,remaining stored product/waste will <br /> be removed from the UST to prevent further releases or facilitate corrective action, Iran emergency exists,we will notify the State Office of Emergency Services. <br /> Within five(5)working days of a reportable release,we will submit to the local agency a full written report containing all of the following information to the extent <br /> that the information is known at the time of filing the report: <br /> D The UST owner's or operator's name and telephone number; <br /> > A list of the types,quantities,and concentrations of hazardous materials released; <br /> > The approximate date of the release; <br /> > The date on which the release was discovered; <br /> > The date on which the release was stopped; <br /> > A description of actions taken to control and/or stop the release; <br /> > A description of corrective and remedial actions,including investigations which were undertaken and will be conducted to determine the nature and extent of <br /> soil,ground water or surface water contamination due to the release; <br /> > The methods)ofeleanup irrtplemented to date,proposed cleanup actions,and a schedule for implementing the proposed actions; <br /> > The method(s)and location(s)of disposal of released hazardous materials and any contaminated soils,groundwater,or surface water. <br /> > Copies of any hazardous waste manifests used for off-site transport of hazardous wastes associated with clean-up activity; <br /> > A description of proposed methods for any repair or replacement of UST system primarylsecondary containment systems; <br /> > A description of additional actions taken to prevent future releases. <br /> We will follow the reporting procedures described above if any of the following conditions occur: <br /> > A recordable unauthorized release can not be cleaned up or is still under investigation within eight(g)hours of detection; <br /> > Released hazardous substances are discovered at the UST site Or in the surtounding area; <br /> > Unusual operating conditions are observed, including erratic behavior of product dispensing equipment,sudden loss of product,or(fie unexplained presence of <br /> water in the tank,unless system equipment is found to be defective and is immediately repaired or replaced,and no leak has occurred; <br /> > Monitoring results from UST system monitoring equiprnent/methocls indicate that a release may have occurred,unless the monitoring equipment is found to be <br /> defective and is immediately repaired,recalibrated,or replaced,and additional monitoring does not confirm the initial results. <br /> Record Retention: Monitoring records and written reports of unauthorized releases must he maintained on-site(or off-site at a readily available location,ifapproved <br /> by the local agency)for at least 3 years. I lazardous waste shipping/disposal records(e.g.,manifests)must he maintained for at least 3 years from the date of shipment. <br /> XVIII. OWNERIOPERATOR SIGNATURE <br /> CERTIFICATION:i certify that the information provided herein is true and accurate to the best of my knowledge. <br /> OWN 'OPERA" SiG A;�URF DATE M <br /> OUNF 0 FR A-TY IR NA MF fnri R71 OWNFRIOPFiRATOR TITLE. R7. <br /> i ( ✓ti/� ski Z'4 -Jr -5— / J1;' 0 f2 '50 <br /> (Agenci,Use 01119 This has been reviewed and: Approved ❑Approved With Conditions ❑ 1)isappr ed <br /> Local Agency Signator -- ----- Date: a v <br /> ETN-022B-313 Www.unidoes-or, <br /> 1. Rev. 10114103 <br />