®1 <br />PANEL SCHEDULE I PANEL SCHEDULE NOTES I GENERAL NOTES <br />VOLTAGE 120,/240LOCATION LUBE BAY <br />PHASE 1 WIRE 3 0 PANEL A (EXISTING) MOUNTING SURFACE <br />BUS AMPS 200A MAIN AMPS 175A DWG. NO. E2 <br />DESCRIPTION <br />w <br />PANEL <br />MAIN AMPS <br />VOLT AMPS <br />BRKR <br />CKT <br />N0. <br />BUS <br />CONN. <br />CKT <br />NO. <br />BRKR <br />VOLT AMPS <br />J <br />CKT <br />N0. <br />DESCRIPTION <br />A <br />B <br />AMP <br />P <br />P <br />AMP <br />A <br />B <br />EXISTING CKT <br />P <br />P <br />AMP <br />A <br />30 <br />1 <br />1 <br />1000 <br />CONDENSER <br />20 <br />3 <br />1 <br />20 <br />CPU <br />CENTRAL PROCESSING UNIT <br />2 <br />2 <br />EXISTING CKT <br />1000 <br />EMR <br />EMERGENCY <br />4 <br />1 <br />20 <br />EXHAUST FAN <br />ES <br />ENERGY SAVING <br />FUEL DISP. #5-8 (PWR) <br />EXISTING CKT <br />EXISTING CKT <br />EXISTING <br />20 <br />1 <br />3 <br />5 <br />20 <br />1 <br />2 <br />G, GND <br />1000 <br />7 <br />1 <br />20 <br />6 <br />EXISTING CKT <br />EXISTING CKT <br />1000 <br />20 <br />1 <br />5 <br />FUEL DISP. LTS <br />8 <br />1 <br />20 <br />120 <br />1 <br />7 <br />9 <br />8 <br />EXISTING CKT <br />EXISTING CKT <br />1000 <br />20 <br />1 <br />6 <br />11 <br />1 <br />20 <br />SPACE <br />EXISTING CKT <br />EXISTING CKT <br />11 <br />13 <br />12 <br />20 <br />1 <br />9 <br />- <br />12 <br />1 <br />20 <br />14 <br />EXISTING CKT <br />EXISTING CKT <br />SPACE <br />20 <br />1 <br />10 <br />EXISTING CKT <br />20 <br />1 <br />13 <br />152 <br />SPACE <br />EXTERIOR LTS(CKT 1-12) <br />EXISTING CKT <br />TOTALS <br />2600 <br />20 <br />1 <br />14 <br />16 <br />2000 <br />900 <br />VOLT AMPS: BUS A <br />BUS B <br />TOTAL <br />4600 <br />2000 <br />6600 <br />SAME AS CKT 14 <br />DEMAND FACTOR <br />DEMAND FACTOR <br />_x <br />1.0 <br />19 <br />2 <br />0 <br />6.6 <br />6.6 <br />27,0 <br />EXISTING CKT <br />EXISTING CKT <br />17 <br />20 <br />20 <br />EXISTING CKT <br />EXISTING CKT <br />18 <br />- <br />EXISTING CKT <br />20 <br />1 <br />21 <br />23 <br />EXISTING CKT <br />EXISTING CKT <br />20 <br />1 <br />22 <br />24 <br />EXISTING CKT <br />27 <br />- <br />- <br />SPACE <br />- <br />FUEL SUB PNL "B" <br />4600 <br />70 <br />25 <br />SAME AS CKT 25 <br />2000 <br />2 <br />26 <br />28 <br />- <br />- <br />SPACE <br />SPACE <br />- <br />- <br />29 <br />31 <br />- <br />- <br />SPACE <br />32 <br />2 <br />AIR COMPRESSOR <br />EXISTING CKT <br />20 <br />1 <br />30 <br />EXISTING CKT <br />15 <br />1 <br />33 <br />35Z <br />20 <br />SAME AS CKT 32 <br />EXISTING CKT <br />20 <br />1 <br />34 <br />36 <br />RONAN <br />TOTALS <br />- <br />- <br />- <br />- <br />VOLT AMPS: BUS A - DEMAND FACTOR —x LCL KVA —x 1.25= - <br />BUS B - DEMAND FACTOR — x NON LCL KVA _ - <br />TOTAL - TOTAL KVA - <br />10 AMPS - <br />VOLTAGE 120/ 42_Q <br />PHASE 1WIRE 3 <br />BUS AMPS 100A <br />AMPS <br />� <br />PANEL <br />MAIN AMPS <br />B (NEW) ++ <br />M.L.O. <br />ABOVE FINISHED GRADE <br />AWG <br />LOCATION LUBE BAY <br />MOUNTING SURFACE <br />DWG. NO. F2 <br />DESCRIPTION <br />W <br />VOLT AMPS <br />A B <br />BRKR <br />CKT <br />N0. <br />BUS <br />CONN. <br />CKT <br />NO. <br />BRKR <br />VOLT <br />AMPS <br />J <br />CONDUIT <br />DESCRIPTION <br />CABINET <br />AMP <br />P <br />P <br />AMP <br />A <br />B <br />FUEL DISP. #1-4 (PWR) <br />CONDUIT ONLY <br />1000 <br />CONDENSER <br />20 <br />1 <br />1 <br />COPPER <br />CPU <br />CENTRAL PROCESSING UNIT <br />2 <br />2 <br />DWG <br />1000 <br />EMR <br />EMERGENCY <br />EMT <br />TURBINE (R.U.) <br />EF <br />EXHAUST FAN <br />ES <br />ENERGY SAVING <br />FUEL DISP. #5-8 (PWR) <br />EVAPORATIVE COOLER <br />(E), EX, <br />EXISTING <br />20 <br />1 <br />3 <br />5 <br />4 <br />20 <br />G, GND <br />1000 <br />SAME AS CKT <br />2 <br />6 <br />2 <br />1000 <br />TURBINE (S.U.) <br />FUEL DISP. LTS <br />__1000 <br />600 <br />120 <br />1 <br />7 <br />9 <br />8 <br />20 <br />1000 <br />SAME AS CKT <br />6 <br />10 <br />SPACE <br />11 <br />13 <br />12 <br />SPACE <br />SPACE <br />14 <br />SPACE <br />SPACE <br />15 <br />16 <br />SPACE <br />TOTALS <br />2600 <br />2000 <br />2000 <br />VOLT AMPS: BUS A <br />BUS B <br />TOTAL <br />4600 <br />2000 <br />6600 <br />DEMAND FACTOR <br />DEMAND FACTOR <br />_x <br />1.0 <br />LCL <br />x NON <br />KVA —x 1.25= <br />LCL KVA 6_6 = <br />T01FAL KVA <br />10 AMPS <br />0 <br />6.6 <br />6.6 <br />27,0 <br />I SINGLE LINE DIAGRAM <br />hQTE: <br />(EMAXIMUM DEMAND LOAD DURING LAST <br />(E X.) 200A MAIN SERVICE <br />REMAIN (120V SERVICE <br />10,3W) 12 MONTHS = 3,800 KWH, DEC„1994, <br />/ PER PG&E SERVICE PLANNER: <br />— — — — — --I— — — — — — -1 CHARLENE CAR;NAHAN 0 (209) 942-1461 <br />I � <br />m)( EXISTING 200A <br />/ METER PG&E <br />((EX.)175A — — 1 I #A43234 <br />C/O 2 -POLE <br />I I I I 1 I <br />I PANEL i l <br />EXISTING MAIN� I <br />PANEL ' <br />REMAIN A° TO L— — J <br />I I I <br />L --- ---I--- I J <br />o F <br />z I <br />+ <br />o L_ <br />M S d <br />I o <br />o — EX.) TC + FEEDERS TO <br />o a OWER CO. P.O.C. TO <br />n REMAIN <br />NEW v <br />NEW 100A SUB- <br />16-CKT PANEL <br />120/24OV, 10, If <br />3W PANEL <br />(FUEL) <br />- — — - EXISTING TO <br />REMAIN <br />INDICATES NEW <br />EXISTING MAIN PANEL "A' TO REMAIN FUNCTIONAL. ALL CIRCUITS TO <br />REMAIN FUNCTIONAL AS IS UNLESS OTHERWISE NOTED, CONTRACTOR TO <br />VERIFY ALL CIRCUITS AND REMOVE UNUSED CIRCUIT BREAKERS AND <br />THE ASSOCIATING WIRES. PROVIDE PROPER CIRCUIT INDENTIFICAT10N TAG <br />ON PANEL DOOR. <br />MODIFY EXISTING CIRCUIT. PROVIDE AND INSTALL NEW CIRCUIT BREAKER <br />AS SHOWN. CONTRACTOR TO VERIFY REQUIREMENTS. <br />PROVIDE AND INSTALL NEW FUEL SUB -PANEL "B" ADJACENT TO EXISTING <br />MAIN PANEL "A SEE DWG. "E-2" FOR LOCATION. CONTRACTOR TO <br />FURNISH ALL NEW CIRCUIT BREAKERS AS SHOWN. <br />®PROVIDE AND INSTALL NEW SWITCH NEUTRAL COMMON TRIP CIRCUIT <br />BREAKERS FOR FUEL DISPENSER CIRCUITS PER N.E.C. 514-5, 1993. <br />ABBREVIATIONS <br />A <br />AMPS <br />AFF <br />ABOVE FINISHED FLOOR <br />AFG <br />ABOVE FINISHED GRADE <br />AWG <br />AMERICAN WIRE GAGE <br />AUX <br />AUXILLARY <br />BAT <br />BATTERY <br />BIRD <br />BOARD <br />BRKR <br />BREAKER <br />BLDG <br />BUILDING <br />C <br />CONDUIT <br />CAB <br />CABINET <br />CB <br />CIRCUIT BREAKER <br />CLG <br />CEILING <br />CKT <br />CIRCUIT <br />CO <br />CONDUIT ONLY <br />COND <br />CONDENSER <br />CP <br />CONTROL PANEL <br />CU <br />COPPER <br />CPU <br />CENTRAL PROCESSING UNIT <br />DS <br />DISCONNECT SWITCH <br />DWG <br />DRAWING <br />EMR <br />EMERGENCY <br />EMT <br />ELECTRICAL METALIC TUBING <br />EF <br />EXHAUST FAN <br />ES <br />ENERGY SAVING <br />EVAP CLR <br />EVAPORATIVE COOLER <br />(E), EX, <br />EXISTING <br />EXIST. <br />GFI <br />GROUND FAULT CIRCUIT <br />INTERRUPTER <br />G, GND <br />GROUND <br />HPS HIGH PRESSURE SODIUM <br />HTR <br />IG <br />ISOLATED GROUND <br />KVA <br />KILOVOLTAMPERS <br />KW <br />KILOWATT <br />LCL <br />LONG CONTINUOUS LOAD <br />LTG <br />LIGHTING <br />MDP <br />MAIN DISTRIBUTION PANEL <br />MECH <br />MECHANICAL <br />MH <br />METAL HALIDE <br />MTD <br />MOUNTED <br />NEC <br />NATIONAL ELECTRICAL CODE <br />NL <br />NIGHT LIGHT <br />NTS <br />NOT TO SCALE <br />P <br />POLE <br />RECPT, <br />RECEPTACLE <br />ST <br />STAGGERED STRIP LUMINAIRE <br />T <br />TRANSFORMER <br />TEL. <br />TELEPHONE <br />TYP <br />TYPICAL <br />UL <br />UNDERWRITERS LABORATORY <br />LON <br />UNLESS OTHERWISE NOTED <br />XFMR <br />TRANSFORMER <br />V <br />VOLTS <br />WH <br />WATER HEATER <br />WP <br />WEATHERPROOF <br />WTR <br />WATER <br />11. EXACT ROUTING OF ALL CONDUITS WITHIN THE EXISTING BUILDING <br />SHALL BE DETERMINED BY THE CONTRACTOR. ANY COST REQUIRED <br />TO ROUTE CONDUITS DIFFERENTLY THAN IS SHOWN OF THESE <br />DRAWINGS SHALL BE INCURRED BY THE E.C.. <br />12. ALL MATERIALS AND EQUIPMENT SHALL BE DELIVERED TO THE SITE NEW, <br />IN THEIR ORIGINAL UNBROKEN PACKAGES BEARING APPROVAL BY U.L., <br />NEMA, NBFU OR OTHER APPROPRIATE AGENCY, AND INSTALLED PER <br />THEIR GUIDELINES. <br />13. CONTRACTOR SHALL PROVIDE A COMPLETE AND FUNCTIONING ELECTRICAL <br />SYSTEM MEETING THE INTENT OF THESE PLANS AND SPECIFICATIONS. <br />ALL SYSTEMS SHALL BE IN FOR INSPECTION. <br />14. CONTRACTOR SHALL MAINTAIN GROUND CONTINUITY TO EVERY OUTLET <br />PER N.E.C., TABLE 250-95, 1993. <br />15. ALL WIRES AND CABLES SHALL BE COPPER, 600 VOLT, #12 AWG MINIMUM. <br />EXCEPT CONTROL WIRING WHICH SHALL BE #18 THWN. CONDUCTORS <br />#10 AWG AND SMALLER SHALL BE SOLID. CONDUCTOR #8 AWG AND <br />LARGER SHALL BE STRANDED. TYPE OF INSULATION AS NOTED ON <br />DRAWINGS AND AS FOLLOWS: <br />- THHN/THWN INSULATION FOR #4 AWG AND SMALLER. <br />THW OR THHN/THWN INSULA # <br />2 AWG AND LARGER. <br />TTION FOR <br />- THW USED FOR ALL PANEL FEEDERS AND SERVICE CONDUCTORS. <br />- THHN INSULATION TYPE SHALL BE USED WHERE CONDUCTORS <br />ARE INSTALLED IN CONDUITS EXPOSED TO THE WEATHER, <br />16. ALL ELECTRICAL EQUIPMENT SHALL BE ANCHORED FOR SEISMIC LOADING <br />RESIST A HORIZONTAL FORCE ACTION IN ANY DIRECTION USING THE <br />FOLLOWING CRITERIA: <br />FIXED EQUIPMENT ON GRADE 33% OF OPERATING WEIGHT <br />FIXED EQUIPMENT ON STRUCTURE 50% OF OPERATING WEIGHT <br />FOR FLEXIBLY MOUNTED EQUIPMENT USE 2 TIMES THE ABOVE VALUES. <br />SIMULTANEOUS VERTICAL FORCE USE 1/3 TIMES HORIZONTAL FORCE. <br />THIS CRITERIA APPLIES TO EQUIPMENT ON THE FLOOR, WALL, OR ROOF <br />WITH AN OPERATING WEIGHT OF LESS THAN 1,000 LB.. <br />17, CONTRACTOR IS RESPONSIBLE FOR ALL CORING, CUTTING, PATCHING <br />AND REFINISHING OF WALLS AND SURFACES WHENEVER IT IS NECESSARY <br />PENETRATION. ALL OPENINGS MADE SHALL BE SEALED TO MEET THE <br />FIRE RATING AND STRUCTURAL INTRGRITY OF THE PARTICULAR WALL, <br />FLOOR, OR CEILING. <br />18. ALL ELECTRICAL FIXTURE AND EQUIPMENT SHALL BE GROUNDED. ALL <br />CONVENIENCE RECEPTACLES SHALL BE GROUNDING TYPE. <br />19. ELECTRICAL CONTRACTOR SHALL FURNISH TEMPORARY CONSTRUCTION <br />POWER WHERE REQUIRED. <br />LEGEND <br />1. SHOULD A CONFLICT OCCUR BETWEEN OR WITHIN THE SPECIFICATIONS <br />AND/OR DRAWINGS, CODES, STANDARDS, REQUIREMENTS, MANUFACTURER'S <br />INSTRUCTIONS OR RECOMMENDATIONS, THE MORE STRINGENT AND/OR <br />RESTRICTIVE CONDITION SHALL HAVE PRECEDENCE, AS DETERMINED BY <br />THE CONTRACTING OFFICER. <br />2. THE DRAWINGS REPRESENT THE FINISHED PROJECT UNLESS OTHERWISE <br />NOTED, THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE <br />CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND HE SHALL <br />BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, <br />TECHNIQUES, SEQUENCES, <br />3. ALL DIMENSIONS, EXISTING JOB SITE CONDITIONS, AND SERVICE REQUIRE- <br />MENTS SHALL BE VERIFIED BY THE CONTRACTOR BEFORE THE START OF <br />CONSTRUCTION AND/OR FABRICATION OF MATERIALS. IF DISCREPANCIES <br />ARE ENCOUNTERED, THE ENGINEER SHALL BE NOTIFIED FOR CLARIFICATION. <br />4. CONTRACTOR SHALL COORDINATE WORK BETWEEN ALL TRADES AND <br />WORKMEN TO CLOSE, PATCH AND REPAIR ALL HOLES WHERE ITEMS ARE <br />REMOVED AND PROVIDED OPENINGS AS NECESSARY FOR NEW WORK. <br />5. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH NATIONAL <br />ELECTRICAL CODE (93 EDITION), AND ALL APPLICABLE STATE, COUNTY, <br />AND LOCAL CODES APPLYING TO THE PROPOSED CONSTRUCTION. IN THE <br />EVENT OF CONFLICT BETWEEN THE ABOVE AND THESE PLANS AND <br />SPECIFICATIONS, THE MOST RESTRICTIVE SHALL GOVERN. <br />6. CONTRACTOR SHALL VERIFY ALL INFORMATION PERTAINING TO SERVICE <br />BY THE UTILITIES AND SHALL INCLUDE THE COST OF ALL WORK BY OR <br />FOR THEM IN HIS BID. <br />7. ELECTRICAL CONTRACTOR SHALL PROVIDE A COMPLETE AND OPERATIONAL <br />ELECTRICAL SYSTEM, EXCEPT THAT THE PROVISIONS FOR OWNER -SUPPLIED <br />EQUIPMENT SHALL ONLY BE COMPLETED TO THE POINT INDICATED <br />ELSEWHERE ON THE DRAWINGS. <br />8. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR CONFORMITY TO ALL <br />LOCAL CODES AND ORDINACES, THE STATE CALIFORNIA ELECTRICAL <br />SAFETY ORDERS, THE NEC AND ANY ADDITIONAL JURISDICTION RELATING <br />TO THE WORK. <br />9. ELECTRICAL CONTRACTOR SHALL INCLUDE ALL FEES, INCLUDING <br />CONNECTION FEES AND SERVICES CHARGES, AND SHALL FURNISH <br />ALL PERMITS REQUIRED FOR THE ELECTRICAL SYSTEM, <br />10. IN THE EVENT OF A CONFLICT OR INCOSISTENCY BETWEEN ITEMS <br />INDICATED ON THE PLANS AND/OR SPECIFICATIONS OR WITH CODE <br />REQUIREMENTS, THE NOTES, SPECIFICATIONS OR CODES WHICH <br />ESTABLISH AND PRESCRIBE THE MORE COMPLETE WORK OR THE <br />HIGHER STANDARD SHALL PREVAIL. <br />—�� CIRCUIT BREAKER ® CIRCUIT BREAKER PANELBOARD 277/480V FLUORESCENT LIGHT FIXTURE —E— EMERGENCY CIRCUIT/CONDUIT <br />O DOWN LIGHT FIXTURE - VARIATION ®STRIP LIGHT <br />MAIN SERVICE SWITCHBOARD —(E)— EXISTING CIRCUIT/CONDUIT <br />STAGGERED STRIP FLUORESCENT <br />GROUND CONNECTION LUMINAIRE - — -- - CONDUIT UNDER SLAB OR BELOW GRADE <br />LP -1 PANEL DESIGNATION, PANEL ' LP -1 ' <br />WALL MOUNTED DUPLEX GROUNDING RECEPTACLE I—Q FLUORESCENT FIXTURE, WALL BRACKET — OHE — OVERHEAD ELECTRICAL LINE <br />NEMA 5-20R AT 18" AFF JON � TELEPHONE OUTLET BOX MOUNTED AT 18' AFF <br />JOIN WITH (1) 3/4" CONDUIT TO TELEPHONE <br />{ QUADRUPLEX (DOUBLE DUPLEX) GROUNDING BOARD/ CABINET (COMBINE TWO OUTLETS PER FO WALL MOUNTED FIXTURE SMOKE DETECTOR <br />�V RECEPTACLE NEMA 5-20R AT 18" AFF LON 3/4"C, THREE PER 1" C.) <br />WALL PACK FIXTURE ��.®_ FUSED SWITCH <br />WALL MOUNTED DUPLEX GROUNDING RECEPTACLE DATA OUTLET BOX MOUNTED AT III" AFF LON <br />W/ GFI NEMA 5-20R AT 18" AFF UON `a WITH (1") 3/4"C. TO CEILING SPACE. 1=� EMERGENCY LIGHT FIXTURE, WALL MOUNTED <br />MOTOR STARTER <br />ISOLATED GROUND DUPLEX RECEPTACLE �� FLEX CONDUIT <br />NEMA 5-20R WALL MOUNTED AT 18" AFF f EXIT LIES FIXTURE, SHADED SECTOR <br />1/2" CONDUIT WITH 2 #12 WIRES INDICATES FACE, DIRECTIONAL ARROWS SPP POWER POLE <br />1/2 SWITCHED RECEPTACLE GROUND DUPLEX PD PULLBOX <br />HOME -RUN TO PANEL 'A' CIRCUITS 3 AND 5 I/^ TOGGLE SWITCH AT + 44" AFF SUBSCRIPTS <br />O FLUSH MOUNT FLOOR BOX DUPLEX RECEPTACLE A-3,5 INDICATE THE FOLLOWING: 2 -TWO POLE, <br />MANHOLE <br />JUNCTION BOX <br />NEMA 5-20R, GROUNDING TYPE 3 -THREE WAY, 4-4WAYS, a,b,c-NUMBER MH <br />Q OF SWITCHES <br />FLUSH MOUNT FLOOR BOX QUADRUPLEX �I 1:1FLUORESCENT LIGHT FIXTURE -VARIATIONS FEl, FUSIBLE DISCONNECT SWITCH AS NOTED <br />RECEPTACLE NEMA 5-20R, GROUNDING TYPE L-1 �qM MANUAL DISCONNECT SWITCH WITH THERMAL COMBINATION MOTOR STARTER AND DISCONNECT <br />OVERLOAD PROTECTION. SWITCH WITH HOA SWITCH, NEMA SIZE 1, AND <br />FLUSH MOUNT FLOOR BOX TELEPHONE OUTLET © SEVEN DAY TIME CLOCK FUSES. <br />® FLUSH MOUNT FLOOR BOX DATA OUTLETTELEPHONE BACKBOARD/CABINET SAFETY DISCONNECT SWITCH AS NOTED <br />FLUSH MOUNT FLOOR BOX ISOLATED GROUND _ CT 12x4 CABLE TRAY: 12 INCHES WIDE BY 4 INCHES <br />RECEPTACLE NEMA 5-20R FLUORESCENT FIXTURES WITH F1 LIGHT FIXTURE DESIGNATION. DEEP <br />ELECTRICAL PANEL FLUSH MOUNT TANDEM WIRING 64 FIXTURE "Fl", 64 WATTS. <br />FLUORESCENT FIXTURE WITH CONDUIT COSEALED ABOVE CEILING OR <br />—- ELECTRICAL PANEL SURFACE MOUNT LA EMERGENCY CIRCUIT IN WALL <br />I� CIRCUIT BREAKER PANELBOARD 120/208V Pacific General, Irlc. REVISIONS �+ <br />NO. DATE BY COMMENTS SHELL OIL COMPANY <br />ENGINEERING/ARCHITECTURAL SERVICES <br />23331 EI Toro Road Suite 217 -- - I HOUSTON, TEXAS <br />Lake Forest, California 92630 --- <br />TEL: (714) 770-2770 • FAX: (714) 770-1252 <br />DESIGNED: R.M.L. pfESSp <br />ELECTRICAL PLAN <br />o PONq I.. -. <br />DRAWN BY: ��Oy M. <F�m�� PLANS PREPARED BY, 2494 FREMONT ST. & FILBERT ST. <br />P 6-30-99 <br />CHECKED BY: J.O. E 014840 A & S ENGINEERING STOCKTON, CALIFORNIA <br />R.M.L. EX. <br />PLANNING ENGINEERING CONSTRUCTION MANAGEMENT SCALE:NONE WIG 204-7524-1808 <br />PROJECT NO. * * 45 QUAIL COURT, SUITE 303 <br />5AS06 J CP P WALNUT CREEK, CALIFORNIA 94596 DATE: DRAWING NO. <br />FII.F N0. Tat£oCTR4�'.� PNONE: 510-933-0578 FAX: 510-933-0588 03-16-95 ^Llrrr nr E1 <br />SAS06EI <br />