Laserfiche WebLink
II <br />N <br />LU <br />c7] <br />J � <br />�I <br />LL <br />I <br />I <br />I <br />I <br />IEXISTING TRAFFIC <br />SIGNAL & STREET <br />ILIGHT TO REMAIN <br />I <br />I <br />s�SITE PLAID GENERAL NOTES <br />IN cQ N 1. INSULATION OF CONDUCTORS IN AND UNDER GASOLINE PUMP AREA <br />SHALL BE LISTED AND APPROVED FOR GASOLINE/OIL RESISTANT TYPE. <br />2. USE EXISTING UNDERGROUND CONDUITS WHERE APPLICABLE AND <br />PERMITTED BY CODES, CONTRACTOR TO VERIFY REQUIREMENTS. <br />3. CONTRACTOR TO VERIFY VOLTAGE OF EXISTING EQUIPMENT TO BE <br />RECONNECTED OR EQUIPMENT FURNISHED BY OTHERS, PRIOR TO <br />HOOK—UP. ANY DISCREPANCY BETWEEN EQUIPMENT AND PLANS <br />BE CALLED TO THE ATTENTION OF THE ENGINEER. <br />4. ALL SITE CONDUCTORS SHALL BE #10 THWN CU., UNLESS NOTED <br />OTHERWISE. <br />5. CONTRACTOR SHALL VERIFY QUANTITY AND SIZE OF ALL CONTROL WIRES. <br />\ \___ EXISTING POWER <br />POLE TO REMAIN <br />EXISTING TRAFFIC <br />SIGNAL TO REMAIN <br />................ .......®... <br />MIN -101010001 <br />10 5 0 10 2.0 <br />1"=10'-0" SCALE n FEET <br />Pacific General, Inc. <br />ENGINEERING/ARCHITECTURAL SERVICES <br />23331 EI Toro Road • Suite 217 <br />Lake Forest, California 92630 <br />TEL: (714) 770-2770 • FAX: (714) 770-1252 <br />DESIGNED: <br />R.M.L. QPOFESS�ONA, <br />DRAWN BY:_ <br />' <br />4F <br />CHECKED BY: J.O. 014540 <br />R.M.L. P. 6-30-99 <br />PROJECT NO. I \\*\ , <br />FILE NO. <br />5AS06E2 <br />N0. DATE BY <br />6. COORDINATE EXACT LOCATION FOR P.O.S. EQUIPMENT AND PROVIDE <br />ALL REQUIREMENTS EOR NEW DISPENSERS INSTALLED, <br />7. MINIMUM SITE CONDUIT SIZE SHALT- BE 3/4" LLO.N.. PROVIDE PULL— <br />WIRE IN ALL CONDUIT ONLY (C.O.) RUNS. USE RGS UNDERGROUND <br />AND AT DISPENSERS. USE RGS WHERE EXPOSED AND SUBJECT TO <br />PHYSICAL ABUSE. USE RGS, EMT, OR FLEXIBLE CONDUIT IN BUILDING <br />USE LIQUIDLIGHT FLEX AT CONNECTION TO MOTORS. <br />I SITE PLAID KEY NOTES <br />F I AREA HIGHLIGHTED IS A CLASS 1, DIVISION 2 HAZARDOUS AREA, AND <br />SHALL CONFORM TO NEC ART, 500, 501, 514, AND NFPA 30A, <br />ALL CONDUITS ENTERING OR LEAVING THIS AREA SHALL HAVE <br />SEAL -OFF FITTINGS ON BOTH ENDS OF THE RUN. <br />I21 PROVIDE AND INSTALL ONE (1) EXPLOSION PROOF JUNCTION BOX <br />L`WITHIN EACH NEW FUEL DISPENSER FOR DISPENSER POWER, LIGHT, <br />CONTROL, SIGNAL MONITORING, AND CARD READER. CONTRACTOR TO <br />MAKE CONNECTION TO FUEL DISPENSER PUMP AND LIGHTS. VERIFY <br />REQUIREMENTS AND COMPLY. <br />J (2) 3/4"C (ONE FOR DISPENSER POWER & LIGHT WITH CONDUCTORS; <br />ONE FOR DISPENSER CONTROL/MONITORING/CARD READER WITH <br />CONTROL WIRES) 10 ELECTRICAL GUTTER IN LUBE BAY AREA. USE <br />EXISTING CONDUITS WHERE APPLICABLE AND PERMITTED BY CODES. <br />VERIFY REQUIREMENTS, AND COMPLY. <br />I� PROVIDE AND INSTALL NEW SUB—PANEL "B" FOR NEW MULTI—PRODUCT <br />[J FUEL DISPENSERS AND UNDERGROUND TANKS. SEE PANEL SCIIFDUI.E <br />ON DWG. "E1" FOR ADDITIONAL REQUIREMENTS. <br />EXISTING MAIN ELECTRICAL PANEL "A" TO REMAIN. MODIFY CIRCUITS <br />AS SHOWN ON PANEL SCHEDULE, SEE DWG. "E-1". <br />©REPLACE EXISTING FUEL TANK AND DISPENSER CONTROL AND <br />MONITORING UNITS WHERE REQUIRED, VERIFY AND COMPLY TO ALL <br />REQUIREMENTS. <br />REMOVE EXISTING PAPER TOWEL DISPENSER FROM LUBE BAY AREA <br />TO ACCOMODATE NEW SUB—PANEL "B" (FOR FUEL TANKS & <br />DISPENSERS). VERIFY REQUIREMENTS. <br />® PROVIDE AND INSTALL J—BOX FOR TANK TURBINE POWER. <br />L9D FEEDERS WIRED THROUGH PUMP RELAY STARTER. VERIFY ALL <br />REQUIREMENTS. <br />10 PROVIDE AND INSTALL J—BOX FOR TANKS SENSOR, MONITOR & <br />E <br />LEAK DETECTOR, VERIFY REQUIREMENTS. <br />11 (1) 3/4"C + CONTROL WIRES TO MAIN FUEL CONTROL PANEL GUTTER. <br />VERIFY REQUIREMENTS. <br />12 EXISTING 2" UNDERGRO61ND CONDUIT FROM POWER POLE TO LUBE <br />BAY MAIN SERVICE. CONTRACTOR TO OBTAIN EXISTING SITE UTILITY <br />PLAN FROM THE CITY TO VERIFY THE EXISTING 2" SERVICE CONDUIT <br />ROUTING. REROUTE AND EXTEND THE SERVICE CONDUIT WHERE <br />REQUIRED TO ACCOMODATE THE NEW UNDERGROUND FUEL STORAGE <br />TANK INSTALLATION. VERIFY ALI- REQUIREMENTS, AND COMPLY. <br />REVISIONS <br />COMMENTS <br />PLANS PREPARED BY. <br />A & S ENGINEERING <br />PLANNING ENGINEERING CONSTRUCTION MANAGEMENT <br />45 QUAIL COURT, SUITE 303 <br />WALNUT CREEK, CALIFORNIA 94596 <br />PHONE: 510-933-0578 FAX 510-93:3-0588 <br />SHELL OIL COMPANY <br />HOUSTON, TEXAS <br />ELECTRICAL SITE PLAN <br />2494 E. FREMONT STREET & FILBERT STREET <br />STOCKTON, CALIFORNIA <br />SCALE: 1"=10'-0" I WIC it 204-7524-1808 <br />DATE: 03-16-95 1 DRAWING NO. E2 <br />SHEET <br />