My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REMOVAL_1986
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
4343
>
2300 - Underground Storage Tank Program
>
PR0232095
>
REMOVAL_1986
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2021 1:29:09 PM
Creation date
11/5/2018 10:08:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
REMOVAL
FileName_PostFix
1986
RECORD_ID
PR0232095
PE
2381
FACILITY_ID
FA0010425
FACILITY_NAME
Pacific Paper Tube
STREET_NUMBER
4343
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95215
CURRENT_STATUS
02
SITE_LOCATION
4343 E FREMONT ST
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\F\FREMONT\4343\PR0232095\REMOVAL 1986.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
170
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
466700 ENVIRONMENTAL HEALTH TITLE 22 <br /> (P• 1800.80) (Rpitdr at Na 2-1.1246) <br /> (1) Type is If the waste or other material is a millable solid,the sample shall <br /> be passed duectly,or shall be milled to pass,through a No.10 (two millimeter) <br /> standard sieve before it is analyzed. If the sample contains non-friable solid <br /> particles which do not pass directly through a No. 10 sieve and which are <br /> extraneous and irrelevant as hazardous constituents to the waste or other <br /> material,they shall be removed to the extent feasible by mechanical means and <br /> discarded.Solids which remain in the waste or other material after removal of <br /> the aforesaid extraneous particles shall be milled to pass through a No.10 sieve <br /> and shall then be combined and mixed well with the solids which passed <br /> through the sieve without milling. The reconstituted sample shall then be <br /> analyzed as prescribed in this section. <br /> (2) Type ii:If the waste or other material is a filterable mixture of liquid and <br /> solids in which the solids constitute five-tenths (0.5) percent byy weight or <br /> greater of the sample, the liquid and solids shall be separated by filtration <br /> through a 0.45 micron membrane filter.The filtrate so obtained is to be desig- <br /> nated as Initial Filtrate.Its volume is determined,and it is retained.The sepa- <br /> rated solids shall be sieved in a No. 10 sieve and any nonfriable extraneous <br /> particles of the kinds described in subsection (c) 1) which do not pass through <br /> the sieve shall be removed to the extent feasible by mechanical means and <br /> discarded. The solids which remain after removal of the extraneous particles <br /> shall be milled to pass through a No.10 sieve and shall be recombined with solids <br /> which passed through the sieve without milling.This recombined solid material <br /> shall be extracted following the procedure in subsection (f). A ratio of 10 <br /> milliliters of extraction solution per gram of solid shall be utilized with appropri- <br /> ate modifications for extraction vessel size. After completion of solids extrac- <br /> tion,the filtered extractant is combined with Initial Filtrate mixed thoroughly <br /> and anlyzed as described in subsection (f) 3). <br /> (3) Type iii:If the waste or other material is a nonfilterable and nonmillable <br /> sludge,slurry,or oily,tarry or resinous material,it shall be analyzed as received <br /> unless it contains non-friable extraneous and irrelevant solid particles of the <br /> ldnds described in paragraph (c)(1) of this section. If it contains such solid <br /> particles and they are Much size as not to pass through a No. 10 sieve, they <br /> shall be removed to the extent feasible by mechanical means and discarded. <br /> The remainder of the sample shall be analyzed as prescribed in this section. <br /> (4) If it is necessary to dry a solid sample or the solids fraction of a sample <br /> be ' <br /> re sieving,milling or removal of extraneous solids, or if a sample is dried <br /> prior to analysis,all weight losses due to drying shall be determined,and these <br /> losses and the conditions of drying shall be reported. <br /> (d) If the waste or other material is a liquid containing less than five-tenths <br /> (0.5) percent by weight of undissolved solids,it shall not be subject to the WET <br /> procedure, but shall be analyzed directly for the substances listed in Section <br /> 66699.The waste shall be classified as a hazardous waste if the total concentra- <br /> tion in the waste of any substances listed in Section 66699 exceeds the TTLC <br /> value given for that substance. If,however,the total concentration is less than <br /> the TTLC but exceeds the STLC when expressed on a milligrams per liter basis, <br /> the waste or other material shall be filtered through a 0.45 micron membrane <br /> filter, the solids discarded and the filtrate shall be analyzed directly for the <br /> substances listed in Section 66699. The waste shall be classifed as a hazardous <br /> waste if the concentration in the filtrate of any of the substances listed in Section <br /> 66699 exceeds the STLC value given for that substance. <br />