Laserfiche WebLink
Tr=22 ENVIRONMENTAL HEALTH 466700 <br /> (RpMgr IL Na 3-44ZA) (p. 1800.81) <br /> (e) The WET extraction solution shall consist of 0.2 M sodium citrate at pH <br /> 5.0 * 0.1,which ispprepared by titrating an approppnate amount of analytical <br /> grade citric acid in deionized water with 4.0 N NaOH,except that the extraction <br /> solution for the determination of chromium (VI) shall consist of deionized <br /> water. <br /> (f) The extraction procedure shall be as follows: <br /> (1) Fifty grams of sample,or less if it is a type ii sample prepared pursuant <br /> to subsection (c)(2),obtained pursuant to subsection (c) or (d) of this section <br /> shall be placed in a cleanpolyethylene or glass container designated the Treat- <br /> ment,capable of physically withstanding the extraction procedure and which <br /> was rinsed previously with,in succession,an aqueous 1:1 ratio by volume nitric <br /> acid solution and deionized water.If the extract will be analyzed for any of the <br /> organic substances listed in Section 66699(c), a glass container shall be used. <br /> Furthermore,a container of the same size,shape and material shall be used for <br /> an extraction designated as the Blank,which shall be carried through the same <br /> procedure as the Treatment,but without addition of the sample. <br /> (2) Five hundred milliliters of extraction solution,or less if the waste sample <br /> is a type ii sample repared pursuant to subsection (c)(2) shall be added to the <br /> Treatment and Blank containers,which shall be then fitted with covered air <br /> scrubbers extended well into the extraction solutions and flushed vigorously <br /> with nitrogen gas for 15 minutes so as to remove and exclude atmos heric <br /> oxygen from the extraction medium. If the sample is to be analyzed for any <br /> volatile substance, such as trichloroethylene, the sample shall be added after <br /> deaeration with nitrogen to avoid volatilization loss.After deaeration the con- <br /> tainers shall be quickly sealed with tightly fitting caps and agitated,using a table <br /> shaker,an overhead stirrer or a rotary extractor,operated at a speed which shall <br /> maintain the sample in a state of vigorously apftated suspension. Required <br /> equipment is described in test method 1310 in 'Test Methods for Evaluating <br /> Solid Waste,Physical/Chemical Methods",SW 846,2nd edition U.S. Environ- <br /> mental Protection Agency, 1982.The temperature during the extraction shall <br /> be maintained between 20 and 40 degrees centigrade.After 48 hours of extract- <br /> ing,the contents of the Treatment and Blank containers shall be either filtered <br /> directly or centrifuged and then filtered.Filtering shall be through a medium <br /> porosity prefilter and then through a 0.45 micron membrane filter, using a <br /> clean, thick-walled suction flask. For coarser solids, prefiltration shall not be <br /> necess . Pressure filtration shall be an optional alternative to vacuum filtra- <br /> tion.If�e extracts are fust centrifuged,glass or polyethylene bottles shall be <br /> used as prescribed for extraction. For very fine solids,centrifuging at as high <br /> as 10,000 X G may be necessary. After centrifugation, the liquids shall be de- <br /> canted,prefiltered if necessary,and then passed through a 0.45 micron mem- <br /> brane filter. All filters shall be of low and identified extractable heavy metals, <br /> fluoride and organic chemicals content. <br /> (3) If the filtered extracts are to be analyzed only for the metal elements <br /> listed in Section 66699(b),the filtered extracts from the Treatment and Blank <br /> shall be transferred to clean polyethylene bottles and acidified with nitric acid <br /> to five percent by volume acid content soon after each extract is filtered. For <br /> those wastes or waste materials classified under subsection (c)(2), the Treat- <br /> ment shall be the Initial Filtrate combined with the extract generated by the <br /> WET extraction of the initially separated solids. Similarly the Blank in this <br /> instance shall be the filtrate generated by the WET Blank accompanying the <br /> initially separated solids,to which is subsequently added a volume of deionized <br />