My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 2006 - 2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRENCH CAMP
>
5777
>
2300 - Underground Storage Tank Program
>
PR0505746
>
BILLING 2006 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2021 10:20:42 PM
Creation date
11/5/2018 10:16:20 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
2006 - 2012
RECORD_ID
PR0505746
PE
2361
FACILITY_ID
FA0006977
FACILITY_NAME
76 EXPRESS TIGER NO 1
STREET_NUMBER
5777
Direction
S
STREET_NAME
FRENCH CAMP
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
19302037
CURRENT_STATUS
01
SITE_LOCATION
5777 S FRENCH CAMP RD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\F\FRENCH CAMP\5777\PR0505746\BILLING 2006 - 2012.PDF
QuestysFileName
BILLING 2006 - 2012
QuestysRecordDate
2/13/2018 7:47:07 PM
QuestysRecordID
3792345
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
l <br /> UNIFIED PROGRAM CONSOLIDATED FORM <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN (Page 2 of 2) <br /> VI.UNDER DISPENSER CONTAINMENT(UDC)MONITORING <br /> 1. UDC MONITORING IS PERFORMED USING THE FOLLOWING METHOD 490.54a <br /> ❑ 1.CONTINUOUS ELECTRONIC MONITORING ra 2.FLOAT AND CHAIN ASSEMBLY El 3.ELECTRONIC STAND-ALONE 490-54b❑4.NO DISPENSERS 099.OTHER(S ify): r <br /> PANEL MANUFACTURER: F(.�✓a-- 490-55 MODEL#--------------- -- 490.56. <br /> LEAK SENSOR MANUFACTURER: 490 57 MODEL#(S): — 49ass <br /> DETECTION OF A LEAK INTO THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS ❑ a.YES CR:tf.NO 490-59 <br /> UDC LEAK ALARM TRIGGERS AUTOMATIC PUMP SHUTDOWN 93-a.YES ❑b.NO 490-60. <br /> FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a.YES Q-*NO 490-61 <br /> UDC MONITORING STOPS THE FLOW OF PRODUCT AT THE DISPENSER. G].etYES ❑b.NO 490-62 <br /> 2.UDC CONSTRUCTION IS [SINGLE-WALLED ❑2.DOUBLE-WALLED 490-63 <br /> IF DOUBLE WALLED: 490-64a <br /> UDC INTERSTITIAL SPACE IS MONITORED BY: ❑ 1.LIQUID ❑2.PRESSURE ❑3.VACUUM <br /> A LEAK WITHIN THE SECONDARY CONTAINMENT OF THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS ❑a YES ❑b.NO 490-64b <br /> VII.PERIODIC SYSTEM TESTING <br /> ❑ 1. ELD TESTING: THIS FACILITY HAS BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT ENHANCED 490-65. <br /> EAK DETECTION ELD MUST BE PERFORMED. PERIODIC ELD IS PERFORMED EVERY 36 MONTHS AS REQUIRED. 23 CCR 2644.1 <br /> 21.SECONDARY CONTAINMENT COMPONENTS ARE TESTED EVERY 36 MONTHS. 490-66 <br /> SPILL BUCKETS ARE TESTED ANNUALLY. 49o.67 <br /> VIII.RECORDKEEPING <br /> The following monitoring/maintenance records are kept for this facility: <br /> larm logs 49"& ❑Visual Inspection Records 490.68b EJ*Tnnk integrity testing results 490-68c <br /> Lj SIR testing results(and supporting documentation records). 490-69d ❑ Tank gauging results(and supporting documentation records). 490-68e <br /> ❑ATG Testing results(and supporting documentation records).49o-68f ❑ Corrosion Protection 60-day logs 49o-68g <br /> uipment maintenance and calibration records. 490-6ah <br /> IX.TRAINING <br /> ersonnel with UST monitoring responsibilities are familiar with all of the following documents relevant to their job duties. 49069a <br /> REFEUNCE DOCUMENTS MAINTAINED AT FACILITY(Check all that apply) <br /> Ra-MIS UNDERGROUND STORAGE TANK MONITORING PLAN(Required)490-69b <br /> [?OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT(Required)49"9c <br /> O'CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS 49o-69d <br /> 92�IFORNIA UNDERGROUND STORAGE TANK LAW 49"% <br /> STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL AND <br /> STATISTICAL INVENTORY RECONCILIATION"490-69f <br /> ❑ SWRCB PUBLICATION:"UNDERSTANDING AUTOMATIC TANK GAUGING SYSTEMS"490-69g <br /> ❑ OTHER(Specify):M69h•M69; <br /> ERAis facility has a"Designated UST Operator"who has passed the California UST System Operator Exam administered by the International Code Council(ICC). <br /> e"Designated UST Operator"will train facility employees in the proper operation and maintenance of the UST systems annually,and within 30 days of hire.This <br /> training will include,but is not limited to,the following: <br /> > Operation of the UST systems in a manner consistent with the facility's best management practices <br /> ➢ The facility employee's role with regard to the monitoring equipment as specified in this UST Monitoring Plan <br /> The facility employee's role with,regard to spills and overfills as specified in the UST Response Plan <br /> ➢ Names of contact person(s)for emergencies and monitoring alarms.490-70 <br /> X. COMMENTS/ADDITIONAL INFORMATION <br /> Provide additional comments here or indicate how man pages with additional information on specific mom nng procedur a attached to this plan.490-71 <br /> 6LW I` <br /> XII.PERSONNEL RESPONSIBILITIES <br /> The UST Owner/Operator is responsible for ensuring that 1)the daily/routine UST monitoring activities and maintenance of UST leak detection equipment covered by <br /> this plan occurs,2)all conditions that indicate a possible release are investigated,and 3)all monitoring records are maintained properly. <br /> The folio rson(s)a e res nsib a for performing the monitoring and equipment maintenance: <br /> NAME 490-72 TITLE 490-73 <br /> NAME 490.74 TITLE 490-75 <br /> The Designated Operator shall perform a monthly visual inspection of the facility, provide a report to the owner/operator, and inform the owner/operator of any <br /> conditions that need follow-up action. <br /> XII.OWNERIOPERATOR SIGNATURE <br /> CERTIFICATION:I certify that the information provided herein is true and accurate to the best of my knowledge. <br /> APPLICANT SIGNATURE Q 490-76 DATE: 490-77 <br /> ( - (g- <br /> P l 0,, /Q. 2 rh ,n ! r 3.Authonzed Re atic f , <br /> APPLICANT NAME(print): /:/� � 49040- APPLICANT T� 490-79 <br /> UPCF UST-D(12/2007)3/4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.