Laserfiche WebLink
0 . <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sjgov.oro/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> GEMCO RIPON TRUCK PLAZA INC 1022 E FRONTAGE RD, RIPON March 06, 2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 315 HSC 25291(e) Water in secondary containment not removed, analyzed, and properly disposed of (pre-Jul 2003). <br /> Liquid was observed in the 91 STP sump, UDC 1/2 & UDC 3/4. If water could enter into the secondary containment <br /> by precipitation or infiltration, it must be removed and disposed of properly. The service technician removed less <br /> than half a gallon of liquid from all of the above sumps. Ensure that all sumps and annular spaces are maintained <br /> free of liquid. <br /> This was corrected on site. <br /> This is a Class II violation. <br /> 318 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi. <br /> The 91 VMI line leak detector failed to detect a leak when tested. All line leak detectors shall be capable of <br /> detecting a 3-gallon per hour leak at 10 psi. The service technician replaced the siphon jet and adjusted the leak <br /> detector, retested it, and it passed. <br /> This was corrected on site. <br /> This is a Class II violation. <br /> 321 CCR 2635(b)(2)Overfill prevention was overridden. <br /> The mechanical overfill prevention device on the 91 UST is potentially overridden by the presence of a long <br /> cylindrical object placed in the drop tube. The technician onsite (Zane Nimmo) indicated that the object was <br /> approximately 3 inches below the flapper valve and at least 2 pounds in weight. The technician onsite attempted to <br /> remove the object but was unsuccessful. At this time it is unclear if the foreign object is affecting the flapper valve. <br /> Immediately remove the foreign object, if the object can't be removed immediately, there is a possibility that the 91 <br /> UST system may be red tagged to prevent fuel inputs. Take all necessary precautions to prevent this in the future. <br /> Submit proof of correction to the EHD. <br /> This is a repeat violation, Class ll. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by April 5, 2017. <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br /> applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br /> Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br /> Notes: Received a copy of the secondary containment test report for testing conducting on May 27, 2015. <br /> FA0000650 PR0231604 SCO01 03/06/2017 <br /> EHD 23-01 Rev.09/22/16 Page 6 Of 7 Underground Storage Tank Program OIR <br />