My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016-2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRONTAGE
>
1002
>
2300 - Underground Storage Tank Program
>
PR0231604
>
COMPLIANCE INFO_2016-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/10/2022 3:22:51 PM
Creation date
11/5/2018 10:21:46 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2017
RECORD_ID
PR0231604
PE
2361
FACILITY_ID
FA0000650
FACILITY_NAME
GAS & SHOP
STREET_NUMBER
1002
STREET_NAME
FRONTAGE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
26102012
CURRENT_STATUS
01
SITE_LOCATION
1002 FRONTAGE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\F\FRONTAGE\1022\PR0231604\COMPLIANCE INFO.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
71
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page_of_ <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: D Sump Manufacturer ®Industry Standard D Professional Engineer <br /> 0 Other(Specify) <br /> Test Method Used: D Pressure D Vacuum N Hydrostatic <br /> D Other(Specify) <br /> Test Equipment Used: CALDWELL LEVEL INDICATOR Equipment Resolution: .002 <br /> Sump# Sump# Sump#EAST D Sump#WEST XD <br /> REGULAR PREMIUM TRANSITION TRANSITION <br /> Sump Diameter: 36 in. 36 in. 3 ft. 4 It <br /> Sump Depth: 6 It 6 ft 45 in. 48 in. <br /> Sump Material: Fiberglass Fiberglass Fiberglass Fiberglass <br /> Height from Tank Top to Top of 18 in. 17 in. 1 ft/12 in. 16 in. <br /> Highest Piping Penetration; <br /> Height from Tank Top to Lowest 12 in. 12 in. 9 in. 14 in. <br /> Electrical Penetration: <br /> Condition of sump prior to testing: Dry dirty Dry dirty Wet dirty Dry dirty <br /> Portion of Sump Tested' 20 20 16 in. 18 in. <br /> Does turbine shut down when <br /> sump sensor detects liquid(both N Yes DNo DNA N Yes DNo DNA N Yes DNo DNA N Yes DNo DNA <br /> product and water?' <br /> Turbine shutdown response time 20 sec. 20 sec. 20 sec. 20 sec. <br /> Is system programmed for fail-safe <br /> shutdown? ® Yes DNo DNA N Yes ❑No [INA N Yes ❑No DNA N Yes 0N DNA <br /> Was fail-safe verified to be g.Yes D No DNA B"fifes DNo DNA �es 0 No 0NA &Yes DNo DNA <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and starting 5 min. 5 min. 5 min. 5 min. <br /> test: <br /> Test Start Time: 8:45 9:05 12:55 11:00 <br /> initial Reading(Rj: .001 .001 .001 •001 <br /> Test End Time: 9:15 9:35 1:25 11:30 <br /> Final Reading(RF): .001 .001 .001 .001 <br /> Test Duration: 30 min. 30 min. 30 min. 30 min. <br /> Change in Reading(RF-R): 0 0 0 0 <br /> Pass/Fail Threshold or Criteria: Pass Pass Pass Pass <br /> Test Result. N Pass 0 Fail N Pass 0 Fail N Pass 0 Fail N Pass 0 Fad <br /> Was sensor removed for testing? N Yes 0 No D NA N Yes DNo DNA Eyes DNo DNA N Yes DNo DNA <br /> Was sensor properly replaced and tYes 0 No DNA Yes 0 No DNA rales DNo DNA I gYes DNo DNA <br /> verified functional after testin ? <br /> Comments—(include information on repairs made prior to testing and recommended follow-up for jailed tests) <br /> 1 safe was verified on T . <br /> MAR 0 6 2017 <br /> N,!R0 NMf=NTAL HEALTH <br /> DEPARTMENT <br /> If the entire depth of the sump is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.