A B C D E F <br /> GENERAL NOTES <br /> S P I L L C O N T A I N M E N T S U M P S P I L L C 0 N T A I N M E N T S U M P t. ALL UNUSED TANK OPENINGS SHALL BE TIGHTLY <br /> SECURED WITH PIPE PLUG, INSTALLED IN ACCORDANCE <br /> — 2" SINGLE WALL FUTURE PHASE II VAPOR RECOVERY PIPE (CAPPED) <br /> WITH MANUFACTURERS SPECIFICATIONS, <br /> 1 6 I' SUMP CONDUIT PENETRATION 2_ ALL LOCKABLE CAPS SHALL HAVE PADLOCKS KEYED <br /> 1 M1" STEEL PLUG TYP JUNCTION BOX (TYR BOTH SUMPS) ALIKE WITH THE EXCEPTION OF THE "FILL" CAP <br /> (TYR) <br /> IN <br /> TANK LEVEL PROBE RISER & CAP 3 ACCORDANCE WITHTANKS SHALL BET ESTED MANUFACTURERSANDAILED RECOMMENDA- 1 <br /> 4"x M1" FILL CAP AND ADAPTOR -""'"' 4" STEEL PLUG (NP) TIONS AS WELL AS LOCAL ORDINANCES-SEE DWG.. J-0.1. <br /> 4. ALL CONTAINMENT SUMP ASSEMBLIES SHALL BE <br /> PIDERGLASSED INSIDE & OUTSIDE TO TANK RING AND <br /> CAPABLE OF WITHSTANDING HYDROSTATIC TESTING. <br /> SUMP LEAK DETECTOR SENSOR CONTAINMENT SUMP ASSEMBLIES WILL BE INSTALLED <br /> BY AMERICAN CONTAINMENT WHICH WILL ACT AS A <br /> n 3/4' SUMP CONDUIT PENETRATION SUBCONTRACTOR TO THE GENERAL CONTRACTOR. <br /> CALL a 8 <br /> 3/4" CONDUIT FOR SUBMERSIBLE PUMP POWER (SEE NOTE 8) <br /> GENERAL S <br /> CONTRACTOR WILL PERF0) 555-6785 TO ORM HYDROSTATIC <br /> n ` 2" BALL VALVE TEST ASSOFTERCIATED <br /> INSTALLING PENETRATION FITTINGS <br /> N I AND ASSOCIATED PIPING / CONDUIT. <br /> m 2"x24" M/S x FEMALE FLEXING CONNECTOR (2 TYR) <br /> 5. ASSURE UNUSED PORTS ARE PLUGGED ON <br /> I � / 2" SUMP PIPING PENETRATION TURBINE AND LEAK DETECTOR, <br /> 4" STEEL PLUG (NP) i" CONDUIT (SEE NOTE 8) 2" SINGLE WALL FIBERGLASS TANK VENT 6. LOW AND HIGH VOLTAGE LINES SHALL BE RUN IN <br /> 3" SUMP PIPING PENETRATION SEPARATE DEDICATED CONDUITS. <br /> TANK ANNULUS SENSOR RISER & CAP 7. ALL STEEL PIPING INSIDE SPILL CONTAINMENT SUMP <br /> 1" CONDUIT FROM MONITOR PANEL TO J-BOX (SEE NOTE B & 15) 2" FIBERGLASS PRODUCT PIPING UNE WITH ASSEMBLY SHALL BE SCH. 40 BLACK IRON, INCLUDING <br /> 36" DIA. FILL BOX & COVER WITH SPILL CONTAINMENT I SEE DETAIL J-1.1 I 3" FIBERGLASS SECONDARY CONTAINMENT PIPE ALL 4" RISERS. (NO GALVANIZED PIPING) <br /> FILL BOX WITH DRAIN VALVE FILL I I 4" EXTRACTOR CAP 4"x4"x3"x2" EXTRACTOR VALVE 8. ROUTE CONDUITS ALONG INSIDE PERIMETER OF SUMP TO <br /> SEE DETAIL J-1.1 FILL MANWAY & CONTAINMENT SUMP SUBPUMPMANWAY & ASSEMBLY - PLUG UNUSED OPENING 2 TYP PROVIDE EASE OF ACCESS TO PIPING IN THE FUTURE. <br /> 12" 24" SLOPE (TYP) CONryJNMENT SUMP ( ) 12" FOR CONDUIT SCHEMATIC SEE DWG. J-8. <br /> 4" MIN, 6" MAX, CLEARANCE 36" DIA SUB-PUMP MANWAY <br /> 2" CROWN (TYR) FROM CAP TO LID / 8"MIN. TO 18" MAX. CLEARANCE FROM AC PAVING <br /> I - / 9. All JUNCTION BOXES TO BE EXPLOSION PROOF WITH <br /> _ MANWAY 70 RISER CAP & SUB-PUMP TYP BATH SIDES) UNION HUBS, CROUSE-HINDS GUAG7775. JUNCTION <br /> d BOXES ON SUMP WALL SHOULD DE MOUNTED AS <br /> d — HIGH AS POSSIBLE FOR FRSE OF SERVICING. <br /> 10. ALL CONDUITS TO HAVE SEAL-OFFS PER LATEST EDITION <br /> OF THE NATIONAL ELECTRICAL CODE. <br /> INSTALL MECHANICAL LEAK DETECTOR PER <br /> 4' BLACK IRON RISER BY CONTRACTOR I MANUFACTURERS INSTRUCTIONS PAVIN BASE 11. USE CABLE CONNECTOR FITTINGS (CROUSE-HINDS CCB OR <br /> JUNCTION BOX (TYP BOTH SUMPS 3"x2" REDUCING TEST BOOT SEE NOTE 16 (TYP APPROVED EQUAL AT MONITOR <br /> EE NOTE 9 <br /> ( ) ( Y BOH SIDES) ) & LEVEL GAUGE CABLE <br /> S ) CONNECTIONS TO J-BOXES & PIPE FITTINGS. <br /> EYESEAL OFF (TYP BOTH SUMPS) <br /> 3/4" SUMP CONDUIT PENETRATION <br /> 2 "_ 3/4" CONDUIT FOR SUBMERSIBLE PUMP MINIMUN 5'-0"-MAXIMUM 7'-02. ALL CONDUIT AND PIPING TO PENETRATE SUMPS <br /> _ I (SEE NOTE 8) SEE SITE SPECIFIC PERPENDICULAR TO SUMP WAIL. 2 <br /> 1" SUMP CONDUIT PENETRATION 1" SUMP <br /> BURIAL DEPTH CALCULATION 13. WHEN INSTALLING FILL BOX, CONTRACTOR IS TO ASSURE <br /> CONDUIT PENETRATION 3" SUMP PIPING PENETRATION ON GENERAL PIPING PLAN THAT THE SPACE BETWEEN THE FILL BOX SKIRT AND THE <br /> 1" CONDUIT FROM MONITOR PANEL 2" FIBERGLASS PRODUCT PIPING LINE WITH TOP OF THE CONTAINMENT SUMP IS EQUALLY SPACED <br /> TO J-BOX (SEE NOTE 8 & 15) — SEE NOTE ABOVE II 3" FIBERGLASS SECONDARY CONTAINMENT PIPE ALL AROUND. PROVIDE ADEQUATE SUPPORT FOR FILL <br /> DROP TUBE WITH OVERFILL PROTECTION 2" SINGLE WALL FIBERGLASS TANK VENT BOX DURING CONCRETE INSTALLATION SUCH THAT FILL_ <br /> 2" SUMP PIPING PENETRATION (TYP BOTH SIDES) BOX DOES NOT MOVE RELATIVE TO CONTAINMENT SUMP. <br /> 42" TANK COLLAR (TYR BOTH SUMPS) I I CONTAINMENT SUMP LID MUST BE INSTALLED ON TURBINE <br /> CONTAINMENT SUMP TO ASSURE THAT NO WATER ENTRY <br /> LOCATION FOR TANK HOLD DOWNS (4 TYR) 1 I CAN OCCUR. <br /> 14. ALL PIPING TO SLOPE DOWN TOWARD TANKS AT A <br /> MINIMUM OF 1/4" PER FOOT. <br /> I I I I 15. MONITOR CONDUIT MAY ENTER TURBINE SUMP FIRST <br /> _ DEPENDENT ON SITE ARRANGEMENT AND TANK <br /> - I I LOCATIONS. <br /> 16. UNCVAMP TEST BOOT AFTER TESTING SECONDARY PIPING, <br /> I I I II II I UNDERGROUND STORAGE TANKS <br /> I <br /> APPROVED <br /> DBLEW <br /> AREPERDWG. J-0.1, <br /> , MATERIALAFURN S14D <br /> BY 76 PRODUCT CO. <br /> SEE GENERAL ARRANGEMENT DRAWING FOR QUANTITY AND <br /> I I LOCATION OF TANKS. <br /> QIESLL FUEL STORAGE TANKS <br /> _ TANK SHALL BE INSTALLED PER SITE SPECIFIC BURIAL DEPTH <br /> 1 II CALCULATION AS SHOWN ON DRAWING J-0.1. TANKS MUST <br /> NOT BE BURIED DEEPER THAN 7 FEET, THERE SHALL BE <br /> II ( I I I 1O'-4„ 18 INCHES MIN. BETWEEN TANKS. <br /> — TANKS SHALL BE INSTALLED WITH A CRANE ONLY. <br /> OUTSIDE DIAMETER CRANE SHOULD BE ADEQUATELY SIZED TO <br /> ACCOMODATE TANK SIZES SPECIFIED ON THE GENERAL <br /> 1 ARRANGEMENT DRAWING AND WEIGHTS AS INDICATED IN THE <br /> 1 /4" THICK STRIKER PLATE UNDERTABLES HEREON. TANKS SHALL BE SET ON A FIRM BASE OF 12" <br /> - WASHED PEA GRAVEL AND SURROUNDED ON ALL SIDES BY A <br /> ALL TANK OPENINGS I I MINIMUM THICKNESS 18" OF WASHED PEA GRAVEL. <br /> (FURNISHED BY TANK MANUFACTURER) II = <br /> I I= CONTRACTOR SHALL INSTALL FILL RISER AND LEVEL TANK TO <br /> i I KEEP RISER STRAIGHT BEFORE PROCEEDING TO BACKFILL. <br /> PERSONNEL CHECKING LE/EL SHALL BE LOWERED TO TANK <br /> i <br /> =I I TOP IN SAFETY HARNESS, <br /> I I _ FOR ADDITIONAL INFORMATION SEE DWG. J-0.1, J-0.2, J-0.2A. <br /> - TANK SPECIFICATIONS <br /> *45 XERXES CORPORATION <br /> 4-6" — DIESEL TANK <br /> ly CAPACITY 10,000 GALS. --- <br /> ACTUAL 10,369 GALS <br /> _ 12" PEA GRAVEL TANK BED (SEE J-0. 1 ) — 20 LENGTH 2r'-5 1/4" <br /> S TTAN K LEVE l ( D O N O T S L O P E ), � I}-Ir— OUTER DIA. 1D•_4• <br /> _ WEIGHT 4,170 LBS.(APPROX) <br /> ' I MAGNETOSTRICTIVE PROBE —I I _II I- -� <br /> VARIABLE LENGTH SUBMERSIBLE PUMP <br /> —III—III III— —I I ITL I II III <br /> ANNULUS (— <br /> LEAK DETECTOR SENSOR AT BOTTOM CENTER OF TANK <br /> CONTRACTOR TO FIELD CUT LOWER END OF FILL TUBE <br /> AT A 45' ANGLE & INSTALL PER MANUFACTURERS INSTRUCTIONS <br /> 21 '-5 1 /4" (10,000 GALLON TANK) 1 '-6" <br /> USE APPLICABLE SECTIONS ONLY <br /> T Y P I C A L P R O D U C T T A N K — E L E V A T 1 0 N <br /> 4 REV DATE REVISED S e° W'° APPROVALS 4 <br /> APPROVAL RECORD DRAWN B. RH <br /> UNION OIL OF CALIFORNIA, dba UNOCAL, 1994 WRESTONE DATE �PRN& <br /> PHIS DOCUMENT AND THE INFORMATION CONTAINED HEREIN IS ssueD FOR c.u.P. DIESEL FUEL <br /> PROPRIETARY TO UNION CIL OF CALIFORNIA (UNOCAL_) AND HAS CHECKED By UNDERGROUND FUEL TANK INSTALLATION <br /> BEEN FURNISHED IN CONFIDENCE AND ARE SUBJECT TO THE ISSUED FOR PLAN CHECK Rcwxa ° > DATE <br /> _ S OF PARATE SECRECY AGREEMENT BETWEEN UNOCAL <br /> MPROED <br /> AND THE RECIPIENT, THE RECIPIENT IS NOT TO COPY, DUPLICATE ISSUED FOR GEN. BID -. <br /> Oft DISCLOSE THE CONTENTS TO ANY PERSON OR ENTITY EXCEPT DATE 1/8/97 ss " ""`°0 °"^"""G NO, REV MO. <br /> 6 - <br /> AS EXPRE551_Y AUTHORIZED <br /> ISSUED FOR CONSTRUCT.ED BY SAID AGREEMENT OR BY UNOCAL scuF 3 4" - 1 ' <br /> IN WRITING, PRODUCTS COMPANY J 1 D <br /> RECORD DRAWING I ,�R wcn,mil <br />