My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1630
>
2300 - Underground Storage Tank Program
>
PR0518624
>
COMPLIANCE INFO 2013-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/11/2021 9:30:46 AM
Creation date
11/5/2018 11:18:45 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2015
RECORD_ID
PR0518624
PE
2371
FACILITY_ID
FA0024496
FACILITY_NAME
Costco Wholesale #38 (Gas Station)
STREET_NUMBER
1630
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95210
APN
09428011
CURRENT_STATUS
01
SITE_LOCATION
1630 E Hammer Ln
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HAMMER\1630\PR0518624\COMPLIANCE INFO 2013-2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
216
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• 0 Page 9 of 11 <br /> 8. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed By: ❑ Sump Manufacturer ®Industry Standard ❑ Professional Engineer <br /> ❑ Other(Specify) <br /> Test Method Used: ❑Pressure ❑ vacuum ® Hydrostatic <br /> ❑ Other(Specify) <br /> Test Equipment Used: See attached testing procedures Equipment Resolution: <br /> Fill Sump#87-1 Fill Sump#87-2 Fill Sump#91 Fill Sump#Additive <br /> Sump Diameter: <br /> Sump Depth: <br /> Height from Tank Top to Top of <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest <br /> Electrical Penetration: <br /> Condition of sump prior to <br /> testing: <br /> Portion of Sump Tested Above highest Above highest Above highest Above highest <br /> penetration penetration penetration penetration <br /> Sump Material&Manufacturer: <br /> Wait time between applying <br /> pressure/vacuum/water and 30 minutes 30 minutes 30 minutes 30 minutes <br /> starting test: <br /> Test Start Time: <br /> Initial Reading(RI): <br /> Test End Time: <br /> Final Reading(RF): <br /> Test Duration: 15 min 15 min 15 min 15 min <br /> Change in Reading(RF-Rt): <br /> Pass/Fail Threshold or Criteria: 0.002 0.002 0.002 0.002 <br /> Test Result: ❑ Pass Lj Fail ❑ Pass ❑Fail Pass Fail Lj Pass Lj Fail <br /> Is there a sensor in the sump? ®Yes ❑No ®Yes No ®Yes ❑No ® Yes ❑No <br /> Does the sensor alarm when <br /> either product or water is ❑Yes [-]No ®NA ❑Yes ❑No®NA ❑Yes❑No®NA ®Yes ❑No❑NA <br /> detected? <br /> Was sensor removed for testing? ®Yes ❑No ❑NA ®Yes ❑No❑NA ®Yes❑No❑NA ®Yes ❑No NA <br /> Was sensor properly replaced and ZYes [-]No ❑NA ®Yes ❑No❑NA Yes 0 NO ®Yes ❑No❑NA <br /> verified functional after testing? I I I NA <br /> Comments— (include information on repairs made prior to testing, and recommended follow-up forfailed tests) <br /> Fill Sumps not tested—brine fill <br />
The URL can be used to link to this page
Your browser does not support the video tag.