My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1999 - 2001
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARDING
>
16
>
2300 - Underground Storage Tank Program
>
PR0231136
>
COMPLIANCE INFO 1999 - 2001
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/4/2019 4:35:51 PM
Creation date
11/5/2018 11:27:29 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999 - 2001
RECORD_ID
PR0231136
PE
2361
FACILITY_ID
FA0003610
FACILITY_NAME
A&A GAS & FOOD MART
STREET_NUMBER
16
Direction
E
STREET_NAME
HARDING
STREET_TYPE
WAY
City
STOCKTON
Zip
95204
APN
13902001
CURRENT_STATUS
01
SITE_LOCATION
16 E HARDING WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
116
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ANL <br /> California Edition:June 2000 <br /> Marley Pump Co. <br /> Red Jacket ST 1401 L, ST 1801 L, CPT, ProLink <br /> AUTOMATIC ELECTRONIC LINE LEAK DETECTOR <br /> Certification: Leak rate of 3.0 gph with Po= 100%and PFA=0%. <br /> Leak rate of 0.2 gph with Po= 100%and PF,,=0%. <br /> Leak rate of 0.1 gph with Po=100%and PF,,=0%. <br /> Leak Threshold: 1.5 gph for leak rate of 3.0 gph. <br /> 0.1 gph for leak rate of 0.2 gph. <br /> 0.047 gph for leak rate of 0.1 gph. <br /> A pipeline system should not be declared tight if the test result indicates a loss that equals or <br /> exceeds this threshold. <br /> Applicability: Gasoline, diesel,aviation fuel,fuel oil#4, methanol, ethanol,gasoline blends with methanol and <br /> ethanol. <br /> Other liquids may be tested after consultation with the manufacturer. <br /> Specification: System tests pressurized fiberglass and steel pipelines. <br /> Tests are conducted at 10-25 psi for leak rate of 3.0 gph. <br /> Tests are conducted at operating pressure equivalent to 30 psi for leak rate of 0.2 gph. <br /> Tests are conducted at 10-20 psi for leak rate of 0.1 gph. <br /> Pipeline Capacity: Maximum of 172 gallons for leak rate of 3.0 gph. <br /> Maximum of 163 gallons for leak rates of 0.2 gph and 0.1 gph. <br /> Waiting Time: None between delivery and testing. <br /> None between dispensing and testing. <br /> Test Period: Response time is 2 to 4 minutes for leak rate of 3.0 gph. <br /> Response time is 2 minutes to 4 hours for leak rate of 0.2 gph. <br /> Response time is 4 minutes to 4 hours, 45 minutes for leak rate of 0.1 gph. <br /> Test data are acquired and recorded by a microprocessor. <br /> Calculations are automatically performed by the microprocessor. <br /> System Features: Permanent installation on pipeline. <br /> Automatic testing of pipeline. <br /> Preset threshold. <br /> Single test to determine if pipeline is leaking. <br /> Recording and display of day, date, and time of conclusive test. <br /> Pump shutdown, message display,and alarm activation if leak is declared. <br /> Calibration: System must be checked annually and calibrated if necessary in accordance with manufacturer's <br /> instructions. <br /> Comments: ST 1401 L is a combination of ST 1400 automatic tank gauge and the ST 1401 L automatic electronic <br /> line leak detector. <br /> ST 1801 L is a combination of ST 1800 automatic tank gauge and ST 1801 L automatic electronic line <br /> leak detector. <br /> CPT is an electronic line leak detector component. <br /> Prol-ink is either a stand alone electronic automatic line leak detector,or a combination of and <br /> automatic tank gauge and an automatic electronic line leak detector. <br /> Marley Pump Co. Evaluator: Ken Wilcox Associates <br /> 500 East 59th St., P.O. Box 3888 Tel: (816) 443-2494 <br /> Davenport, IA 52807 Date of Evaluation: 12/16/96, 01/31/97 <br /> Tel: (888) 262-7539 <br /> 124 <br /> Appearance on this list is not to be construed as an endorsement by any regulatory agency nor is it any guarantee of the performance of <br /> the method or equipment. Equipment should be installed and operated in accordance with all applicable laws and regulations. <br />