My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_1989
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BUCKLEY COVE
>
4950
>
2300 - Underground Storage Tank Program
>
PR0231028
>
INSTALL_1989
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/27/2022 10:54:08 AM
Creation date
11/5/2018 12:27:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1989
RECORD_ID
PR0231028
PE
2361
FACILITY_ID
FA0003811
FACILITY_NAME
RIVER POINT LANDING MARINA-RESORT*
STREET_NUMBER
4950
STREET_NAME
BUCKLEY COVE
STREET_TYPE
WAY
City
STOCKTON
Zip
95219
APN
11820001
CURRENT_STATUS
01
SITE_LOCATION
4950 BUCKLEY COVE WAY
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\B\BUCKLEY COVE\4950\PR0231028\INSTALLATION 1989 .PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> F <br /> initial repair should be limited to the exchange of X76S he alarm <br /> annunciator <br /> sun buzzer and module <br /> will indicate <br /> an alar 5 <br /> modules and verification of proper wiring of all y a leak. The X lashing will also indicate an <br /> incoming field connections. which tank has <br /> alarm should the cuter shell leak and allow ground <br /> 4.2 Annunciator Module water to seep into the tank. <br /> Troubleshooting of the annunciator module <br /> should be carried out systematically, since this <br /> module operates in conjunction with the <br /> X53-2000 Field Isolator and the intrinsically safe 7.0 SPECIFICATIONS <br /> 24 VDC power supply. <br /> In the event of a malfunction of this module, 7.1 System, Model X76S <br /> check field wiring to the input terminal connector Power: 115 VAC, 60HZ <br /> of the X53-2000 Field isolator (schematic Power Consumption: 100 VA <br /> X76-2001). Check fuse in the power supply and <br /> measure with a DC voltmeter the voltage across Operating Temperature: 32 to 165°F (0 to 75°C) <br /> the output of the power supply, confirming 21.6 Dimensions: <br /> to 30 VDC. 9 X 9.5 x 4.2 inches (22.86 x 24.13 X 10.67 cm) <br /> Replace the X53.2000 Field Isolator moduie. If Mounting: General purpose area; wall mount <br /> this does not solve the problem, the cause is in FhM1 Approved: Fife J.I. 2N4A1,AX <br /> the annunciator module, which will have to be <br /> replaced. 7.2 Annunciator Module <br /> Field Sensor: Dry contact <br /> Field Sensor Voltage: 115 VAC (suppiied <br /> 5.0 GENERAL SYSTEM DESCRIPTION by X76S) <br /> Number of inputs: One per module <br /> The Ronan Series X76S Leak Detector Monitor is FM Approved: File J.I. 2N4A1.AX . <br /> a four-point annunciator system of general-purpose <br /> design equipped with certified, intrinsically safe 7.3 Intrinsically Safe Field Sensor <br /> barriers to interface with field contacts that are Interface Module X53 <br /> located within a hazardous area as described in Number of In uts: Two per module <br /> section 1.0. The field contact, when transferring from p <br /> normally open or normally closed to its off-normal Sensors Voltage: 24 VDC, current limited <br /> state, will be visually indicated via the light-emitting Sensors: Dry contact <br /> diode and the audible buzzer will sound. The front <br /> panel-mounted pushbutton allows the operator to Output Interface to Alarm Module: Relay <br /> acknowledge the alarm, thereby changing the flashing contact; normally open/normally closed-, <br /> LED to steady-on and silencing the audible alarm. The selectable <br /> test pushbutton, if pressed, will actuate all alarm Power Consumption: 750 mW per input <br /> points to verify proper operation of the logic and the Supply Voltage: 24 VDC from IS power supply <br /> LEDs. <br /> <j> Approved: File J.I. 2N4A1.AX <br /> 7.4 Power Supply IS (Intrinsically Safe) <br /> .0 TYPICAL APPLICATION— Power Input: 115 VAC <br /> SECONDARY CONTAINMENT output Voltage: 24 VDC <br /> WANK LEAK MONITOR <�M >Approved: File J.1. 2N4A1.AX <br /> The Model X76S, used as a leak detector, 7.5 Vapor Sensor, Model HV <br /> monitors liquid levels in secondary underground tanks Detection Method: Solid-state diffusion type <br /> and/or ground wells. The system finds applications in <br /> Detectable Gases: Hydrocarbons, gasoline, <br /> gasoline and oil storage facilities to detect these leaks solvents, carbon monoxide, methane, ammonia, <br /> in time to prevent leakage or seepage of hazardous sulfur dioxide, hydrogen sulfide _ <br /> liquid into the underground water table. Detectable Range: 0.100% LEL <br /> The secondary containment tank leak monitor consists <br /> of liquid-level sensors and alarm annunciator modules, Accuracy: ±5% <br /> located in the Ronan X76S system. The liquiddevel Response Time: Less than 15 sec to 90% full <br /> sensor monitors the area between the inner and outer scale <br /> tank for possible spillage. Should a Beak occur, the Sensitivity: 5 m <br /> product will be contained in the outer shell and the y pp <br />
The URL can be used to link to this page
Your browser does not support the video tag.