Laserfiche WebLink
Sensor Lite: 5 years minimum 8.o SERIES X53 INTRINSICALLY <br /> Zero Drift: Less than 5% per year SAFE INTERFACE SYSTEM <br /> �-- operating Temperature: —40° to 165°F 8.1 Applications <br /> (-400to 75°C) The Series X53 Interface Chassis are designed <br /> Electrical Classification: Class I, Division 1, to handle the following functions associated with <br /> Groups B, C and D; hazardous atmosphere intrinsically safe annunciators and logic systems. <br /> Approved: File F100826 <br /> A method of accepting contact and transistor <br /> Cable Length: 25 feet; 3-conductor, number 20 switch inputs from the general-purpose area and <br /> AWG shielded-, max. length 3,000 feet providing an approved contact output, so that the <br /> output control signal can be incorporated into <br /> 7.6 Tank Leak Sensor, Model LS-3 the wiring to the approved intrinsically safe <br /> Housing: 304 stainless steel annunciators. EXAMPLE: Miscellaneous contacts <br /> from general-purpose devices in the control <br /> Switch: panel that are required to actuate alarm points in <br /> Type: Single pole, single throw N.C. an intrinsically safe annunciator. <br /> Rating: 10 VA, 110 to 240 VAC A method of accepting intrinsically safe input <br /> R Stem and float material. Fuel proof polysulfone contact signals from the hazardous area via an <br /> Operating Temperature: 0 to 225°F (-18 to approved barrier to provide output contacts that <br /> 107°C) can be used for operating general-purpose <br /> Pressure: 50 psi maximum annunciators or logic systems. <br /> Leads: 22 AWG <br /> lJ� Approved: File E867J7 A method of transmitting contact output signals <br /> + from either a general-purpose area or Class 1, <br /> Division 2 area to provide output contact signals <br /> 7.7 Tank Leak Sensor, Model LS 7 in intrinsically safe loops. EXAMPLE: <br /> For fiberglass tank. Miscellaneous contacts in remote �ovedlo tpets <br /> Housing Material: ABS that are required to provide an app <br /> contact for use in intrinsically safe loops. <br /> Mounting: "/z" NPT with %' THD and lock nut EXAMPLE: Isolation for contact switches that <br /> Pressure: 150 psig at 70°F (21°C) maximum require an interface to permit switching of field- <br /> Liquid SpG: .70 minimum powered, intrinsically safe loops. <br /> Switch: 8.2 Mechanical Features of Chassis <br /> Type:Single pole, single throw N.C. <br /> Input and output terminals are physically <br /> Rating: 10 VA, 110 to 240 VAC <br /> Leads: 22 AWG separated. <br /> Leads.- <br /> File E86797 The input terminal compartment has conduit <br /> knockouts, as do the output terminal <br /> 7.8 Reservoir Type Tank Leak Sensor,. <br /> compartments and power wiring input. <br /> Model LS-10 No passageways exist between the two compart- <br /> Reservoir: ments, so it is impossible to inadvertently <br /> Volume: Two gallons (7.57 liters) intermix the input and output wiring. <br /> Dimensions (height x width x depth): The below chassis printed circuits are designed <br /> 13 X 11 x 11 inches (33.02 x 27.94 x 27.94 cm) so that the input leads come from one end of the <br /> # Material: Polyethylene plastic printed circuit board connector and the output <br /> Switch: leads come from the other end. <br /> Type: Single pole, single throw <br /> Rating: 10 VA, 110 to 240 VAC 8.3 Special Installation Instructions <br /> Stem and float material: polysulfone Equipment and associated wiring approved as <br /> Operating Temperature., 0 to 225°F intrinsically safe may be installed in any The <br /> (-18 to 107°C) hazardous location for which it is approved. <br /> Pressure: 50 psi maximum provisions of Articles 500-517 of the National <br /> ' Leads: 22 AWG Electrical Code need not apply to such <br /> ll� Approved: File E86797 installations. <br /> The Ronan X53 Interface Chassis may be <br /> installed in a Class 1, Division 2 or non hazardous <br /> area. <br /> As the intrinsically safe portion of the system is <br /> made up of the field contacts and associated <br /> wiring, all field contact wiring is to be run in <br />