My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HOOD
>
5655
>
2300 - Underground Storage Tank Program
>
PR0540345
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/17/2021 2:44:41 PM
Creation date
11/5/2018 1:13:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0540345
PE
2351
FACILITY_ID
FA0023065
FACILITY_NAME
FedEx Ground - Tracy
STREET_NUMBER
5655
STREET_NAME
HOOD
STREET_TYPE
Way
City
Tracy
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
5655 Hood Way
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HOOD\5655\PR0540345\COMPLIANCE INFO 2016 - PRESENT.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
297
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County AM NED <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 1 61121 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> FedEx Ground-Tracy 5655 Hood Way, Tracy September 18,2017 <br /> UST System Observations <br /> 322 HSC 25281.6(a) Unburied below grade emergency generator system failed to meet exemption status o V o R o COS <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status o V OR o COS <br /> 324 CCR 2717.1(g) Tampered with red tag <br /> OV o R o COS <br /> 325 CCR 2717.1(1) Deposited petroleum into a red tagged UST o V OR o COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms o V OR o COS <br /> 327 CCR 2631.1 UST system not compatible with the substance stored o V OR o COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements o V OR o COS <br /> 329 HSC 25298 Failed to comply with permanent closure requirements o V o R o COS <br /> 330 CCR 2636(0(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system o V o R o COS <br /> Single-Walled Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve o V o R in COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed o V o R o COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) o V o R o COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) o V o R o COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documentation violation o V o R e COS <br /> 2030 See below Unlisted Operations/Maintenance violation Uv OR o COS <br /> 2060 See below Unlisted Design/Construction violation o V OR c COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 105 CCR 2632(d)(1)Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD.The section labeled"Under Dispenser <br /> Containment(UDC)Monitoring, UDC monitoring stops flow of product at dispenser is marked Yes,which should be <br /> marked No. In the section labeled, 'Pipe Monitoring is performed using the following method(s)"the leak sensor <br /> model indicated a 485 sensor, but the facility uses a 208 sensor. The section labeled,"Personnel Responsibilities" <br /> is not updated with the current person having responsibility.According to Kevin McTee, Ismael Ramirez is no longer <br /> the person with responsibility and the correct name of the first person having responsibility is Mark Hammett and not <br /> Matt Hammett.The monitoring plan must be uploaded to the California Environmental Reporting System(CERS). <br /> Immediately log into CERS,make the necessary changes, and submit for review by the EHD. <br /> This is a minor violation. <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> A site plan must be submitted identifying the locations where monitoring will be performed. Site plan does not show <br /> location of the monitoring panel.An accurate UST Monitoring Site Plan was not submitted. Immediately log into the <br /> California Environmental Reporting System (CERS)at http://Oers.calepa.ca.gov/and upload a copy of the UST <br /> Monitoring Site Plan. <br /> This is a repeat violation, Class ll. <br /> FA0023065 PRO540345 SC333 09/18/2017 <br /> EHD 23-01 Rev.09/22/16 Page 3 of 6 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.