Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department Z <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 L <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.siciov.orglehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name; Facility Address: Date: <br /> FedEx Ground Tracy 5655 Hood Way, Tracy September 18, 2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS 11,or MINOR-Notice to Comply) <br /> Item# <br /> Remarks <br /> 301 HSC 25292.1 UST system is not operated to prevent unauthorized release, including spills and overfills. <br /> Fuel piping and filters were observed outside UDC containment on UDC dispensers#1, #2,#3, and#4. The <br /> underground storage tank system shall be operated to prevent unauthorized releases. This issue was previously <br /> cited during the inspection on 0811112016. Immediately take all necessary action to prevent unauthorized releases. <br /> Air pocket inside the brine hose was found inside the Bio Blender sump indicating a lack of communication in the <br /> secondary containment. Liquid was found inside the Under Dispenser Containment(UDC)in UDC#1,#2,#3,#6, <br /> and#7 indicating a leak in the secondary containment. Liquid was found inside the Biodiesel Sump and the diesel <br /> #1 and#2 sumps indicating a leak in the secondary containment. Secondary containment shall be impervious to the <br /> liquid and vapor of the substance contained and constructed to prevent structural weakening as a result of contact <br /> with any hazardous substances released from the primary containment. <br /> Immediately contact a properly licensed, trained, and certified contractor to make repairs to the UST system under <br /> permit and inspection of the EHD. <br /> This is a repeat violation, Class Il. <br /> 305 HSC 25290.1(e)VPH monitoring of the interstitial spaces of the UST system is not maintained. <br /> An air gap in the brine hose from the brine reservoir was observed. Brine level is not high enough to reach the hose. <br /> The monitoring of the liquid level in the interstitial space shall be maintained so that a breach in the primary or <br /> secondary containment is detected before the hazardous substance is released into the environment. Correct <br /> immediately by having a properly licensed, trained, and certified contractor replace the failed component(s)with <br /> functional component(s)and obtain a permit within one business day from the EHD. If the failed component(s)can't <br /> be replaced immediately,there is a possibility that the Bio Diesel Blender UST system may be red tagged to prevent <br /> fuel inputs. <br /> This is a minor violation. <br /> 306 CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br /> The UDC brine sensors in UDC#7,#3,#2,#1, and#5 were all located at the lowest point in the brine reservoir and <br /> not located to detect a leak at the earliest opportunity. Monitoring equipment shall be maintained to be able to <br /> detect a leak at the earliest possible opportunity. The sensor was relocated further up the top of the brine levels in <br /> the brine filled sensor containment by the service technician. Ensure that all monitoring equipment is maintained to <br /> detect a leak at the earliest opportunity. <br /> This was corrected on site. <br /> This is a Class II violation. <br /> FA0023065 PRO540245 SC333 09118!2017 <br /> EHD 23-01 Rev.09/22116 Page 4 of 6 Underground Storage Tank Program CIR <br />