Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, Caiifornia 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.s ov.or /ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: tate: <br /> FedEx Ground-Tracy 5655 Hood Way, Tracy September 18, 2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 313 HSC 25290.1, 25290.2, 25291 Failure to construct, operate, and maintain primary containment as product-tight. <br /> The fuel pipe under dispenser#1 was observed weeping fuel. All primary containment for the UST system must be <br /> tight. Immediately have a properly licensed, trained, and certified contractor repair or replace the failed component <br /> under permit and inspection of the EHD. <br /> Several absorbent pads were observed under the fuel piping inside the bio diesel blend sump. <br /> This is a minor violation. <br /> 314 HSC 25290.1, 25290.2, 25291 Failed to have secondary containment or secondary containment not tight. <br /> Liquid was found inside the Under Dispenser Containment(UDC)in UDC#1,#2,#3,#6, and#7, the Bio diesel <br /> Sump and the diesel#1 and#2 sumps. Secondary containment shall be impervious to the liquid and vapor of the <br /> substance contained and constructed to prevent structural weakening as a result of contact with any hazardous <br /> substances released from the primary containment. Immediately contact a properly licensed,trained, and certified <br /> contractor to make repairs to the UST system under permit and inspection of the EHD. <br /> This is a minor violation. <br /> 316 HSC 25290.1(c3),25290.2(c3) Secondary containment not constructed to prevent water intrusion (after Jul 2003). <br /> Liquid was observed in the Under Dispenser sumps#1,#2,#3,#4,the bio diesel sump, Diesel 1 STP sump and 2 <br /> STP sump, and the Diesel#1 and#2 fill sumps. Secondary containment shall be constructed to prevent any water <br /> intrusion into the system by precipitation, infiltration, or surface runoff. Immediately remove this liquid, make a <br /> hazardous waste determination per Title 22 hazardous waste regulations, and manage accordingly. Immediately <br /> contact a properly licensed, trained, and certified contractor to address the water intrusion into all the sumps listed <br /> above under permit and inspection of the EHD. <br /> This is a minor violation. <br /> 318 CCR 2636(0(2) Leak detector failed to detect a 3.0 gph leak at 10 psi. <br /> The Diesel line leak detector failed to detect a leak when tested. All line leak detectors shall be capable of detecting <br /> a 3-gallon per hour leak at 10 psi. Immediately have a properly licensed, trained, and certified contractor repair or <br /> replace the failed leak detector(LG 113-x listed, if applicable)and obtain a permit within one business day from the <br /> EHD. If the failed leak detector can't be replaced immediately,there is a possibility that the Diesel UST system may <br /> be red tagged to prevent fuel inputs. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> An inspection checklist was provided to the facility operator via email on the day of the inspection.The EHD has <br /> written the complete report which replaces the initial checklist. Violation#301 and#305 has been added. <br /> This report is an addendum to the report issued for 09108120017. See report from 09/0812017 for previous <br /> violations. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> FA0023065 PRO540345 SC333 09118/2017 <br /> EHD 23-01 Rev_09122/16 Page 6 of 6 Underground Storage Tank Program O]R <br />