My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HOOD
>
5655
>
2300 - Underground Storage Tank Program
>
PR0540345
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/17/2021 2:44:41 PM
Creation date
11/5/2018 1:13:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0540345
PE
2351
FACILITY_ID
FA0023065
FACILITY_NAME
FedEx Ground - Tracy
STREET_NUMBER
5655
STREET_NAME
HOOD
STREET_TYPE
Way
City
Tracy
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
5655 Hood Way
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HOOD\5655\PR0540345\COMPLIANCE INFO 2016 - PRESENT.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
297
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
imGerttfrt-Ryax frac. Gni J (� <br /> 4 <br /> Appendix VI <br /> E 0 E117E D <br /> MONITORING SYSTEM CERTIFICATION DEC 21 2017 <br /> For Use By All Jurisdictions Within the Slate of Califomia <br /> Authority Cited: Chapter 6.7, Health and Safety Code;Chapter 16, Division 3, TE" ' <br /> Regulations � ALTH <br /> n F""n RTM E NT <br /> This fort must be used to document testing and servicing of monitoring equipment.A separate certificatlon or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work.A copy of this form must be provided to the tank system <br /> ownerloperator The ownerloperator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date <br /> A Generallnromtation <br /> Fac1ity Name: _Ryder 8392000 Bldg No.- <br /> x SlteAddress: 5655 Hood Way city Tracy Zip: 95377 <br /> Fau.•ty Contact Person. Contact Phone No. <br /> A <br /> Make/Model of Monitoring System: TLS-350 Date of TestinglServicing 11!1012017 <br /> B. Inventory of Equipment Tested)Certiried <br /> Check the appropriate boxes to indicate specific equipment Ins ecledfserviced: <br /> Tank ID: DSL Tank ID: <br /> ❑ in-Tank Gauging Probe. Model: ❑ In-Tank Gaug ng Probe Model <br /> 19 Annular Space or Vault Sensor. Model: ❑ Annular Space or Vault Sensor Model <br /> ❑ Piping Sump I Trench Serim(s). Model: ❑ Pip ng Sump I Trench Senscgs). Model <br /> ❑ F+n Sump Sensor(s) Model: ❑ Fill Sump Sensors) Model <br /> ❑ Mechanical Line Leak Detector Model: ❑ Mechanical Line Leak Detector Model <br /> IM Electron c L ne Leak Detector Model: PLLD ❑ Electronic Line Leak Detector Model <br /> ❑ Tank Overfill I High-Level Sensor. Model: ❑ Tank Overfil I High-Level Sensor Model <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify, u poll type and model in Section E on Page 2 <br /> Tank ID: Tank ID. <br /> ❑ In-Tank Gauging Probe Mode,: ❑ In-Tank Gauging Probe Moder <br /> E3.. Annular Space or Vault Sensor. Model: ❑ Annu'ar Space or Vault Senior Model <br /> ❑ Aping Sump I Trench Sensor(s). Model: ❑ Piping Sump/Tfench Sensor(s) Model <br /> ❑ Fill Sump Sensor(s) Model: ❑ Ri Sump Sensor(s) Model <br /> ❑ Mechan.cal Line Leak Detector. Model: © Mechanical Line Leak Detector Model <br /> ❑ Electronic Line Leak Detector Model E3 Electi lc Line Leak Detector Model <br /> ❑" Tank Overfill f High-Level Sensor Model ❑ Tank Overfi.I I High-Level Sensor Model <br /> ❑ Other(specify ui ment a and model In Section E on Page 2). ❑ Others equipment a and model in Section E on Pae 21. <br /> Dispenser ID; Dispenser Il <br /> ❑.. Dispenser Conta nmeru Sensors) Model ❑ Uspenser Containment Sensor(s) Mode. <br /> ❑ Shear Valves) ❑ Shear Valves) <br /> Q <br /> Oks,penser Containment Floats and Chain(s). ❑ Drspensw Containment Floats and Chain s <br /> Dispenser ID: Dispenser ID: <br /> ❑ Dispenser Containment Senszu(s) Model ❑ Dispenser Containment Sensors) Modell <br /> ❑" Shear Valves) © Shear Valve{s) <br /> 0 Dls eraser Containment Floats and Chains ❑ Di nser Contanment Floats and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> Q Dispenser Containment Sensor(s). Model ❑ Dispenser Containment Sensor(s) Moder <br /> ❑.. Shear Valve(s) ❑ Shear Vaive(s) <br /> ❑ Dispenser Conta nment Floats and Chains. ❑ D spenser Containment Floats and Chair <br /> if the facility contains more tanks or dispensers,copy this form Include informaUcin for every tank and dispenser at the facility <br /> C. Certification - I certify that the equipment identified In this document was inspected/serviced In accordance with the manufacturers` <br /> guidelines. Attached to this Certification Is Information (e.g. manufacturers' checkllsts) necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment For any equipment capable of generating such reports, I have also attached a <br /> copy of the report;(check all that apply): p System set-up p Alarm history report <br /> acL,ur w <br /> Technician Name(print) Alexander Tate Signature - - <br /> Cerlification No• 842662 License No 220793 <br /> Testing Company Name• Gettler-Ryan Inc. Phone No 925-551-7555 <br /> Testing Company Address 6805 Sierra Court#G, Dublin,CA 94568 Date of TeslinglServlcing <br /> Monitoring System Certification Page 1 of 4 12107 <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.