INSTALL_2015 AS BUILT PART 1
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HOOD
>
5655
>
2300 - Underground Storage Tank Program
>
PR0540345
>
INSTALL_2015 AS BUILT PART 1
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/19/2021 11:37:07 AM
Creation date
11/5/2018 1:21:05 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2015 AS BUILT PART 1
RECORD_ID
PR0540345
PE
2351
FACILITY_ID
FA0023065
FACILITY_NAME
FedEx Ground - Tracy
STREET_NUMBER
5655
STREET_NAME
HOOD
STREET_TYPE
Way
City
Tracy
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
5655 Hood Way
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HOOD\5655\PR0540345\2015 INSTALL\AS BUILT PART 1.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SITEPLAN SCALE: 1"= 30'-0" DETAILA- POWERINTEGRITYBOXDETAIL <br />y <br />SPACE REQUIRED ON <br />o WALL FOR FUEL POWER <br />PANEL & EQUIPMENT <br />REFER TO RACEWAY <br />M DETAILS TO MATCH <br />w CONDUIT LETTERS <br />(TYPICAL) <br />R J <br />O I I e NEW POWER INTEGRITY BOX, 2" CONDUIT TO H N P <br />LOW VOLTAGE DISCONNECT, & EXTERIOR RACEWAY <br />LINEHAUL OFFICE& CAMERA POWER SUPPLY ON NOTE: <br />CONTROL ROOM BUILDING INTERIOR BY FUEL G.C. IN BY SITE G.C., SEE <br />(SEE DETAIL A ON THIS SHEET) NO FORM OR TYPE OF CONDULET SHALL BE DETAIL BBELOW <br />31 <br />LINE HAUL OFFICE FUEL EQUIPMENT DESK 2" CONDUIT BYJ <br />'b— (SEE DETAILS C, D, & E ON THIS SHEET)- USEDAS A PULL BOX. DISTRIBUTION FUEL G.C. <br />I I CENTER LOAD WING A (s) 1" CONDUITS <br />LOCATION OF LEAK DETECTION CONSOLE BY FUEL G.C. POWER <br />(SEE DETAILS D & E ON THIS SHEET) C INTEGRITY BOX <br />(1) 2" & (5) V CONDUITS 60 0 30 60 <br />OVERHEAD TO POWER 2" PVC CONDUITS FOR POWER & (1) 1-1/2" <br />INTEGRITY BOX BY SITE G.C.; CONDUIT BE COATED RIGID METAL (ARC) <br />(' LL CONDUITS H, J, K, N,P & R IN ENTIRE LENGTH) WITH PULL STRINGS (LAST 10' 1 INCH = 30 FEET <br />(9) 1" CONDUITS OVERHEAD TO ADJACENT DETAILS AT BUILDING TO BE RIGID METAL) BELOW m <br />LINE HAUL OFFICE BY SITE G.C.; GROUND FOR ELECTRIC STUBBED TO FUEL <br />CONDUITS A, B, C, D, E, F, G, L & M FACILITY AREA & MARKED BY SITE G.C.; SEE <br />IN ADJACENT DETAILS `�i <br />SHEET E-2 FOR CONTINUATION OF CONDUITS <br />TRANSFORMER & DISCONNECT <br />SITE G.C. <br />LH02 <br />AT FUEL FACILITY <br />G.C. <br />u <br />NEW RACEWAY ON EXTERIOR <br />(4) 2" PVC CONDUITS FOR DATA WITH PULL <br />LZ <br />FOR FUELING CONTROLS, SHELVING, POWER, <br />WALL BY SITE G.C. <br />COVER FOR BIO -DIESEL ECONTROL <br />STRINGS (LAST 10' AT BUILDING TO BE RIGID <br />i <br />J <br />n <br />(SEE DETAIL B ON THIS SHEET) <br />4 <br />METAL) BELOW GROUND FOR ELECTRIC <br />(SEE DETAIL F ON THIS SHEET) <br />C <br />STUBBED TO FUEL FACILITY AREA & MARKED <br />Ifl <br />%N <br />G <br />N <br />` <br />BY SITE G.C.; SEE SHEET E-2 FOR <br />c <br />`E <br />OEXTER R OF DISTRB TIONY <br />CONTINUATION OF CONDUITS AT FUEL FACILITY <br />/gs <br />SSSS—SSSS <br />SS—SS—S9 <br />U <br />55 <br />ujod <br />—SS—SS—SS—SS—SS--------- <br />%� <br />e„o� <br />�d.o� B„01,s.T1 <br />V LONG x 18" W IDE SHELF BY <br />�A.0i <br />LU <br />5y �� <br />SITE G.C. <br />.ot <br />6d.01. <br />g <br />M"Z <br />M„Z M.Z M,.Z <br />Z—B <br />AS SHOWN <br />NN <br />/N ti <br />\ Ill <br />LL NN III <br />6” <br />G) LL NN III I <br />IId1\Ilry,\ I <br />NN <br />'FS <br />0 I NN <br />LL I <br />I \N '000, <br />I <br />� I - <br />D <br />4— <br />LL <br />OFI <br />' ICI <br />_ I 96WI <br />TRAILER <br />GARAGE � <br />i I <br />L IT EL 134.4 <br />DETAIL D - LINE HAUL GENERAL <br />PLAN VIEW SCALE: 1/4” = 1'-0" DETAIL E - LINE HAUL OFFICE EQUIPMENT LAYOUT SCALE: 1/2"= V-0" <br />V <br />o E V E A L LEAK DETECTION CONSOLE <br />K <br />OFFICE <br />TRANSFORMER & DISCONNECT <br />SITE G.C. <br />LH02 <br />120 AMP SERVICE FOR FUEL <br />G.C. <br />u <br />5 <br />FOR FUELING CONTROLS, SHELVING, POWER, <br />'n <br />COVER FOR BIO -DIESEL ECONTROL <br />AND DATA (SEE DETAIL C ON THIS SHEET) <br />i <br />J <br />n <br />LOCATION OF LEAK DETECTION CONSOLE <br />4 <br />Q <br />(SEE DETAIL F ON THIS SHEET) <br />C <br />m <br />Ifl <br />ON <br />c <br />`E <br />OEXTER R OF DISTRB TIONY <br />CENTE <br />BSITE ONDUITS <br />A6,C,DE,FG,L&M <br />SENSORS & GAU <br />OVERFILL & <br />POWER <br />�IDISPENSI <br />* DISTRIBUTION <br />SMALL PIE BOXY y <br />555 <br />LARGE PIE BOX — <br />PFIS IC <br />CONSOLE <br />MONITOR <br />POWER VAR <br />B10 -DIESEL <br />BLENDING UNIT <br />NOTES: <br />1. SEE SHEET E-3 FOR PEGASUS <br />INTERCONNECTION DIAGRAM. <br />2. ALL LOOSE WIRES SHALL BE NEATLY <br />BUNDLED WITH NYLON WIRE TIES. <br />3. VIDEO MONITORING SYSTEM <br />REQUIREMENTS TO BE DETERMINED & <br />COORDINATED WITH FedEx Gmund ON A <br />SITE SPECIFIC BASIS. <br />4. ALL WORK EXCEPT CONDUIT STUB -UP TO <br />BE BY FUEL G.C. <br />A <br />0 <br />I <br />I <br />I <br />I, <br />av <br />..ELECTRICAL PULL BOXES, "--- <br />SHEET E-4 FOR DETAILS; SEE <br />SHEET E-2 FOR CONTINUATIO <br />OF CONDUITS AT FUEL FACILI' <br />I <br />I <br />I <br />a � <br />a� <br />X 4' <br />•O <br />® -® o <br />NOTE: <br />NO FIELD SPLICES <br />ALLOWED, ONLY <br />CONTINOUS WIRE RUNS <br />THROUGH PULL BOXES. <br />1" CONDUIT <br />FROM PICO <br />BOX BY <br />FUEL G.C. <br />SCALE: 112"= V-0" <br />(5) 1" CONDUITS <br />TO EXTERIOR <br />RACEWAY BY <br />SITE G.C., SEE <br />DETAIL S BELOW <br />8'x8"x36" <br />PULL BOX BY <br />TRANSFORMER & DISCONNECT <br />SITE G.C. <br />(TO PROVIDE 120/ 208,3 -PHASE, <br />120 AMP SERVICE FOR FUEL <br />G.C. <br />PANEL) BY SITE G.C. <br />OUTLET SHALL BE <br />POWEREDFROM <br />EMERGENCY <br />STOPPED CIRCUIT, <br />BY FUEL G.C. <br />POWER INTEGRITY BOX (POWER <br />LOW PANEL), 810 -DIESEL RELAY BOX, &LOW <br />n TArr VOLTAGE DISCONNECT BY FUEL G.C. <br />T CAMERA <br />POWER <br />SUPPLY CABINET <br />SUPPLIED BY <br />OWNER& <br />INSTALLED BY <br />FUEL G.C. <br />DETAIL B - RACEWAY DETAIL SCALE: 1/2"= V-0" <br />REFER TO POWER INTEGRITY <br />BOX DETAIL TO MATCH <br />CONDUIT LETTER (TYPICAL) <br />PENETRATE INTO BUILDING— <br />ABOVE LINE OF DROP CEILING <br />(1) 2" & (5) V CONDUITS BY SITE G.C. <br />SEE DETAIL A ABOVE <br />8" x 8" RACEWAY BY SITE G.C. <br />(3) 2" PVC CONDUITS TO— <br />ELECTRICAL PULL BOXES NEAR <br />FUEL AREA FOR POWER BY <br />SITE G.C.; LAST 10' (AT <br />BUILDING) TO BE RIGID METAL <br />(1) 1-1/2" PVC COATED RIGID— <br />METAL CONDUIT (GRC) ENTIRE <br />LENGTH TO BIO -DIESEL <br />BLENDING SUMP BY SITE G.C. <br />NOTE: NOTE: <br />RACEWAYS & CONDUITS INSTALL PULL STRINGS <br />SHOWN ARE MOUNTED IN ALL CONDUITS. <br />ON EXTERIOR OF <br />DISTRIBUTION CENTER. <br />/C REFER TO DETAILS C & D TO MATCH <br />CONDUIT LETTERS (TYPICAL) <br />Im�lllllll <br />�lllw <br />(TO FUEL FACILITY) <br />DETAIL C - LINE HAUL OFFICE ELEVATION DETAIL <br />REFER TO RACEWAY DETAILS TO MATCH B <br />CONDUIT LETTERS (TYPICAL) <br />A <br />SITE G.C. TO EXTEND (9) V CONDUITS TO <br />EXTERIOR RACEWAY. SEE DETAIL B ABOVE <br />(9) V EMT CONDUIT TO T ABOVE DROP <br />CEILING BY SITE G.C. <br />4X4 JUNCTION BOX WITH BLANK COVER FOR - <br />VEEDER-ROOT DATA WIRING, BY SITE G.C. <br />JUNCTION BOX WITH BLANK COVER FOR — <br />VEEDER-ROOT POWER & 120 VOLT OVER <br />FILL ALARM CIRCUIT, BY SITE G.C. <br />120V DEDICATED 20 AMP CIRCUIT TO -, <br />JUNCTION BOX WITH SOLID COVER FOR <br />VEEDER-ROOT CONSOLE BY SITE G.C. <br />w j ry l GRADE <br />NOTE: <br />DEDICATED CIRCUIT WIRING & <br />NETWORK WIRING TO BE SUPPLIED <br />BY SITE G.C.; ALL OTHER WIRING BY <br />FUEL G.C. <br />(9) V RIGIDCONDUITS <br />OVERHEAD TO LINE HAUL <br />OFFICE FOR DATA BY SITE G.C., <br />SEE DETAIL C BELOW <br />12" x 8" INTRINSICALLY SAFE <br />RACEWAY BY SITE G.C. <br />I.S. <br />(4) 2" PVC CONDUITS TO <br />30 ELECTRICAL PULL BOXES <br />NEAR FUEL AREA FOR <br />DATA BY SITE G.C.; LAST <br />10' (AT BUILDING) TO BE <br />RIGID METAL <br />SCALE: 1/2" = P-0" <br />z <br />zoo mm <br />o¢a'eo <br />0�ww3 M< 8¢ <br />.Y0LL' <br />Nd <br />Z <br />®&_ <br />® Z <br />W <br />W <br />Z <br />®Z <br />W <br />LINE OF DROP CEILING H <br />J <br />LL <br />LL Km <br />ZZ� <br />JW LL <br />Q N U <br />LZ) >- <br />LQ <br />U)LIJ <br />N F <br />25 <br />(3) NETWORK CONNECTIONS <br /><Ita <br />FOR FUEL INSTALLED BY SITE <br />W <br />G.C. <br />4X4 JUNCTION BOX WITH BLANK <br />c <br />COVER FOR BIO -DIESEL ECONTROL <br />n <br />BLENDING UNIT WIRING, BY SITE G.C. <br />C <br />Q <br />C <br />m <br />n <br />EQUALLY SPACED 2" HOLES & <br />c <br />`E <br />GROMMETS BY SITE G.C. <br />e <br />U <br />z <br />zoo mm <br />o¢a'eo <br />0�ww3 M< 8¢ <br />.Y0LL' <br />Nd <br />Z <br />®&_ <br />® Z <br />W <br />W <br />Z <br />®Z <br />W <br />LINE OF DROP CEILING H <br />J <br />LL <br />LL Km <br />ZZ� <br />JW LL <br />Q N U <br />LZ) >- <br />LQ <br />U)LIJ <br />N F <br />25 <br />(3) NETWORK CONNECTIONS <br /><Ita <br />FOR FUEL INSTALLED BY SITE <br />W <br />G.C. <br />4X4 JUNCTION BOX WITH BLANK <br />COVER FOR BIO -DIESEL ECONTROL <br />0$ <br />BLENDING UNIT WIRING, BY SITE G.C. <br />C <br />Q <br />VW <br />1-4 1-4 6'LONG x 30"WIDE COUNTER WITH <br />EQUALLY SPACED 2" HOLES & <br />`E <br />GROMMETS BY SITE G.C. <br />e <br />U <br />ujod <br />J <br />=a <br />V LONG x 18" W IDE SHELF BY <br />LU <br />SITE G.C. <br />SCALE: <br />-4" <br />AS SHOWN <br />DRAWN BY: <br />4x4 JUNCTION BOX WITH BLANK COVER FOR <br />GLZ <br />CAMERA DATA/CO-AX BY SITE G.C. <br />DATE: <br />120V RECEPTACLE BY SITE G.C. <br />1/25/2015 <br />PROJECT NO. <br />4X4 JUNCTION BOX WITH BLANK COVER FOR <br />eFUELING DATA BY SITE G.C. <br />CA -1098 <br />120V RECEPTACLE WITH DEDICATED 20 <br />AMP CIRCUIT, BY SITE G.C. <br />DRAWING NO. <br />E-1 <br />