Laserfiche WebLink
CANOPY LIGHTING ELECTRICAL <br />PLAN & HAZARDOUS AREA PLAN <br />SCALE: 1/6"=1'-0" <br />HAZARDOUS AREA NOTES: <br />SYMBOLS: <br />REVISIONS <br />J <br />IN <br />J <br />J <br />D E F G <br />ALL CONDUIT ENTERING AND LEAVING THE CLASSIFIED/ HAZARDOUS AREAS SHALL <br />HAVE SEAL -OFFS PER N.E.C. 501.5(A) <br />CANOPY LIGHT FIXTURE <br />Eo <br />W <br />CANOPY OUTLINE <br />DISPENSING <br />AREA <br />� TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (UNDERGROUND TANK- FILL <br />ISLAND CAMERA DOME; MOUNT OVER 4" SQUARE BOX ON CANOPY Z PERLIN. <br />o <br />01 <br />N <br />- <br />OPENING) EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION: <br />N <br />ANY PIT, BOX, OR SPACE BELOW GRADE LEVEL, ANY PART OF WHICH IS WITHIN THE <br />EXACT LOCATION AS DIRECTED BY DIAMOND Z ENGINEERING INC. <br />m <br />DIVISION 1 OR 2 CLASSIFIED LOCATION. <br />LED CANOPY LIGHT FIXTURE. <br />EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION: <br />VEEDER ROOT OVERFILL ALARM HORN; MOUNT ON CANOPY COLUMN, <br />SUPPLIED BY OWNER (QTY: 20) <br />UP TO 18 INCHES ABOVE GRADE LEVEL WITHIN A HORIZONTAL RADIUS OF 10 FEET <br />FROM A LOOSE FILL CONNECTION AND WITHIN A HORIZONTAL RADIUS OF 5 FEET <br />TANK <br />FROM A TIGHT FILL CONNECTION. <br />Q' VEEDER ROOT OVERFILL ACKNOWLEDGMENT SWITCH; MOUNT ON CANOPY COLUMN <br />FILL <br />© TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (UNDERGROUND TANK- VENT <br />DISCHARGING UPWARD) EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION: <br />1800 VA, 277V HEAVY DUTY PHOTOCELL WITH WALL MOUNTING BRACKET. MOUNT <br />p <br />WITHIN 3 FEET OF OPEN END OF VENT, EXTENDING IN ALL DIRECTIONS, <br />ON CANOPY NEAR ROOF LINE OR AS SPECIFICALLY NOTED OTHERWISE. <br />O <br />O <br />O <br />EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION: <br />SPACE BETWEEN 3 FEET AND 5 FEET OF OPEN END OF VENT, EXTENDING IN ALL <br />♦�,�J <br />O O <br />O O <br />1.6 <br />DIRECTIONS. <br />CO TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (REMOTE PUMP -OUTDOORS) <br />EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION: <br />DO <br />ANY PIT, BOX, OR SPACE BELOW GRADE LEVEL IF ANY PART IS WITHIN A <br />F- <br />a <br />�\ <br />\ <br />y DEF y <br />0 0 <br />y DEF y <br />m y y <br />y <br />HORIZONTAL DISTANCE OF 10 FEET FROM ANY EDGE OF PUMP. <br />EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION: <br />WITHIN 3 FEET OR ANY EDGE OF PUMP, EXTENDING IN ALL DIRECTIONS. ALSO UP <br />o <br />¢ <br />w <br />¢ <br />w <br />r <br />3 <br />v <br />001 <br />m 'I m <br />0 o <br />m 2 m <br />0 <br />m m m Q <br />0 <br />m <br />o <br />m S <br />TO 18 INCHES ABOVE GRADE LEVEL WITHIN 10 FEET HORIZONTALLY FROM ANY <br />ow <br />Ow <br />SO <br />o <br />^' <br />EDGE OF PUMP. <br />w <br />> <br />w <br />> <br />a <br />, <br />D <br />m <br />OO <br /><9> TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE -PITS) <br />N <br />— <br />h <br />— <br />RD <br />SO <br />0 O <br />O O <br />EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION: <br />a <br />a <br />Q <br />a <br />v <br />O <br />y y <br />m 5/6 m <br />ENV <br />BOX <br />y y <br />o o <br />ANY PIT, BOX, OR SPACE BELOW GRADE LEVEL, ANY PART OF WHICH IS WITHIN THE <br />DIVISION 1 OR 2 CLASSIFIED LOCATION. <br />7/8 n' <br />N <br />N <br />© TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE - DISPENSER) <br />EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION: <br />SPACE CLASSIFICATION INSIDE THE DISPENSER ENCLOSURE IS COVERED IN <br />t3� <br />ANSI/UL 87, "POWER OPERATED DISPENSING DEVICES FOR PETROLEUM <br />-PRODUCTS." <br />O O <br />O O <br />O TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE - DISPENSER) <br />EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION: <br />4'-6" 4'-6" <br />-6" 4' <br />4'-6" 4'-6" O <br />WITHIN 18 INCHES HORIZONTALLY IN ALL DIRECTIONS EXTENDING TO GRADE <br />FROM (1) THE DISPENSER ENCLOSURE OR (2) THAT PORTION OF THE DISPENSER <br />©� <br />9' <br />9'-6" 9'-6" 9' <br />9'-6"� 9' S'4i" <br />ENCLOSURE CONTAINING LIQUID HANDLING COMPONENTS. <br />94, <br />© TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE - OUTDOOR) <br />EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION: <br />UP TO 18 INCHES ABOVE GRADE LEVEL WITHIN 20 FEET HORIZONTALLY OF ANY <br />EDGE OF ENCLOSURE. <br />�T <br />Y <br />O <br />NOTE: <br />REFER TO CANOPY <br />& <br />MANUFACTURER'S PLANS FOR IONS <br />ONEC <br />ACTUAL LIGHTING LAYOUT & <br />TWITH <br />Q <br />DIMENSIONS. <br />5 <br />z <br />z <br />UF �— <br />TURBINE C <br />w <br />SUMP <br />Lz—j¢i�o <br />w�pmm <br />N U, 'I <br />< a <br />ON jz$ <br /><� ZyQ <br />32.- B. <br />NO <br />z <br />00 <br />2z <br />NOTE: <br />0 0c <br />CONTRACTOR MUST <br />w <br />SUPPLY TITLE 24 <br />z <br />a <br />COMPLIANCE <br />z <br />0 <br />B REMOTE TANK <br />ACCEPTANCE FORMS. <br />w <br />VENTS <br />CAMERA MOUNTING DETAILS <br />SCALE: 1"=1'-0" <br />, <br />O <br />O <br />cn <br />INSTALL ONE GROUND LOOP <br />J <br />U ISOLATOR PER CAMERA; ISOLATOR <br />BE INSIDE JUNCTION BOX <br />€ <br />KTO <br />F£ <br />u� 612 WEATHER PROOF JUNCTION BOXr29 <br />FOR POWER 8 BELDEN 533945. <br />J O <br />LQL <br />Lu <br />Bs <br />U <br />y CONNECTIONS�9 <br />Q—Ky <br />$ <br />LINE OF CANOPY DECKING <br />y <br />J Q w 4 <br />p6 <br />a9 <br />CANOPY FASCIA <br />UE LL W Y <br />D>- <br />Za <br />ek <br />LINE HAUL CONTROL ROOM COMPONENTS <br />CAUTION STATEMENTS <br />NOTES: <br />MVERSHUB(TVP.) <br />CLOSED NIPPLE, <br />g <br />Q;4 <br />EUCHRE SIDES xUL waD <br />1. <br />THE E.C. SHALL BE RESPONSIBLE FOR INSTALLING ALL CABLING, CONDUIT <br />SEAL WITH PIPE <br />DOPE <br />_j <br />Ed H H <br />J <br />ao <br />� W <br />DAA A�� <br />MEOf LCO LnASTOR W6 SPEAN NLYY WTiED REFER OF ME UISTENCE <br />MEMO UNES, TRE <br />AND WIRING BETWEEN ALL REMOTE DEVICES. <br />WENEA� <br />L.L <br />9;: <br />PORI <br />DISTRIBUTION <br />R. <br />CCMRWOR SINLL BE LAMELY RESPONSIBLE FOR Yf AND PROM CBEN <br />OF Al NRGNNE_ ASSESSM x IRIS PROW CCNCEPoING MESE <br />,mow, <br />2. <br />FINAL CONNECTION TO ALL eFueling EQUIPMENT IN LINE HAUL <br />CANOPY GUTTER CAMERA <br />❑ <br />Q <br />e'" <br />_o <br />wrs DABLe <br />OPERATIONS OFFICE SHALL BE BY AN AUTHORIZED eFueling INSTALLER. <br />MOUNT CAMERA AS <br />w <br />ho <br />MNDEFLXWNO MUMS <br />CLOSE TO GUTTER <br />Z W <br />551 <br />a EMlERIU unDERE1Uux2 uNLI1R5 ARE MPPoNE OND <br />3. <br />FINAL SETUP, INSPECTION, PROGRAMMING AND START-UP OF FUEL <br />BOX AS POSSIBLE <br />Q <br />E` <br />HADLOODON1NOT ME <br />xnU nor BEER vEBmw. ME caHPAcr2e swt CEIFANNE rlc ErMcr <br />a AL UTUMS ROEMER SHOTS OR NOT Sxorm <br />MANAGEMENT SYSTEM SHALL BE THE RESPONSIBILITY OF THE FUEL G.C. <br />SIDE VIEW <br />^� <br />DISPENSER CRINO <br />L ESTER EM91NG <br />FENS TO CdWENEEMEM OF HIS RODF. ME CMIPACt. SHELL � <br />USING AN AUTHORIZED eFueling INSTALLER. <br />g <br />//� <br />FC DUAL CONFIS <br />9020.151w1: <br />CONRJMELY HSPONSIW Im NL 0SARS ". NEW BE OCG4CNED <br />BY RUAE TO EMMRx LOCATE MD PREBLRrE MT OND ALL <br />®T� <br />c J <br />CABLE NUMBERS <br />PCZ_DODO CAVR <br />MNDERYLWn2 OrILm¢. <br />4. <br />ALL eFueling EQUIPMENT SHOWN ON THIS DRAWING SHALL BE FURNISHED <br />y <br />�v$ <br />ce MFG CABLE <br />BY OWNER. <br />00 <br />Bsa <br />5. <br />WIRING SHOWN IS FOR A SIMULTANEOUS OPERATION OF MASTER AND <br />INSTALL ONE GROUND LOOP <br />�C2 <br />xz <br />sss <br />SATELLITE DISPENSERS. <br />w ISOLATOR PER CAMERA; ISOLATOR <br />�0 <br />ly <br />e <br />6. <br />CONDUITS MAV BE PVC EXCEPT FOR THE LAST tOL <br />TO BE INSIDE JUNCTION BOX (TYP.) <br />Q <br />Y4 . <br />Mai <br />PEcxsus uNn <br />55A <br />612 WEATHER PROOF JUNCTION BOX <br />$� <br />MBLL PIE BO <br />LARGE PIE Box <br />7. <br />ABOVEGROUND CONDUITS MAY BE EMT ABOVE IS A.F.F. INSIDE LINE HAUL <br />(TYP.) FOR POWER& BELDEN <br />krg <br />OFFICE. <br />U 533945 CONNECTIONS <br />e <br />_j_ <br />E <br />8. <br />TOTAL CONDUIT RUNS MUST BE LESS THAN OR EQUAL TO 1000 FEET PER <br />612 <br />SCALE: <br />INDIVIDUAL RUN. <br />I 4" _ LINE OF CANOPY DECKING <br />9. <br />SITE CONTRACTOR TO BRING CONDUITS WITHIN SOF THE FUEL ISLAND <br />AS SHOWN <br />S18 <br />WORK AREA. <br />DRAWN BY: <br />10. <br />ALL LIGHTING SHALL BE COMPLIANT WITH THE REQUIREMENTS OF 2013 <br />GLZ <br />I o a I <br />O <br />CEC 511.7.1.B1. <br />CLOSED MYERS HUB (TVP.) <br />NIPPLE (TVP.), <br />DATE: <br />BO EI <br />11. <br />LIGHTING IN CANOPY SHALL BE LABELED "SUITABLE FOR DAMP LOCATION" <br />SEAL WITH <br />PIPE DOPE CANOPY GUTTER BEYOND <br />1/25/2015 <br />PER 2013 CEC ART. 410.10 (A) & (B). <br />CAMERA (TYP.) <br />PROJECT NO. <br />CA -1098 <br />FRONT VIEW <br />. <br />EE -3 <br />