My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1998 - 2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
1111
>
2300 - Underground Storage Tank Program
>
PR0506724
>
COMPLIANCE INFO 1998 - 2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/20/2021 3:47:38 PM
Creation date
11/5/2018 3:25:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998 - 2007
RECORD_ID
PR0506724
PE
2361
FACILITY_ID
FA0007594
FACILITY_NAME
WINE COUNTRY STATION/7-ELEVEN
STREET_NUMBER
1111
Direction
E
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04931056
CURRENT_STATUS
01
SITE_LOCATION
1111 E KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\K\KETTLEMAN\1111\PR0506724\COMPLIANCE INFO 1998 - 2007.PDF
QuestysFileName
COMPLIANCE INFO 1998 - 2007
QuestysRecordDate
7/11/2018 4:26:40 PM
QuestysRecordID
3925819
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
207
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D. Results of Testing/Servicing <br /> Software Version Installed: <br /> Com lete the followin checklist: <br /> Yes ❑ No* Is the audible alarm o erational? <br /> Yes ❑ Na* Is the visual alarm a erational? <br /> es ❑ No* Were all sensors visualiins ected,function <br /> tested,and confirmed a erational? <br /> Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> not interfere with their Proper o eration? p <br /> ❑ Yes Q Na* if alarms are relayed to a remote monitoring station, is all communications equipment (E. modem)operational? g <br /> es ❑ No* For pressurized piping systems, does the turbine automatically shut clown if the Piping secondary containment <br /> L1 N/A monitoring system dctecls a leak, fails <br /> to t operate, or is electrically disconnected? If Yes: which sensors initiate <br /> Positive shut-down? (Check rill that apply) <br /> pl'Y) OML'iapr ❑ DispenserContainmentSensors. <br /> Did on confirm ositive shut-down due to leaks and sensor failure/disconnection? <br /> ------------- <br /> ❑ Yes ❑ No* For tank systems that 111ilize the inonijoring system as the primary tarok overfill warning device (i.e. no <br /> U'7Q7A mechanical overfill prevention valve is Installed}, is tlac overfill warning alarm visible and audible at the tank <br /> til! Dint{s)and o statin ro CFIY'? if SO, at what ercent of tank ca acit does the alarm trigger? <br /> D Yes* C3—ltTo Was any monitoring equipment replaced? If yes, identify specific sensors,probes, or other equipment replaced <br /> and list the manufacturer name and model for all replacement arts in Section E, below. <br /> 13—Yes* ElNo Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) ❑ <br /> Product; El Water. If es,describe causes in Section E,below. PP�'� <br /> Y U No* Was monitorin s stem set ureviewed to ensure proper set tin s?Attach set up reports,if applicable <br /> Yes ❑ No* Is all monitoring equipment - erational per manufacturer's specifications? <br /> *In Section E below,describe how and when these deficiencies were or will he corrected. <br /> E. Comments: o ,p <br /> R <br /> V <br /> Page 2 of 3 <br /> 03/01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.