ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998 - 2007
RECORD_ID
PR0506724
PE
2361
FACILITY_ID
FA0007594
FACILITY_NAME
WINE COUNTRY STATION/7-ELEVEN
STREET_NUMBER
1111
Direction
E
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04931056
CURRENT_STATUS
01
SITE_LOCATION
1111 E KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\K\KETTLEMAN\1111\PR0506724\COMPLIANCE INFO 1998 - 2007.PDF
QuestysFileName
COMPLIANCE INFO 1998 - 2007
QuestysRecordDate
7/11/2018 4:26:40 PM
QuestysRecordID
3925819
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
207
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SiteAdress: W�� �c_ v?-r _ t'f -z' ' �" '� hof D# Testing/Servicing: I I� <br /> F. In-Tank Gauging / Slit F;yuitrtnent: ❑ Check this box if tank,gauging is used only for inventory control. <br /> U Check this box if no tank gauging or SIR equipment is installed. <br /> This section must be completed ifin-tank gauging equipment is used to perform leak detection monitoring. <br /> Complete the following checklist: <br /> ❑ Yes ❑ No* Has all input wiring been inspected I-or proper entry and termination, including testing for ground faults? <br /> ❑ Yes ❑ No* Were all tank gauging probes vistally inspected for damage and residue buildup? <br /> ❑ Yes ❑ No* Was accuracy of system product level readings tested? <br /> ❑ Yes ❑ No* Was accuracy of system water level readings tested? <br /> ❑ Yes ❑ No* Were all probes reinstalled properly? <br /> ❑ Yes I ❑ No* I Were all items on the equipment manufactur'er`s maintenance checklist completed? <br /> * In the Section H, below, describe how and waren these deficiencies were or will be corrected. <br /> G. Line Leak Detectors (LLD): ❑ Check this box if[.L[)s are not installed. <br /> Complete the following checklist: <br /> U-1-es ❑ No* For equipment start-up or annual eelnipment certification, was a leak simulated to verify LLD performance? <br /> ❑ N/A (Check a//that appl,i) Simulated leak rate: C1177p.h.; G U.1 g.p.h ; ❑ 0.2 g.p.h. <br /> Yes ❑ No* Were all LLDs confirmed operational and accurate within regulatory requirements? <br /> es ❑ No* I Was the testing apparatus properly calibrated? <br /> Yes ❑ No* For mechanical LLDs,does the I.1-D restrict product flow if it detects a leak? <br /> ❑ N/A <br /> ❑ Yes ❑ No* For electronic LLDs,does the turbine automatically shut off if the LLD detects a leak? <br /> a <br /> ❑.Yes 17 No* For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled, <br /> 1 i /A or disconnected? <br /> ❑ Yes ❑ No* For electronic LLDs, sloes the turbine automatically shut off if any portion of the monitoring system <br /> U N/A malfunctions or fails a test? <br /> ❑ Yes ❑ No* For electronic IA,t)s, have all accessible wiring connections been visually inspected? <br /> CI"'N/A <br /> Ef Yes ❑ No* Were all items on the equipment rnnmrfacturer's maintenance checklist completed? <br /> * In the Section H, below,describe how and when Ilrese deficiencies were or will be corrected. <br /> H. Comments: <br /> Page 3 of 3 05/00 <br />