My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
140
>
2300 - Underground Storage Tank Program
>
PR0505687
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2022 12:02:27 PM
Creation date
11/5/2018 4:41:49 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0505687
PE
2361
FACILITY_ID
FA0006943
FACILITY_NAME
LATHROP GAS & FOOD INC
STREET_NUMBER
140
Direction
E
STREET_NAME
LATHROP
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19611007
CURRENT_STATUS
01
SITE_LOCATION
140 E LATHROP RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LATHROP\140\PR0505687\BILLING 2013 - 2015.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
103
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IFIED PROGRAM CONSOLIDATED FORNW <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN (Page 2 of 2) <br /> VI. UNDER DISPENSER CONTAINMENT(UDC)MONITORING <br /> 1. UDC MONITORING IS PERFORMED USING THE FOLLOWING METHOD 490-54. <br /> ❑ I.CONTINUOUS ELECTRONIC MONITORING Pd 2.FLOAT AND CHAIN ASSEMBLY 490-54b <br /> ❑ 4.NO DISPENSERS ❑ 3.ELECTRONIC STAND-ALONE <br /> _________—__________099.OTHER(Specify)_____—___ — ___ _ <br /> PANEL MANUFACTURER: � — _------ 0.90.-65 ------- ----'------- <br /> ___—__ �� J�/L�14,C 490-s6. <br /> LEAK SENSOR MANUFACTURER: r 0.90-57 ----S): .r__--------- <br /> o-CIt14 .N MODEL#((S): 490-58 <br /> DETECTION OF A LEAK INTO THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS 0 a YES ❑b.NO 491-19 <br /> UDC LEAK ALARM TRIGGERS AUTOMATIC PUMP SHUTDOWN ❑ a.YES ❑b.NO 490-60, <br /> FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a.YES ❑b.NO 490'61 <br /> UDC MONITORING STOPS THE FLOW OF PRODUCT AT THE DISPENSER. ❑ a YES ❑b.NO 490.62 <br /> 2.UDC CONSTRUCTION IS R.SINGLE-WALLED [12.DOUBLE-WALLED 490-63 <br /> IF DOUBLE WALLED: --49064e---- <br /> UDC INTERSTITIAL SPACE IS MONITORED BY: ❑ I.LIQUID—❑2.PRESSURE _❑3.VACUUM ____ <br /> A LEAK WITHIN THE SECONDARY CONENTTAMMOF THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS ❑a.YES ❑b NO <br /> --- 490-646 <br /> VII.PERIODIC SYSTEM TESTING <br /> ElI. ELD TESTING: THIS FACILITY HAS BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT ENHANCED 0.90.6-6. <br /> LEAK DETECTION(ELD)MUST BE PERFORMED. PERIODIC ELD IS PERFORMED EVERY 36 MONTHS AS R_EQUIRED_S23 CCR <br /> 2.SECONDARY CONTAINMENT COMPONENTS ARE TESTED EVERY 36 MONTHS. 490.66 <br /> 3.SPILL Bl1CKET5 ARE TESTED ANNUALLY. -------------"-------"------------------------------------ <br /> 490-61 <br /> VHI. RECORDKEEPING <br /> The following monitoring/maintenance records are kept for this facility: <br /> ER Alarm logs 490-68a [A Visual Inspection Records 490-68b El Tank integrity testing results 490-68c <br /> E]SIR testing results(and supporting documentation records). 49a6ad ❑ Tank gauging results(and supporting documentation records). 490-6ae <br /> El ATG Testing results(and supporting documentation records).49MEn' El Corrosion Protection 60-day logs 490-688 <br /> ❑Equipment maintenance and calibration records. 490-68h <br /> IX.TRAINING <br /> JR Personnel with UST monitoring responsibilities are familiar with all of the following documents relevant to theirjob duties. 491-690. <br /> REFERENCE DOCUMENTS MAINTAINED AT FACILITY(Check all that apply) <br /> © THIS UNDERGROUND STORAGE TANK MONITORING PLAN(Required)490-69b <br /> ® OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT(Required)490-6k <br /> E?J CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS 49049d <br /> &CALIFORNIA UNDERGROUND STORAGE TANK LAW 490-6% <br /> ❑ STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL AND <br /> STATISTICAL INVENTORY RECONCILIATION"490-697 <br /> ❑ SWRCB PUBLICATION:"UNDERSTANDING AUTOMATIC TANK GAUGING SYSTEMS"490.698 <br /> ❑ OTHER(Specify):m69q m69i <br /> This facility has a"Designated UST Operator"who has passed the California UST System Operator Exam administered by the International Code Council(ICC). <br /> The"Designated UST Operator"will[rain facility employees in the proper operation and maintenance of[he UST systems annually,and within 30 days of hire.This <br /> Vaining will include,but isnot limited[q[he following: <br /> ➢ Operation of[he UST systems in a manner consistent with the facility's best management practices <br /> ➢ The facility employee's role with regard[o lite monitoring equipment as specified in[his UST Monitoring Plan <br /> ➢ The facility employee's role with regard to spills and overfills as specified in the UST Response Plan <br /> ➢ Names of contact persons)for emergencies and monitoring alarms.490-10 <br /> X. COMMENTS/ADDITIONAL INFORMATION <br /> Provide additional comments here or indicate how many pages with additional information on specific monitoring procedures are attached to this plat 490-71 <br /> 0VFn-F1L�L_ PaEi./EtiTiaN is 5Cf Itr qf% CV1?A'n1 gj InF046A.'1(4-U Fu9f <br /> XI.PERSONNEL RESPONSIBILITIES <br /> The UST Owner/Operator is responsible for ensuring that: 1)the daily/routine UST monitoring activities and maintenance of UST leak detection equipment covered by <br /> this plan occurs,2)all conditions that indicate a possible release are investigated,and 3)all monitoring records are maintained properly. <br /> Th»�Elowin person(s)`are responsible for performing the monitoring and equipment main[ nanc <br /> 490-r2 TITLE ,Q )pF�l 4�r3 <br /> NAME Z S 490-74 TITLE r} L n <br /> The Designated Operator shall perform a monthly visual inspection of the facility, provide a report to the owner/operator, and inform the owner/operator <br /> conditions that need follow-up action. <br /> XII. OWNER/OPERATOR SIGNATURE <br /> CERTIFICATION: I certify that the information provided herein is true and accurate to the best of my knowledge. <br /> APP IGNATURE <br /> 490-76 DATE: �_a9aI1 <br /> �T.k Prazor 2.F 'lit wn r/O eralor 3.Au horized R r ntativ towner O. <br /> APPLICANT NAME(print): 490-78 APPLICANT TITLE: r�;a0o-79 <br /> MAT <br /> UPCF UST-D(12/2007)3/4 <br />