My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2014 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
140
>
2300 - Underground Storage Tank Program
>
PR0505687
>
COMPLIANCE INFO 2014 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2022 1:43:39 PM
Creation date
11/5/2018 4:43:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014 - 2015
RECORD_ID
PR0505687
PE
2361
FACILITY_ID
FA0006943
FACILITY_NAME
LATHROP GAS & FOOD INC
STREET_NUMBER
140
Direction
E
STREET_NAME
LATHROP
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19611007
CURRENT_STATUS
01
SITE_LOCATION
140 E LATHROP RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LATHROP\140\PR0505687\COMPLIANCE INFO 2014 - 2015.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
92
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br />Page of <br />7- UNDER -DISPENSER CONTAINMENT( 11130 TESTING <br />Test Method Developed By: ❑ UDC Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: ❑ Pressure ❑ Vacuum ®Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: Ineon Sump <br />Tester Equipment Resolution .002" <br />UDC #11-12 UDC # UDC #5-6 UDC #7-8 <br />UDC Manufacturer: <br />Bravo <br />UDC Material: <br />Steel <br />UDC Depth: <br />10" <br />Height from UDC Bottom to <br />Vertical, no <br />Top of Highest Piping <br />Horizontal <br />Penetration: <br />enetrations <br />Height from UDC Bottom to <br />Vertical, no <br />Lowest Electrical Penetration: <br />Horizontal <br />penetrations <br />Condition of UDC prior to <br />good <br />testing: <br />Portion of UDC Tested <br />6" from bottom <br />Does turbine shut down when <br />UDC sensor detects liquid {both <br />❑YesM No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑Yes❑ No ❑ NA <br />❑Yes❑ No ❑ NA <br />product and water)?* <br />Turbine shutdown response time <br />NA <br />NA <br />NA <br />NA <br />Is system programmed for fail- <br />®Yes❑ No ❑ NA <br />❑Yes❑ No ❑ NA <br />❑Yes[I No ❑ NA <br />❑Yes❑ No ❑ NA <br />safe shutdown?* <br />Was fail-safe verified to be <br />NO <br />o erationa]?* <br />Wait time between applying <br />30 mins <br />pressure/vacuum/water and <br />starting test <br />Test Start Time: <br />10:55 <br />Initial Reading (Rj): <br />2.949" <br />Test End Time: <br />11:10 <br />Final Reading (RF): <br />2.9486" <br />Test Duration: <br />15mins <br />Change in Reading (RF -R,): <br />0037" <br />Pass/Fail Threshold or Criteria: <br />.002" <br />Test Result: <br />Pass ❑ Fail <br />❑Pass ❑Fail <br />[:1Yass ❑Fail <br />El Pass L1 Fail <br />Was sensor removed for testing? <br />❑Yes❑ No 0NA <br />❑Yes❑ No ❑ NA <br />❑Yes❑ No ❑ NA <br />❑Yes❑ No ❑ NA <br />Was sensor property replaced <br />and verified functional after <br />[:]Yes[—] No ® NA <br />❑Yes❑ No E] NA <br />❑Yes❑ No Ll NA <br />❑Yes❑ No El NA <br />testing? <br />Comments — (include information on repairs made prior to testing, and recommendedfollow-up forfailed tests) <br />1 If the entire depth of the UDC is not tested, specify how much was tested. If the answer to Any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. <br />
The URL can be used to link to this page
Your browser does not support the video tag.