My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2014 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
140
>
2300 - Underground Storage Tank Program
>
PR0505687
>
COMPLIANCE INFO 2014 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2022 1:43:39 PM
Creation date
11/5/2018 4:43:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014 - 2015
RECORD_ID
PR0505687
PE
2361
FACILITY_ID
FA0006943
FACILITY_NAME
LATHROP GAS & FOOD INC
STREET_NUMBER
140
Direction
E
STREET_NAME
LATHROP
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19611007
CURRENT_STATUS
01
SITE_LOCATION
140 E LATHROP RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LATHROP\140\PR0505687\COMPLIANCE INFO 2014 - 2015.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
92
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br />6. PIPING SUMP TESTING <br />i <br />Page of <br />Test Method Developed By: ❑ Surop Manufacturer Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: ❑ Pressure ❑ Vacuum ®Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: Incon Sump Tester <br />Sump # Sump # <br />Sump Diameter: <br />Equipment Resolution: .002" <br />Sump # <br />Sump # <br />Swap Depth: <br />Sump Material: <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />Condition of sump prior to testing: <br />Portion of Sump Tested' <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />product and water)?` <br />❑ Yes❑ No ❑ NA <br />❑ Yes❑ No ❑ NA <br />❑ Yes❑ No ❑ NA <br />❑ Yes[_] No ❑ NA <br />Turbine shutdown response time <br />Is system programmed for fail-safe <br />shutdown? <br />Yes No NA <br />❑ ❑ ❑ <br />Yes No NA <br />❑ ❑ ❑ <br />❑ yes❑ No ❑ NA <br />❑ Yes <br />❑ No ❑ NA <br />Was fail-safe verified to be <br />operational?' <br />Yes NA <br />E]❑ No ❑ <br />❑ Yes[] No El NA <br />El Yes[] No E] NA <br />[_I Yes ❑ No [INA <br />Wait time between applying <br />pressure/vacuum/water and starting <br />test: <br />Test Start Time: <br />Initial Reading (Rj): <br />Test End Time: <br />Final Reading (RF): <br />Test Duration: <br />Change in Reading (RF -R,): <br />Pass[Fail Threshold or Criteria: <br />Test Result: <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Was sensor removed for testing? <br />❑ Yes❑ No❑NA <br />❑ Yes❑ No❑NA <br />❑ Yes[—] No❑NA <br />❑ Yes ❑ No❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />El Yes No❑NA <br />❑Yes❑ No[ -INA <br />❑ Yes❑ No❑NA <br />❑ Yes ❑ No❑ NA <br />Comments -- (include information on repairs made prior to testing, and recommended follow-up for.failed tests) <br />If the entire depth of the sump is not tested, specify how much was tested. If the answer to a� of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. <br />
The URL can be used to link to this page
Your browser does not support the video tag.