COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
192
>
2300 - Underground Storage Tank Program
>
PR0505867
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/8/2023 12:57:00 PM
Creation date
11/5/2018 4:45:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0505867
PE
2361
FACILITY_ID
FA0007059
STREET_NUMBER
192
STREET_NAME
LATHROP
STREET_TYPE
Rd
City
Lathrop
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
192 Lathrop Rd
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LATHROP\192\PR0505867\COMPLIANCE INFO 2016 - JUNE 2017.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
216
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITO%WG SYSTEM CERTIFI*TION <br />MAKE / MODEL OF MONITORING SYSTEM: Veeder-Root TLS -350 <br />CERTIFICATION /TEST DATE: January 4, 2017 <br />Al. FACILITY <br />A2. OWNER <br />Name Colonial Energy #40135 <br />Name Colonial Energy, LLC. <br />192 Lathrop Road, Lathrop, CA 95330 <br />Address 2860 N. Santiago Blvd. 2nd Floor, Orange, CA 92867 <br />Address <br />Phone# 209-858-4998 <br />Phone# 714-761-5426 <br />Contact Station Manager <br />Contact Victor Hassan <br />A4. TESTING CONTRACTOR <br />A3. C U P A <br />San Joaquin County Environmental Health <br />Name Walton Engineering, Inc. <br />Name <br />1868 E. Hazelton Avenue, Stockton, CA 95202 <br />Address P.O. Box 1025, W. Sacramento, CA 95691 <br />Address <br />Notified December 21, 2016 <br />Lic # 617238 A, B, Haz <br />Inspector Garrett Backus <br />Contact Veronica Freitas <br />Phone# 209-468-3442 <br />Phone# 916-373-1166 <br />B. INVENTORY OF EQUIPMENT TESTED/CERTIFIED (Check the appropriate boxes to indicate equipment inspected/serviced) <br />61: TANKS — <br />Tank#1 (Product): Gsaoline-87-1 <br />Tank#2 (Product): Gasoline -87-2 —� <br />❑ In -Tank Gauging Probe Model: <br />❑ In -Tank Gauging Probe Model: <br />0 Annular Space or Vault Sensor Model: 794390-060 <br />E Annular Space or Vault Sensor Model: 794390.460 <br />N Piping Sump / Trench Sensor(s) Model: 0794380-208 <br />0 Piping Sump / Trench Sensor(s) Model: 0794380-208 <br />0 Fill Sump Sensor(s) Model: 0794380-208 _ <br />0 Fill Sump Sensor(s) Model: 0794380-208_ _ <br />❑ Mechanical Line Leak Detector Model: _ <br />❑ Mechanical Line Leak Detector Model: _ <br />Electronic Line Leak Detector Model: 0848480-001 <br />❑ Tank Overfill I High -Level Sensor Model: <br />❑ Electronic Line Leak Detector Model: <br />❑ Tank Overfill I High -Level Sensor Model: _ <br />❑ Other (specify equipment in Section E) Model: <br />❑ Other (specify equipment in Section E) Madel: . <br />Tank #3 (Product): Gasoline -91 <br />Tank #4 (Product): Diesel <br />❑ In -Tank Gauging Probe Model: <br />❑ In -Tank Gauging Probe MotleC _ <br />Annular Space or Vault Sensor Model: 794390.460 <br />Annular Space or Vault Sensor Model: 794390-460 <br />0 Piping Sump / Trench Sensor(s) Model: 0794380-208 <br />Piping Sump I Trench Sensor(s) Model: 0794380-208 <br />0 Fill Sump Sensor(s) Model: 0794380-208 <br />❑ Mechanical Line Leak Detector Model: <br />Fill Sump Sensor(s) Model: 0794380-208 <br />❑ Mechanical Line Leak Detector Model: _ J <br />Electronic Line Leak Detector Model: 0848480-001 _ <br />Tank Overfill I High -Level Sensor Model: <br />Electronic Line Leak Detector Model: 0848480-001 JI <br />Tank Overfill / High -Level Sensor Model: <br />_ <br />E❑ <br />❑ Other equipment in Section E) Model: <br />Other (specify equipment in Section E) Model: <br />(specify <br />— <br />B2: DISPENSERSIUDC's <br />�� <br />Dispenser#: 1-2 <br />Dispenser #: 3-4 <br />0 Dispenser Containment Sensor(s) Model: 0794380-208 <br />0 Dispenser Containment Sensor(s) Model: _0794380-208 <br />M0 Shear Valves <br />0 Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) <br />❑ Dispenser Containment Float(s) and Chain(s) <br />7-8 <br />Dispenser#: 5-6 <br />Dispenser#: <br />Dispenser Containment Sensor(s) Model: 0794380.208 <br />0 Dispenser Containment Sensor(s) Model: 0794380-208 <br />Shear Valves <br />0 Shear Valves <br />❑ Dispenser Containment Float(s) and Chains) <br />❑ Dispenser Containment Float(s) and Chain(s) <br />Dispenser #: 11-12 <br />Dispenser #: 9-10 <br />E Dispenser Containment Sensor(s) Model: 0794380-208 _ _ <br />0 Dispenser Containment Sensor(s) Model: 0794380-208 J <br />Shear Valves <br />0 Shear Valves <br />El Dispenser Containment Float(s) and Chain(s) _ _j <br />❑ Dispenser Containment Float(s) and Chain(s) <br />_. _ <br />C. CERTIFICATION I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. <br />Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing th <br />layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report; (check all that apply <br />■ System set-up ■ Alarm History Report <br />WALTON ------ <br />Signature: Aj1-.., l�4�e"�'l�- ENGINEERING - INC. <br />January 4, 2017 <br />Technician I Cert #: Anthony Reyes 845115 8293772 Date: <br />0201'/ Walton Engineering, Inc. <br />