Laserfiche WebLink
�i <br />0 <br />FA0007059 PR0505e67 SCO01 01/04/2017 <br />EHD 23-01 Rev. 09/22/16 Page 3 of 4 Underground Storage Tank Program OR <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sioov.oro/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Colonial Energy CE 40135 (DBA Power Mart) <br />Facility Address: <br />1 192 Lathrop Rd, Lathrop <br />Date: <br />January 04, 2017 <br />322 <br />UST System Observations <br />HSC 25281.6(a) Unburied below grade emergency generator system failed to meet exemption status <br />o V o R o COS <br />323 <br />HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status <br />o V o R in COS <br />324 <br />CCR 2717.1(8) Tampered with red tag <br />o V o R o COS <br />325 <br />CCR 2717.1(n Deposited petroleum into a red tagged UST <br />o V o R o COS <br />326 <br />HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms <br />it V it R it COS <br />327 <br />CCR 2631.1 UST system not compatible with the substance stored <br />it V o R o COS <br />328 <br />HSC 25298 Failed to comply with temporary closure requirements <br />it V o R o COS <br />329 <br />HSC 25298 Failed to comply with permanent closure requirements <br />it V it R it COS <br />330 <br />CCR 2636(f)(6) Failure to meet all requirements in lieu of a line leak detector for emergency generatortank system <br />o V o R o COS <br />Single -Walled Non -Pressurized Piping <br />401 <br />CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve <br />o V c R o COS <br />402 <br />CCR 2643(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed <br />o V o R o COS <br />403 <br />CCR 2643(d) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1984) <br />n V o R o COS <br />404 <br />CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) <br />r V D R c COS <br />Other Violations <br />2010 <br />Sae below <br />Unlisted Administration/Documentation violation <br />o V o R c COS <br />2030 <br />Sae below <br />Unlisted Operations/Maintenance violation <br />o V o R o COS <br />2060 <br />See below <br />Unlisted Design/Construction violation <br />it V o R o COS <br />SUMMARY OF VIOLATIONS <br />(CLASS 1, CLASS 11, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />201 <br />CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions. <br />The UST system alarm logs for two alarms was not complete: <br />The C1, 87 octane, gross line fail, April 28, 2016 alarm was documented but did not include the year of the <br />correction. The date 4/29 was used without the year. <br />The L7, Diesel STP sump, fuel alarm, April 9, 2016 alarm was documented but did not include the year of the <br />correction. The date 4/11 was used without the year. <br />Document the complete date for alarms. <br />This is a minor violation. <br />211 <br />CCR 2715(f) Designated operator employee training not performed or log not kept. <br />The designated operator employee training was performed but the employee hire dates are not included on the the <br />training log. Please add the hire dates to the training log and submit a copy to the EHD. <br />This is a minor violation. <br />FA0007059 PR0505e67 SCO01 01/04/2017 <br />EHD 23-01 Rev. 09/22/16 Page 3 of 4 Underground Storage Tank Program OR <br />