MONITIMING SYSTEM CERTIF17CATION <br />LAN! 1 1 ?OiS <br />CERTIFICATION /TEST DATE: January5, 2016 <br />Al. FACILITY A2. OWNER <br />- <br />Name Colonial Energy #40135 Name Colonial Energy, LLC. <br />Address 192 Lathrop Road, Lathrop, CA 95330 Address 2860 N. Santiago Blvd. 2nd Floor, Orange, CA 92867 <br />Phone # 209-858-4998 Phone # 714-761-5426 <br />Contact Station Manager Contact Victor Hassan <br />D. RESULTS OF TESTING / SERVICING <br />Make / Model of Monitoring System: Veeder-Root TLS -350 SN# 80548678305001 <br />Software Version Installed: 327.04 <br />Complete the following checklist: <br />In Secilon t Delo W, describe now and When these deficiencies were or will be corrected. <br />Page 2 of 3 <br />■ Yes <br />❑ No ` <br />Is the audible alarm operational? <br />■ Yes <br />❑ No' <br />Is the visual alarm operational? <br />■ Yea <br />❑ No* <br />were all sensors visually Inspected, functionally tested, and confirmed operational? <br />■ Yes <br />❑ No* <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment <br />will not Interfere with their proper operation? <br />[:]Yes <br />❑ No* <br />■ N/A <br />H alarms are relayed to a remote monitoring station, is all communications equipment (e.g .modems) <br />operational? <br />■ Yes <br />■ Yes <br />❑ No ` <br />❑ N/A <br />❑ No • <br />For pressurized piping systems, does the turbine automatically shut down If the piping secondary containment <br />monitoring system detects a leak, falls to operate, or is electrically disconnected? If yes: which sensors initiate <br />positive shutdown? (check all that apply) ■ Sumpfrrench sensors; ■ Dispenser Containment Sensors. <br />Did you confirm positive shut -down due to leaks and sensor failure/tlisconnectkon? <br />❑ Yes <br />❑ No • <br />■ N/A <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br />mechanical overfill prevention valve is Installed), is the overfill warning alarm visible and audible at the tank <br />fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? _ <br />❑ Yes • <br />■ No <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced <br />and list the manufacturer name and model for all replacement parts In Section E, below. <br />■ Yes ` <br />❑ No <br />Was any liquid found Inside any secondary containment systems designed as dry systems? <br />(Check all that apply) ❑ Product; ■ Water. If yes, describe causes In Section E, below. <br />■ Yes <br />❑ No • <br />Was monitoring system set-up reviewed to Insure proper settings? Attach set-up reports, If applicable. <br />■ Yes ❑ No ` <br />Is all monitoring equipment operational per manufacturer's specifications? <br />In Secilon t Delo W, describe now and When these deficiencies were or will be corrected. <br />Page 2 of 3 <br />