Laserfiche WebLink
MONITORING SYSTEM CERTIFICATION <br /> CERTIFICATION / TEST DATE: January4, 2017 <br /> Al. FACILITY A2. OWNER <br /> Name Colonial Energy#40135 Name Colonial Energy, LLC. <br /> Address 192 Lathrop Road,Lathrop,CA 95330 Address 2860 N.Santiago Blvd.2nd Floor,Orange,CA 92867 <br /> Phone# 209-858-4998 Phone# 714-761-5426 <br /> Contact Station Manager Contact Victor Hassan <br /> D. RESULTS OF TESTING I SERVICING <br /> Make I Model of Monitoring System: Veeder-Root TLS-350 SN# 80548678305001 <br /> Software Version Installed: 327.04 <br /> Complete the following checklist: <br /> ■ Yes ❑ No* Is the audible alarm operational? <br /> ■ Yes ❑ No* Is the visual alarm operational? <br /> ■ Yes ❑ No* Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> ■ Yes ❑ No* Were all sensors Installed at lowest point of secondary containment and positioned so that other equipment <br /> will not Interfere with their proper operation? <br /> ❑ Yes ❑ Nc* If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.modems) <br /> ■ NIA operational? <br /> ■ Yes ❑ No* For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment <br /> ❑ NIA monitoring system detects a leak,fails to operate,or is electrically disconnected? If yes:which sensors initiate <br /> positive shutdown? (check all that apply) ■ Sump/Trench sensors; ■ Dispenser Containment Sensors. <br /> ■ Yes ❑ No* Did you confirm positive shutdown due to leaks and sensor failureldisconnection? <br /> ❑ Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.no <br /> ■ NIA mechanical overfill prevention valve is Installed),is the overfill Warning alarm visible and audible at the tank <br /> fill point(s)and operating properly? If so,at what percent of tank capacity does the alarm trigger? _ <br /> ■ Yes* ❑ No Was any monitoring equipment replaced? If yes,Identify specific sensors,probes,or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts In Section E,below. <br /> ■ Yes* ❑ No Was any liquid found Inside any secondary containment systems designed as dry systems? <br /> (Check all that apply) ❑ Product; ■ Water. If yes,describe causes in Section E,below. <br /> ■ Yes ❑ No* Was monitoring system set-up reviewed to Insure proper settings? Attach set-up reports,if applicable. <br /> ■ Yes ❑ No* Is all monitoring equipment operational per manufacturer's specifications? <br /> * In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. COMMENTS <br /> Removed a small amount of rainwater from all stp sumps. <br /> Replaced all tank annular sensors with 794390-460 sensor.Orignal(0794390320)were too short,and sensor was not reaching <br /> annular space bottom. <br /> Ste°" A <br /> ENVIRONMENTAL HEALTH <br /> DEPARTMENT <br /> ©2017 Walton Engineering,Inc. <br /> Page 2 of 3 <br />