Laserfiche WebLink
LINE LEA DETECTOR (LLD) TEDT REPORT <br />TEST DATE: January 7, 2015 <br />Al. FACILITY <br />A2. OWNER <br />January 7, 2015 <br />Name Tower Mart # 104 <br />Thomas Steiger A31060/8156310 <br />Name Tower Energy Group, Inc. <br />Date: <br />Address 192 Lathrop Road, Lathrop, CA <br />95330 <br />Address 1983 West 190th Street, Torrance, CA 90504 <br />Phone # 209-858-4998 <br />Phone # 916-285-7402 ext 100 <br />Contact Desiz Burns <br />Contact Mark Vasey <br />A3. C U P A <br />A4. TESTING CONTRACTOR <br />Name San Joaquin County Environmental <br />Health <br />Name Walton Engineering, Inc. <br />Address 1868 E. Hazelton Avenue, Stockton, CA 95202 <br />Address P.O. Box 1025, W. Sacramento, <br />CA 95691 <br />Notified Deecember 23, 2014 <br />Lic # 617238 A, B, Haz <br />Inspector Yes <br />Contact Veronica Freitas <br />Phone# 209-468-8257 <br />Phone# 916-373-1166 <br />I. LINE LEAK DETECTOR TEST RESULTS <br />Test <br />Equipment Used: <br />Vaporless VMI LDT-890 <br />Tank number - <br />- 1 <br />2 3 <br />4 <br />Product contained <br />Gasoline -87-1 <br />Gasoline -87-2 Gasoline -91 <br />Dlssel <br />Leak Detector Type <br />ELLD <br />ELLD <br />ELLD <br />Leak detector make model <br />0849480-001 <br />0949480-001 <br />eag8490.001 <br />Serial number <br />208852 <br />209154 <br />_ <br />209150 <br />Functional Element Holding (psi) <br />19 <br />19 <br />18 <br />Resiliency (ml) <br />55 <br />50 <br />_ <br />86 <br />Test leak rate (gph) <br />3.00 <br />3.00 <br />3.00 <br />t, Pump pressure (Psi) <br />38 <br />_ <br />38 <br />28 <br />Metering pressure (psi) <br />0 <br />0 <br />_ <br />0 <br />Pressure Restriction Reduction (psi) <br />38 <br />38 <br />28 <br />Length of Restriction Test (seconds) <br />0 <br />0 <br />0 <br />Full Flow Opening time (seconds) <br />0 <br />0 <br />_ _ <br />0 <br />PASS <br />PASS <br />TEST RESULT <br />PASS <br />Tank number <br />77 <br />Product contained <br />Leak Detector Type <br />Leak detector makelmodel <br />_ Serial number <br />Functional Element Holding (psi) <br />Resiliency (ml) <br />_ as as rate (gph) <br />- <br />Pump pressure (psi) <br />- -- <br />Metering pressure (psi) <br />- <br />- - <br />Pressure Restriction Reduction (psi) <br />Length of Restriction Test (seconds) <br />Full Flow Opening time (seconds) <br />TEST RESULT <br />C <br />J. COMMENTS: <br />Signature: <br />WALTON _ <br />,- <br />January 7, 2015 <br />Technician: <br />Thomas Steiger A31060/8156310 <br />Date: <br />