My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_1998
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LINDBERGH
>
6364
>
2300 - Underground Storage Tank Program
>
PR0507806
>
INSTALL_1998
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/23/2022 11:40:05 AM
Creation date
11/5/2018 5:11:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1998
RECORD_ID
PR0507806
PE
2361
FACILITY_ID
FA0007770
FACILITY_NAME
ATLANTIC AVIATION
STREET_NUMBER
6364
STREET_NAME
LINDBERGH
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
17726034
CURRENT_STATUS
02
SITE_LOCATION
6364 LINDBERGH ST 202
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LINDBERGH\6364\PR0507806\INSTALL 1998.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
99
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r• <br />19. Piping (cross-section* agram, including connections to tank and nsers). <br />(A) Vent and tank riser primary containment system equipped with overfill prevention system that: <br />_ Restricts delivery of flow to tank [Section 2635 (b) (2) (B) or (C)], or <br />Provide positive shut off of flow to the tank at no more than 95 % [Section 2635 (b)(2)(03, or <br />(g) Z� Vapor recovery piping designed so it cannot contain liquid phase product, or <br />(C) Suction piping (below grade piping operates at less than atmospheric pressure) [Section 2636 (a) (3)] <br />_ Sloped so contents of the pipe will drain back into the storage tank if the suction is <br />released. <br />_ No valves or pumps installed below grade. <br />_ Inspection method provided to demonstrate compliance with section 2636 (a) (3). <br />Corrodible underground piping protected against corrosion (Section 2636 (b)). <br />(E) ✓ Underground primary piping will meet all of the following requirements <br />Primary piping in contact with hazardous substance under normal operation conditions shall be: <br />installed inside a secondary containment system in the form of: ✓ secondary pipe Vault or <br />_lined trench to be sloped to a collection sump at the low point of the piping. <br />✓ Primary piping and secondary containment systems will be installed in accordance with industry <br />code of practice and voluntary consensus standards.. <br />_ Lined trench used as secondary containment <br />_ Material compatible with the substance stored. <br />_ Covered and capable of supporting any expected vehicular traffic. <br />(F) Underground piping with secondary containment will be equipped and monitored as follows: <br />_ Secondary containment will be equipped with a continuous monitoring system connected to an audible <br />and visual alarm system. <br />_✓ Automatic line leak detectors will be installed on pressurized piping <br />Manufacturer- y"—= r � M_ Model: T S P- ES <br />_ Annual monitoring will be conducted on the pressurized piping with secondary containment. <br />_ Annual Line tightness test will not be required if the continuous monitor shuts down the pump and <br />activates the alarm system when a release is detected and when the continuous monitoring system <br />fails or is disconnected. <br />20. _L�'/ State Water Resources Control Board "Facility (A)" and "Tank Permit (B)" application forms submitted. <br />21. '✓ Plan review and operating permit fees paid. <br />22. What is the approximate depth to ground water: <br />(include source of information - borehole logs, monitoring well data, water <br />studies, etc.) <br />23. _L�z Total number of tanks on site after installation: <br />24. _✓ County/City Fire District and Building Department notified. <br />25. in the event contamination is observed, confirmed or suspected as a result of a leaking UST system it is your <br />responsibility [in accordance with (CCR) Title 23, Division 3, Chapter 16, Article 11, Corrective Action <br />Requirements] as an owner or operator to submit a workplan to PHS-EHD Site Mitigation Unit prior to initiating any <br />assessment or remediation activities. For further assistance contact the Site Mitigation Unit at (209) 469-3450. <br />The owner or operator must acknowledge this responsibility for workplan submittal by signature and date below. <br />Name Title Date <br />CONDITIONS OF APPROVAL: <br />e <br />
The URL can be used to link to this page
Your browser does not support the video tag.