BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOOMIS
>
2973
>
2300 - Underground Storage Tank Program
>
PR0502828
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2021 10:24:35 PM
Creation date
11/5/2018 6:13:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0502828
PE
2381
FACILITY_ID
FA0005587
FACILITY_NAME
ED ROCHA LIVESTOCK TRANSPORT
STREET_NUMBER
2973
STREET_NAME
LOOMIS
STREET_TYPE
RD
City
STOCKTON
Zip
95205
CURRENT_STATUS
02
SITE_LOCATION
2973 LOOMIS RD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LOOMIS\2973\PR0502828\BILLING .PDF
QuestysFileName
BILLING
QuestysRecordDate
6/19/2017 11:19:08 PM
QuestysRecordID
3448322
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFO WATER RESOURCES CON OARD <br /> LAND GROUND STORAGE TANK PRO-GRAM <br /> FORM B . <br /> TANK PERMIT APPLICATION INFORMATION <br /> TANK <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANKI O <br /> 10 <br /> MARK ONLY ❑LW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANK <br /> ONE ITEM 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑6 TEMPP/OR�ARYTANK CLOSURE E] <br /> ❑8 TANK REMOVED N <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: �9 S /r-N'7 (i1� FARM TANK-YES❑ NO A <br /> W <br /> 1. TANK DESCRIPTIONOMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY O <br /> A. OWNERS TANK ID# B. MANUFACTURED BY: <br /> C. YEAR INSTALLED D. TANK CAPACITY IN GALLONS: O <br /> 11. TANK 9ONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. Tfl MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C_ ❑ 1 UNLEADED ❑ 2 LEADED ❑ 3 DIESEL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 4 OIL ❑ 1 ODUCT ❑ 4 GASAHOL n 5 JET FUEL ❑ 6 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑ 80 EMPTY ❑ 95 UNKNOWN `ZWASTE ❑ 7 METHANOL ;U�Y� 9999 OTHER(DESCRIBE IN ITEM 0,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> C.A.S #: <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# . <br /> Ill. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,8 D <br /> A.TYPE OF ❑ 1 OUBLEWALLED F--] 3 SINGLE WALLED WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM 2 SINGLEWALLED ❑4 SECONDARY CONTAINMENT ❑ 99 OTHER <br /> ❑ 1 STEGUIRON ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑ 5 CONCRETE ❑ 6 POLYVINYLCHLORIDE � 7 UMINUM ❑ 8100%METHANOL COMPATIBLE FAP <br /> ❑ <br /> MATERIAL rte/-/ <br /> 9 BRONZE 7110 GALVANIZED STEEL 95 UNKNOWN ❑ 99 OTHER <br /> ❑ 1 RUBBER LINED ❑ 2 ALKYD LINING ❑ 3 EPDXY LINING 4fHENOUCLINING <br /> C. INTERIOR ❑ 5 GLASS LINING ❑6 UNLINED 95 UNKNOWN <br /> LINING <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO ❑ 99 OTHER <br /> D.CORROSION ❑ 1 POLYETHLENEWRAP ❑ 2 TARORASPHALT ❑),VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE IV95 UNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDE ROUNOBOTH IF APPLICABLE <br /> A.SYSTEM TYPE AU 1 SUCTION A U 2 PRESSURE A GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLADW/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A695 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> olP S 1 VISUAL CHECK P S 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS P S 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE P S 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2 ESTIMATED QUANTITY OF 3, WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN <br /> GALLONS INERT MATERIAL? ❑YES ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED 8 SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# �URISDICTmON# AGENCY# FACILITY ID# TANK ID# <br /> YF-/FTI I ol oO <br /> CURRENT LOCAL AGENCY TY ID# APPROVED BY_NAME PHONE N WITH AREA CODE <br /> v' <br /> PERMIT NUMBER PERMIT APPROVAL DAT PEPERMIT EXPIRATION D E <br /> `OO <br /> CHECK N PERMIT AMOUNT SURCHARGE AMT. FEE CODE ECEIPT <br /> FORM B(6-29-88) THIS FORM MUST BE ACCOMPANIED BY A FACILITY/SITE APPLICATION, FORM 'A',UNLESS A CURRENT FORMA' HAS BEEN FILED <br /> 71) <br /> DATA PROCESSING COPY <br />