My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOOMIS
>
2973
>
2300 - Underground Storage Tank Program
>
PR0502828
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2021 10:24:35 PM
Creation date
11/5/2018 6:13:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0502828
PE
2381
FACILITY_ID
FA0005587
FACILITY_NAME
ED ROCHA LIVESTOCK TRANSPORT
STREET_NUMBER
2973
STREET_NAME
LOOMIS
STREET_TYPE
RD
City
STOCKTON
Zip
95205
CURRENT_STATUS
02
SITE_LOCATION
2973 LOOMIS RD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LOOMIS\2973\PR0502828\BILLING .PDF
QuestysFileName
BILLING
QuestysRecordDate
6/19/2017 11:19:08 PM
QuestysRecordID
3448322
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFO WATER RESOURCES COOARD :. <br /> FORM 'B': UND GROUND STORAGE TANK PRO RAM <br /> TANK TANK PERMIT APPLICATION INFORMATION <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. _ z <br /> 10 <br /> MARK ONLY ❑ 1 WPERMIT ❑ 3 RENEWALPERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLYC <br /> ONE ITEM 2 INTERIM PERMIT ❑4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: &OOM15S 64' FARMTANK-YES❑ NO 411b <br /> Ca <br /> I. TANKDESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY <br /> A. OWNERS TANK ID# 3 1 B. MANUFACTURED BY: vx/J <br /> C. YEAR INSTALLED (ISO D. TANK CAPACITY IN GALLONS: x 47 <br /> II. TANK PONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,5E2PLETE ITEM D. <br /> A. V 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUMe. C. 1 UNLEADED ❑2 LEADED ❑ 3 DIESEL <br /> F] 3 CHEMICAL PRODUCT ❑ 4 OIL PRODUCT ❑ 4 GASAHOL ❑5 JET FUEL ❑6 AVIATION GAS <br /> ❑5 HAZARDOUS ❑ 80 EMPTY ❑ 95 UNKNOWN ❑2 WASTE ❑ 7 METHANOL ❑99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A.B,C.&D <br /> A TYPE OF ❑ 1 UBLEWALLED ❑3 SINGLE WALLED WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM EV2 SINGLE WALLED ❑4 SECONDARYOONTAINMENT ❑ 99 OTHER <br /> ❑ 1 STEEL/IRON ❑ 2 STAINLESSSTEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD WFIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑5 CONCRETE ❑ 6 POLYVINYLCHLORIDE n 7/1LUMINUM E:] 8 100%METHANOL COMPATIBLE FRP <br /> MATERIAL IJnCJ�/ <br /> ❑9 BRONZE ❑ 10 GALVANIZED STEEL 95 UNKNOWN ❑99 OTHER <br /> 1 RUBBERUNED ❑2 ALKYD LINING ❑3 EPDXY LINING ENOLIC LINING <br /> C.INTERIOR,' 5 GLASS LINING 6 UNLINED 95 UNKNOWN <br /> LINING ❑ ❑ <br /> ❑ ISUNING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO ❑99 OTHER <br /> D.CORROSION ❑ I POLYETHLENEWRAP ❑2TAR OR ASPHALT ❑ 3 LWRAP ❑4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑5 CATHODIC PROTECTION ❑91 NONE IV95 UNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A SYSTEM TYPE a 0 I SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A B. CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASSPIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A }�6 CONCRETE A U 7 STEEL CLAD W/FRP A U B 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> n 8 1 VISUAL CHECK P S 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS P 8 4 ELECTRONIC MONITOR P 8 5 GROUND WATER MONITORING WELLS <br /> OI S 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE P S 95 UNKNOWN P 8 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? ElYES [:] NO <br /> THIS FORM HAS BEEN'COMPLPTED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED&SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> Eal = = 10 16; 1 If I lyl / I sq 10 10 1 C) AV <br /> CURRENT LOCAL AGENCY FACILITY ID x APPROVED BY NAME4PHONE# TH AREA CODE <br /> AC•/.'L//A/ <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERMIT EXPIRATION DATE <br /> CHECK# PERMIT AMOUNT SURCHARGE AMT. FEE CODE ECEIPT# BY: <br /> FORM B(6-29-88) THIS FORM MUST BE ACCOMPANIED BY A FACILITY/SITE APPLICATION, FORM 'A',UNLESS A CURRENT FORMA' HAS BEEN FILED <br /> DATA PROCESSING COPY 4- <br />
The URL can be used to link to this page
Your browser does not support the video tag.