My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011- 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
10878
>
2300 - Underground Storage Tank Program
>
PR0231598
>
COMPLIANCE INFO_2011- 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:12 PM
Creation date
11/5/2018 7:08:45 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011- 2015
RECORD_ID
PR0231598
PE
2361
FACILITY_ID
FA0001146
FACILITY_NAME
MORADA CHEVRON FAST N EASY #60*
STREET_NUMBER
10878
Direction
N
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95212
APN
08607002
CURRENT_STATUS
01
SITE_LOCATION
10878 N HWY 99 E
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\10878\PR0231598\COMPLIANCE INFO 2011- 2015 .PDF
QuestysFileName
COMPLIANCE INFO 2011- 2015
QuestysRecordDate
5/17/2017 4:55:05 PM
QuestysRecordID
3383937
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
242
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br />0 <br />Appendix VI <br />(Copies of Monitoring System Certification form and UST Monitoring Plot Pian available at http:llwww.walerboards.ca.gov.) <br />MONITORING SYSTEM CERTIFICATION <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of <br />Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for <br />each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br />ownerloperator. The ownerloperator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility Name: Morada Chevron Bldg. No.:#60 <br />Site Address: 10879 N. Hwy 99 City: Stockton Zip: 95212 <br />Facility Contact Person: Billal Contact Phone No.: (209)931.6154 <br />Make/Model of Monitoring System: Veeder-Root TLS -3508 Date of Testing/Servicing: 9113112 <br />Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicate specific equipment ins1 oected/serviced: <br />Tank ID: T1 -- 91 Super <br />Tank ID: T3 — 87 Regular <br />® In -Tank Gauging Probe, <br />Model: 846390-107 <br />® In -Tank Gauging Probe. <br />Model: 846390-107 <br />® Annular Space or Vault Sensor. <br />Model: 79439OD-420 (Split Tank) <br />Annular Space or Vault Sensor <br />ModeL 79439013-420 <br />Piping Sump l Trench Sensogs). <br />Model: 794380-206 <br />Piping Sump l Trench Sensor(s). <br />Model: 794380-208 <br />❑ Fill Sump Sensogs). <br />Model: <br />❑ Fill Sump Sensor(s). <br />ModeL <br />M Mechanical Line Leak Detector. <br />Model: Red Jacket <br />0 Mechanical Line Leak Detector. <br />Model: Red Jacket <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />® Tank Overfill I High -Level Sensor. <br />Model: Drop Tube Flapper Valve <br />R Tank Overfill I High -Level Sensor. <br />Model: Drop Tube Flapper Valve <br />❑ Other(specify equipment t e and model in Section E on Page 2). <br />© Others eci a quip ment ile and model in Section E on Pa2e 2), <br />Tank ID: T2 — 89 Plus <br />Tank ID: T4 - Diesel <br />In -Tank Gauging Probe. <br />Model: 846390-107 <br />❑ In -Tank Gauging Probe. <br />Model: 846390-107 <br />Annular Space or Vault Sensor. <br />Model: 79439OD-420 (Split Tank) <br />❑ Annular Space or Vault Sensor. <br />Model: 79439OD•420 (Split Tank) <br />Piping Sump/ Trench Sensor(s). <br />Model, 794380-208 <br />❑ Piping Sump 1 Trench Sensor(s), <br />Model: 794380-208 <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensogs). <br />Model: <br />lZ Mechanical Line Leak Detector, <br />Model: VMI <br />M Mechanical Line Leak Detector. <br />Model: fled Jacket <br />❑ Etectronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Mode$: <br />M Tank Overfill I High -Level Sensor. <br />Model: Drop Tube Flapper Valve <br />® Tank Overfill I High -Level Sensor. <br />Model: Drop Tube Flapper Valve <br />❑ Other(specify equipment a and model in Section E on Page 2), <br />❑ Other(specify equipment t e and model in Section E on Pa e 2). <br />Dispenser ID: 1-2 <br />Dispenser ID: 3-4 <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />® Shear Valve(s). <br />® Shear Valve(s). <br />® Dispenser Containment Float(s) and Chain(s). <br />0 Dispenser Containment Ftoat s and <br />Chain(s). <br />Dispenser ID: 5-6 <br />Dispenser ID: 7-8 <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />L] Dispenser Containment Sensor(s)- <br />Model: <br />® Shear Valve(s). <br />® Shear Valve(s). <br />0 Dispenser Containment Floats and Chains . <br />® Dis enser Containment Floats and <br />Chain(s). <br />Dispensertp: <br />Dispenser ID: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Dispenser Containment Sensor(s). <br />Model <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑ Dispenser Containment Floats and Chains <br />❑ Dispenser Containment Floa s and Chain(s). <br />'If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced In accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct <br />and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a <br />copy of the report; (check all that apply): E Syste et -up 2 Alarm history report <br />Technician Name (print): Ronnie Lewis Signature: <br />Certification No.: A26833 License. No.: 949066 <br />Testing Company Name: Nucleus Pump Services Phone No.:(530) 644-8465 <br />Testing Company Address: 4960 Pine Tree Ln Poilock Pines, Ca 995726 Date of Testing/Servicing- 911all 2 <br />Monitoring System Certification Page 1 of 4 12107 <br />2121107 <br />
The URL can be used to link to this page
Your browser does not support the video tag.